Pepperl Fuchs KFD2-HLC-Ex1.D
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | K-System |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KFD2-HLC-Ex1.D be shipped?
KFD2-HLC-Ex1.D is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD2-HLC-Ex1.D in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD2-HLC-Ex1.D and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-HLC-Ex1.D, subject to availability and destination.
HART Loop Converter. 1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as signal splitter (1 input and several outputs), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad, Housing width: 40 mm, Number of channels: 1-channel, HART communication, Trip relay, Rated voltage: 19 ... 30 V DC, Function: transmitter supply, Field device: 3-wire transmitter, Field device [2]: active sources, Signal: HART. Signal type: Analog input. Connection: Power Rail or terminals 23+, 24-. Rated voltage: 19 ... 30 V DC. Rated current: approx. 120 mA at 24 V DC. Power dissipation: 2.3 W. Power consumption: 2.9 W. Conformity: HART field device input (revision 5 to 7). Programming interface: programming socket. Connection side: field side. Connection: terminals 1, 2, 3, 4, 5, 6. Open circuit voltage/short-circuit current: typ. 24 V / 28 mA. Input resistance: 250 Ω , 5 % (terminals 2, 3 and with jumper on 5, 6). Available voltage: ≥ 15.5 V at 20 mA, short-circuit protected. Connection side: control side. Connection: output I: terminals 7, 8, 9 , output II: terminals 13, 14, 15 , output III: terminals 19, 20, 21. Output signal: analog. Voltage range: 5 ... 30 V , sink mode from external supply. Current range: 4 ... 20 mA , (source or sink mode). Load: max. 650 Ω , source mode. Fault signal: downscale I ≤ 2 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) or hold measurement value. Other outputs: HART communicator on terminals 22, 24. Collective error message: Power Rail and LED red. Output I, II, III: . Resolutionmax. 2 µAAccuracy< 20 µA, 10 µA typ.Influence of ambient temperature< ± 2 µA/KDuration of measurement/Response delayHART message acquisition time plus 100 ms: . Resolution: max. 2 µA. Accuracy: < 20 µA, 10 µA typ.. Influence of ambient temperature: < ± 2 µA/K. Duration of measurement/Response delay: HART message acquisition time plus 100 ms. Output I/II/III/power supply: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Display elements: LEDs , display. Control elements: Control panel. Configuration: via operating buttons via PACTware. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Low voltage: . Directive 2014/35/EUEN 61010-1:2010: . Directive 2014/35/EU: EN 61010-1:2010. Electromagnetic compatibility: NE 21:2006. Degree of protection: IEC 60529:2001. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Degree of protection: IP20. Connection: screw terminals. Mass: 300 g. Dimensions: 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: BASEEFA 07 ATEX 0174. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC. Supply: . Maximum safe voltageUm253 V AC (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 253 V AC (Attention! The rated voltage can be lower.). Equipment: terminals 1, 4/3 (with link between terminals 4 and 5). VoltageUo25.2 VCurrentIo104.9 mAPowerPo0.661 WInternal capacitanceCi1.1 nFInternal inductanceLi0 mH: Uo. Voltage: 25.2 V. Current: 104.9 mA. Power: 0.661 W. Internal capacitance: 1.1 nF. Internal inductance: 0 mH. Equipment: terminals 2, 5/3. VoltageUi< 28 VPowerPi< 1.33 WVoltageUo1.1 VCurrentIo11.9 mAPowerPo4 mWInternal capacitanceCi0 µFInternal inductanceLi0 mH: Ui. Voltage: < 28 V. Power: < 1.33 W. Voltage: 1.1 V. Current: 11.9 mA. Power: 4 mW. Internal capacitance: 0 µF. Internal inductance: 0 mH. Output I, II, III: terminals 7, 8, 9; 13, 14, 15; 19, 20, 21 non-intrinsically safe. Maximum safe voltageUm253 V (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 253 V (Attention! Um is no rated voltage.). Certificate: PF 07 CERT 1142 X. Marking II 3G Ex nA IIC T4 Gc: . Marking: II 3G Ex nA IIC T4 Gc. Galvanic isolation: . Input/Other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Other circuits: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. FM approval: . Control drawing116-0129: . Control drawing: 116-0129. IECEx approval: . IECEx certificateIECEx BAS 07.0047IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC: . IECEx certificate: IECEx BAS 07.0047. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Analog input |
Supply
| Connection | Power Rail or terminals 23+, 24- |
| Rated voltage | 19 ... 30 V DC Ur |
| Rated current | approx. 120 mA at 24 V DC Ir |
| Power dissipation | 2.3 W |
| Power consumption | 2.9 W |
HART signal channels (intrinsically safe)
| Conformity | HART field device input (revision 5 to 7) |
Interface
| Programming interface | programming socket |
Input
| Connection side | field side |
| Connection | terminals 1, 2, 3, 4, 5, 6 |
| Open circuit voltage/short-circuit current | typ. 24 V / 28 mA |
| Input resistance | 250 Ω , 5 % (terminals 2, 3 and with jumper on 5, 6) |
| Available voltage | ≥ 15.5 V at 20 mA, short-circuit protected |
Output
| Connection side | control side |
| Connection | output I: terminals 7, 8, 9 , output II: terminals 13, 14, 15 , output III: terminals 19, 20, 21 |
| Output signal | analog |
| Voltage range | 5 ... 30 V , sink mode from external supply |
| Current range | 4 ... 20 mA , (source or sink mode) |
| Load | max. 650 Ω , source mode |
| Fault signal | downscale I ≤ 2 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) or hold measurement value |
| Other outputs | HART communicator on terminals 22, 24 |
| Collective error message | Power Rail and LED red |
Transfer characteristics
| Output I, II, III | |
| Resolutionmax. 2 µAAccuracy< 20 µA, 10 µA typ.Influence of ambient temperature< ± 2 µA/KDuration of measurement/Response delayHART message acquisition time plus 100 ms | Resolution |
| Resolution | max. 2 µA |
| Accuracy | < 20 µA, 10 µA typ. |
| Influence of ambient temperature | < ± 2 µA/K |
| Duration of measurement/Response delay | HART message acquisition time plus 100 ms |
Galvanic isolation
| Output I/II/III/power supply | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
Indicators/settings
| Display elements | LEDs , display |
| Control elements | Control panel |
| Configuration | via operating buttons via PACTware |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Low voltage | |
| Directive 2014/35/EUEN 61010-1:2010 | Directive 2014/35/EU |
| Directive 2014/35/EU | EN 61010-1:2010 |
Conformity
| Electromagnetic compatibility | NE 21:2006 |
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | 300 g |
| Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | BASEEFA 07 ATEX 0174 |
| Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC | Marking |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC |
| Supply | |
| Maximum safe voltageUm253 V AC (Attention! The rated voltage can be lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 253 V AC (Attention! The rated voltage can be lower.) Um |
| Equipment | terminals 1, 4/3 (with link between terminals 4 and 5) |
| VoltageUo25.2 VCurrentIo104.9 mAPowerPo0.661 WInternal capacitanceCi1.1 nFInternal inductanceLi0 mH | Uo Voltage |
| Voltage | 25.2 V Uo |
| Current | 104.9 mA Io |
| Power | 0.661 W Po |
| Internal capacitance | 1.1 nF Ci |
| Internal inductance | 0 mH Li |
| Equipment | terminals 2, 5/3 |
| VoltageUi< 28 VPowerPi< 1.33 WVoltageUo1.1 VCurrentIo11.9 mAPowerPo4 mWInternal capacitanceCi0 µFInternal inductanceLi0 mH | Ui Voltage |
| Voltage | < 28 V Ui |
| Power | < 1.33 W Pi |
| Voltage | 1.1 V Uo |
| Current | 11.9 mA Io |
| Power | 4 mW Po |
| Internal capacitance | 0 µF Ci |
| Internal inductance | 0 mH Li |
| Output I, II, III | terminals 7, 8, 9; 13, 14, 15; 19, 20, 21 non-intrinsically safe |
| Maximum safe voltageUm253 V (Attention! Um is no rated voltage.) | Um Maximum safe voltage |
| Maximum safe voltage | 253 V (Attention! Um is no rated voltage.) Um |
| Certificate | PF 07 CERT 1142 X |
| Marking II 3G Ex nA IIC T4 Gc | Marking |
| Marking | II 3G Ex nA IIC T4 Gc |
| Galvanic isolation | |
| Input/Other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | Input/Other circuits |
| Input/Other circuits | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals
| FM approval | |
| Control drawing116-0129 | Control drawing |
| Control drawing | 116-0129 |
| IECEx approval | |
| IECEx certificateIECEx BAS 07.0047IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC | IECEx certificate |
| IECEx certificate | IECEx BAS 07.0047 |
| IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G