Pepperl Fuchs KFU8-FSSP-1.D-Y322444
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Signal Converters |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KFU8-FSSP-1.D-Y322444 be shipped?
KFU8-FSSP-1.D-Y322444 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFU8-FSSP-1.D-Y322444 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFU8-FSSP-1.D-Y322444 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFU8-FSSP-1.D-Y322444, subject to availability and destination.
Frequency voltage current converter. Limit frequency 40 kHz, Voltage or current ouptput, Incrementing output
(Spacing factor 1 ... 9999), 2-, 3-, 4-wire sensors and rotary encoder can be connected, Auxiliary power output for sensors, Rated voltage: 20 ... 30 V DC, Connection: terminals 7+, 13- sensor supply
terminals 14, 15 NPN/PNP input (galvanically isolated), Analog voltage output: 0 ... 10 V DC; 2 ... 10 V DC; 30 mA max.; resolution: 12 mV; R i ≅ 330 Ω (terminal 5+, 6-). MTTFd: 100 a. Rated voltage: 20 ... 30 V DC. Fusing: external fusing 4 A. Power consumption: < 5 W. Type: 4-digit, 7-segment red display, 7 mm digit height. Display interval: 0.002 ... 9999 Hz or0.01 ... 9999 min-1. Parameter assignment: keypad-driven menu. Switching point: high: 16 ... 30 V DC; max.10 mA; Ri ≅ 3 kOhmlow: 0 ... 6 V DC. Connection: terminals 7+, 13- sensor supplyterminals 14, 15 NPN/PNP input (galvanically isolated). Connectable sensor types: 2-, 3-, or 4-wire proximity sensors and incremental rotary encoder. Sensor supply: Rated voltage - 1.5 V non-stabilised; ≤ 30 mA short-circuit protected. Analog voltage output: 0 ... 10 V DC; 2 ... 10 V DC; 30 mA max.; resolution: 12 mV; Ri ≅ 330 Ω (terminal 5+, 6-). Analog current output: 0 ... 20 mA; 4 ... 20 mA; resolution: 25 µA; Ri ≤ 600 Ω (terminal 4-, 5+). Digital incrementing: ≥ (Ub -3 V), 20 mA, short-circuit proof (Terminals 1-, 2+) with frequency division Fin /1 ... Fin /9999. Input frequency: ≤ 40000 Hz, pulse pause/pulse length: ≥ 12 µs. Deviation: ≤ 0.2 % of full-scale value. Changing interval: 5 ms (Internal processing time). Electromagnetic compatibility: EN 61000-6-2:2005 EN 61000-6-4:2007+A1:2011 EN 61326-1:2013. Ambient temperature: -25 ... 40 °C (-13 ... 104 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: max. 80 %, not condensing. Altitude: 0 ... 2000 m. Operating conditions: The device has only to be used in an indoor area.. Connection assembly: Caution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device.. Degree of protection: IP20. Connection: removable terminals , max. core cross section 0.2 mm2 ... 2.5 mm2. Construction type: modular terminal housing in Makrolon, System KF For use in the switch cabinet/switch cabinet module. Mounting: snap-on to 35 mm standard rail or screw fixing
Specifications
Functional safety related parameters
| MTTFd | 100 a |
Supply
| Rated voltage | 20 ... 30 V DC Ur |
| Fusing | external fusing 4 A |
| Power consumption | < 5 W |
Indicators/operating means
| Type | 4-digit, 7-segment red display, 7 mm digit height |
| Display interval | 0.002 ... 9999 Hz or0.01 ... 9999 min-1 |
| Parameter assignment | keypad-driven menu |
Input 2
| Switching point | high: 16 ... 30 V DC; max.10 mA; Ri ≅ 3 kOhmlow: 0 ... 6 V DC |
| Connection | terminals 7+, 13- sensor supplyterminals 14, 15 NPN/PNP input (galvanically isolated) |
| Connectable sensor types | 2-, 3-, or 4-wire proximity sensors and incremental rotary encoder |
| Sensor supply | Rated voltage - 1.5 V non-stabilised; ≤ 30 mA short-circuit protected |
Output
| Analog voltage output | 0 ... 10 V DC; 2 ... 10 V DC; 30 mA max.; resolution: 12 mV; Ri ≅ 330 Ω (terminal 5+, 6-) |
| Analog current output | 0 ... 20 mA; 4 ... 20 mA; resolution: 25 µA; Ri ≤ 600 Ω (terminal 4-, 5+) |
| Digital incrementing | ≥ (Ub -3 V), 20 mA, short-circuit proof (Terminals 1-, 2+) with frequency division Fin /1 ... Fin /9999 |
Transfer characteristics
| Input frequency | ≤ 40000 Hz, pulse pause/pulse length: ≥ 12 µs |
| Deviation | ≤ 0.2 % of full-scale value |
| Changing interval | 5 ms (Internal processing time) |
Standard conformity
| Electromagnetic compatibility | EN 61000-6-2:2005 EN 61000-6-4:2007+A1:2011 EN 61326-1:2013 |
Ambient conditions
| Ambient temperature | -25 ... 40 °C (-13 ... 104 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | max. 80 %, not condensing |
| Altitude | 0 ... 2000 m |
| Operating conditions | The device has only to be used in an indoor area. |
Mechanical specifications
| Connection assembly | Caution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device. |
| Degree of protection | IP20 |
| Connection | removable terminals , max. core cross section 0.2 mm2 ... 2.5 mm2 |
| Construction type | modular terminal housing in Makrolon, System KF For use in the switch cabinet/switch cabinet module |
| Mounting | snap-on to 35 mm standard rail or screw fixing |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs KFD2-WAC2-1.D – Strain Gauge Converter. 1-channel signal conditioner
Available on requestPepperl Fuchs KFD2-WAC2-Ex1.D – Strain Gauge Converter. 1-channel isolated barrier
Available on requestPepperl Fuchs KFU8-DW-1.D
Available on requestPepperl Fuchs KFU8-DWB-1.D
Available on requestPepperl Fuchs KFU8-GUT-1.D – Temperature Converter with Trip Values. 1-channel signal…
Available on requestPepperl Fuchs KFU8-GUT-Ex1.D – Temperature Converter with Trip Values. 1-channel isolated…
Available on requestPepperl Fuchs KFU8-SR-1.3L.V – Switch Amplifier, Timer Relay. 1-channel signal conditioner
Available on requestPepperl Fuchs KFU8-SR-Ex1.W – Switch Amplifier. 1-channel isolated barrier