Quick facts
| Availability | Confirmed on request |
| Category | Advanced Diagnostics |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KT-MB-GT2AD.FF be shipped?
KT-MB-GT2AD.FF is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KT-MB-GT2AD.FF in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KT-MB-GT2AD.FF and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KT-MB-GT2AD.FF, subject to availability and destination.
Diagnostic Gateway Kit. Diagnostic gateway kit with Ethernet, FF-H1 interface for advanced diagnostics, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA, International, Europe, Device coupler location: non-explosion hazardous area<BR>Zone 2 - high-power trunk<BR>Zone 1 - high-power trunk<BR>Division 2 - high-power trunk<BR>Division 1 - high-power trunk. Design / Mounting: Motherboard based. Installation in hazardous area: Zone 2 / Div. 2. Rated voltage: 19.2 ... 35 V DC SELV/PELV. Rated current: 160 ... 90 mA. Power dissipation: max. 3.1 W. Number of segments: 4. Fieldbus type: FOUNDATION Fieldbus. Physical layer profile: profile type 114. ITK version: 6. Implementation: resource block 1x RSfunction block 4x MDI, 1x MDO, 1x MAI, 1x DItransducer block 16x ADM TB, 1x IO TB. Firmware update: Ethernet. Polarity: polarity-sensitive. Rated voltage: 9 ... 35 V. Rated current: 0 mA. Port: 100 BASE-TX. Protocol: TCP/IP and UDP/IP. Services: ICMP , DHCP , AutoIP , HTTP. Connection type: RJ-45 socket, 8-pin. Transfer rate: 100 MBit/s. Number of Diagnostic Bus Channels: 2. Number of Diagnostic Modules/Channel: 31 Using Ethernet Interface , 8 Using Fieldbus Interface. Termination: integrated. Cable length/Channel: 30 m. LED ERR: red: Hardware fault. LED PWR: green: Power on. LINK/ACT: yellow. CH1, CH2: yellow: diagnostic bus activity. Output I: alarm output diagnostic bus channel 1 , volt-free contact , NC contact. Voltage: 50 V DC. Current: max. 1 A. Output II: alarm output diagnostic bus channel 2 , volt-free contact , NC contact. Voltage: 50 V DC. Current: max. 1 A. Output III: common alarm , volt-free contact , NC contact. Voltage: 50 V DC. Current: max. 1 A. All circuits/FE: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Output I, II/other circuits: functional insulation acc. to IEC 62103, rated insulation voltage 250 Veff. Ethernet/Supply: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Ethernet/other circuits: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Fieldbus/other circuits: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Diagnostic Bus/other circuits: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Electromagnetic compatibility: . Directive 2014/30/EU: EN 61326-1:2013. Galvanic isolation: IEC 62103. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Climatic conditions: DIN IEC 721. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ethernet: IEEE 802.3. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F) hazardous area -40 ... 70 °C (-40 ... 158 °F) safe area horizontal DIN rail mounting. Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: < 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Pollution degree: max. 2, according to IEC 60664. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Housing material: Polycarbonate. Degree of protection: IP20. Mass: 470 g. Dimensions: . Height: see dimensions. Width: see dimensions. Depth: see dimensions. Mounting: DIN rail mounting. Certificate: TÜV 14 ATEX 115980 X. Marking: II 3 G Ex ec IIC T4 Gc. Directive conformity: . Directive 2014/34/EU: EN 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-7:2015+A1:2018. IECEx approval: IECEx TUN 14.0003X. Approved for: Ex ec IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Motherboard based |
| Installation in hazardous area | Zone 2 / Div. 2 |
Supply
| Rated voltage | 19.2 ... 35 V DC SELV/PELV |
| Rated current | 160 ... 90 mA |
| Power dissipation | max. 3.1 W |
Fieldbus connection
| Number of segments | 4 |
| Fieldbus type | FOUNDATION Fieldbus |
| Physical layer profile | profile type 114 |
| ITK version | 6 |
| Implementation | resource block 1x RSfunction block 4x MDI, 1x MDO, 1x MAI, 1x DItransducer block 16x ADM TB, 1x IO TB |
| Firmware update | Ethernet |
| Polarity | polarity-sensitive |
| Rated voltage | 9 ... 35 V |
| Rated current | 0 mA |
Ethernet Interface
| Port | 100 BASE-TX |
| Protocol | TCP/IP and UDP/IP |
| Services | ICMP , DHCP , AutoIP , HTTP |
| Connection type | RJ-45 socket, 8-pin |
| Transfer rate | 100 MBit/s |
Diagnostic Bus
| Number of Diagnostic Bus Channels | 2 |
| Number of Diagnostic Modules/Channel | 31 Using Ethernet Interface , 8 Using Fieldbus Interface |
| Termination | integrated |
| Cable length/Channel | 30 m |
Indicators/operating means
| LED ERR | red: Hardware fault |
| LED PWR | green: Power on |
| LINK/ACT | yellow |
| CH1, CH2 | yellow: diagnostic bus activity |
Outputs
| Output I | alarm output diagnostic bus channel 1 , volt-free contact , NC contact |
| Voltage | 50 V DC |
| Current | max. 1 A |
| Output II | alarm output diagnostic bus channel 2 , volt-free contact , NC contact |
| Voltage | 50 V DC |
| Current | max. 1 A |
| Output III | common alarm , volt-free contact , NC contact |
| Voltage | 50 V DC |
| Current | max. 1 A |
Galvanic isolation
| All circuits/FE | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Output I, II/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 250 Veff |
| Ethernet/Supply | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Ethernet/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Fieldbus/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Diagnostic Bus/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity
| Galvanic isolation | IEC 62103 |
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Fieldbus standard | IEC 61158-2 |
| Climatic conditions | DIN IEC 721 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Ethernet | IEEE 802.3 |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) hazardous area -40 ... 70 °C (-40 ... 158 °F) safe area horizontal DIN rail mounting |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | < 95 % non-condensing |
| Shock resistance | 15 g 11 ms |
| Vibration resistance | 1 g , 10 ... 150 Hz |
| Pollution degree | max. 2, according to IEC 60664 |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Housing material | Polycarbonate |
| Degree of protection | IP20 |
| Mass | 470 g |
| Dimensions | |
| Height | see dimensions |
| Width | see dimensions |
| Depth | see dimensions |
| Mounting | DIN rail mounting |
Data for application in connection with hazardous areas
| Certificate | TÜV 14 ATEX 115980 X |
| Marking | II 3 G Ex ec IIC T4 Gc |
| Directive conformity | |
| Directive 2014/34/EU | EN 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-7:2015+A1:2018 |
International approvals
| IECEx approval | IECEx TUN 14.0003X |
| Approved for | Ex ec IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |