Available on request

Pepperl Fuchs KFD2-RSH-1.2D.FL3

MPN: KFD2-RSH-1.2D.FL3 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryK-System (DIN Rail Mounting, Highly Functional)
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can KFD2-RSH-1.2D.FL3 be shipped?

KFD2-RSH-1.2D.FL3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFD2-RSH-1.2D.FL3 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFD2-RSH-1.2D.FL3 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-RSH-1.2D.FL3, subject to availability and destination.

Relay Module. 1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Up to PL e acc. to EN/ISO 13849, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, DTS function (de-energized to safe), Safety Integrity Level (SIL): SIL 3. Signal type: Digital Output. Safety Integrity Level (SIL): SIL 3. Systematic capability (SC): SC 3. Performance level (PL): PL e. Connection: Power Rail or terminals 14+, 15-. Rated voltage: 19 ... 26.4 V DC. Input current: max. 35 mA at 24 V DC , max. 44 mA at 19 V DC , with enabled internal fault detection. Power consumption: < 1.7 W , includes the power consumption of the digital input , see derating curves. Connection side: control side. Connection: terminals 7+, 8-. Pulse/Pause ratio: min. 150 ms / min. 150 ms with disabled internal fault detection min. 1 s / min. 1 s with enabled internal fault detection. Test pulse length: max. 2 ms from DO card. Signal level: 0-signal: -5 ... 5 V DC 1-signal: 19 ... 26.4 V DC. Rated current: 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card). Inrush current: < 200 mA after 100 µs. Connection side: field side. Connection: external voltage : terminals 4+/L, 5+/L, 2-/N load : terminals 6, 3. Connectable voltage: 50 ... 230 V AC 60 ... 110 V DC. Power dissipation: < 3.3 W at 5 A , see derating curves. Contact loading: 253 V AC/5 A/cos φ 0.7; 30 V DC/5 A resistive load , see derating curves. Minimum switch current: 10 mA. Mechanical life: 5 x 106 switching cycles. Line fault detection: low voltage < 35 V AC undercurrent: 10 mA AC; overcurrent: 5.5 A AC (relay energized) breakage: 48 kΩ; short-circuit: 29 Ω (load, relay de-energized). Fuse rating: 2.5 A (scope of delivery)max. 5 AT, recommended maximum utilization of the fuse: 80 %. Connection: terminals 10, 11. Contact loading: 30 V DC/ 0.5 A resistive load. Reaction time: < 2 s. Mechanical life: 105 switching cycles. Switching frequency: < 3 Hz with disabled internal fault detection < 0.5 Hz with enabled internal fault detection. Input/power supply: basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff. Input/fault indication output: basic insulation according to IEC/EN 61010-1, rated insulation voltage 30 Veff. Output/other circuits: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Display elements: LEDs. Control elements: DIP switch. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Low voltage: . Directive 2014/35/EUEN 61010-1:2010: . Directive 2014/35/EU: EN 61010-1:2010. Machinery Directive: . Directive 2006/42/ECEN 62061:2005+AC:2010+A1:2013+A2:2015 , EN/ISO 13849-1:2015: . Directive 2006/42/EC: EN 62061:2005+AC:2010+A1:2013+A2:2015 , EN/ISO 13849-1:2015. Electromagnetic compatibility: NE 21:2017 , IEC/EN 61326-3-2:2018 , EN 61326-3-1:2017. Degree of protection: IEC 60529:2013. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating.. Degree of protection: IP20. Connection: screw terminals. Mass: approx. 142 g. Dimensions: 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Signal typeDigital Output

Functional safety related parameters

Safety Integrity Level (SIL)SIL 3
Systematic capability (SC)SC 3
Performance level (PL)PL e

Supply

ConnectionPower Rail or terminals 14+, 15-
Rated voltage19 ... 26.4 V DC Ur
Input currentmax. 35 mA at 24 V DC , max. 44 mA at 19 V DC , with enabled internal fault detection
Power consumption< 1.7 W , includes the power consumption of the digital input , see derating curves

Input

Connection sidecontrol side
Connectionterminals 7+, 8-
Pulse/Pause ratiomin. 150 ms / min. 150 ms with disabled internal fault detection min. 1 s / min. 1 s with enabled internal fault detection
Test pulse lengthmax. 2 ms from DO card
Signal level0-signal: -5 ... 5 V DC 1-signal: 19 ... 26.4 V DC
Rated current0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card) Ir
Inrush current< 200 mA after 100 µs

Output

Connection sidefield side
Connectionexternal voltage : terminals 4+/L, 5+/L, 2-/N load : terminals 6, 3
Connectable voltage50 ... 230 V AC 60 ... 110 V DC
Power dissipation< 3.3 W at 5 A , see derating curves
Contact loading253 V AC/5 A/cos φ 0.7; 30 V DC/5 A resistive load , see derating curves
Minimum switch current10 mA
Mechanical life5 x 106 switching cycles
Line fault detectionlow voltage < 35 V AC undercurrent: 10 mA AC; overcurrent: 5.5 A AC (relay energized) breakage: 48 kΩ; short-circuit: 29 Ω (load, relay de-energized)
Fuse rating2.5 A (scope of delivery)max. 5 AT, recommended maximum utilization of the fuse: 80 %

Fault indication output

Connectionterminals 10, 11
Contact loading30 V DC/ 0.5 A resistive load
Reaction time< 2 s
Mechanical life105 switching cycles

Transfer characteristics

Switching frequency< 3 Hz with disabled internal fault detection < 0.5 Hz with enabled internal fault detection

Galvanic isolation

Input/power supplybasic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff
Input/fault indication outputbasic insulation according to IEC/EN 61010-1, rated insulation voltage 30 Veff
Output/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLEDs
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations) Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EUEN 61010-1:2010 Directive 2014/35/EU
Directive 2014/35/EUEN 61010-1:2010
Machinery Directive
Directive 2006/42/ECEN 62061:2005+AC:2010+A1:2013+A2:2015 , EN/ISO 13849-1:2015 Directive 2006/42/EC
Directive 2006/42/ECEN 62061:2005+AC:2010+A1:2013+A2:2015 , EN/ISO 13849-1:2015

Conformity

Electromagnetic compatibilityNE 21:2017 , IEC/EN 61326-3-2:2018 , EN 61326-3-1:2017
Degree of protectionIEC 60529:2013

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating.

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 142 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote