Pepperl Fuchs KFD2-EB2
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | K-System (DIN Rail Mounting, Highly Functional) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KFD2-EB2 be shipped?
KFD2-EB2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD2-EB2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD2-EB2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-EB2, subject to availability and destination.
Power Feed Module. Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication. Connection: terminals 11+, 12- terminals 8+, 9-. Rated voltage: 20 ... 30 V DC The maximum rated operating voltage of the devices plugged onto the Power Rail must not be exceeded.. Fusing: 5 AT/250 V AC recommended maximum utilization of the fuse: 80 %. Power dissipation: ≤ 1 W. Connection: Power Rail. Output current: max. 4 A. Output voltage: Ui ≥ rated voltage Ur = Ui - 0.6 V. Fault signal: relay output: NO contact. Contact loading: 30 V AC/ 2 A / cos φ ≥ 0.7 ; 40 V DC/ 2 A. Energized/De-energized delay: approx. 20 ms / approx. 20 ms. Display elements: LEDs. Control elements: DIP switch. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017. Degree of protection: IEC 60529:2001. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP20. Connection: screw terminals. Mass: approx. 100 g. Dimensions: 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. Certificate: UL 22 ATEX 2853 X. Marking II 3G Ex ec nC IIC T4 Gc: . Marking: II 3G Ex ec nC IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN IEC 60079-7:2015+A1:2018 , EN IEC 60079-15:2019: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN IEC 60079-7:2015+A1:2018 , EN IEC 60079-15:2019. FM approval: FM 22 US 0031 X. Control drawing116-0160: . Control drawing: 116-0160. UL approval: E106378. CSA approval: CoC 1051840. IECEx approval: . IECEx certificateIECEx UL 16.0051XIECEx markingEx ec nC IIC T4 Gc: . IECEx certificate: IECEx UL 16.0051X. IECEx marking: Ex ec nC IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
Supply
| Connection | terminals 11+, 12- terminals 8+, 9- |
| Rated voltage | 20 ... 30 V DC The maximum rated operating voltage of the devices plugged onto the Power Rail must not be exceeded. Ur |
| Fusing | 5 AT/250 V AC recommended maximum utilization of the fuse: 80 % |
| Power dissipation | ≤ 1 W |
Output
| Connection | Power Rail |
| Output current | max. 4 A |
| Output voltage | Ui ≥ rated voltage Ur = Ui - 0.6 V |
| Fault signal | relay output: NO contact |
| Contact loading | 30 V AC/ 2 A / cos φ ≥ 0.7 ; 40 V DC/ 2 A |
| Energized/De-energized delay | approx. 20 ms / approx. 20 ms |
Indicators/settings
| Display elements | LEDs |
| Control elements | DIP switch |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017 |
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 100 g |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| Certificate | UL 22 ATEX 2853 X |
| Marking II 3G Ex ec nC IIC T4 Gc | Marking |
| Marking | II 3G Ex ec nC IIC T4 Gc |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN IEC 60079-7:2015+A1:2018 , EN IEC 60079-15:2019 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN IEC 60079-7:2015+A1:2018 , EN IEC 60079-15:2019 |
International approvals
| FM approval | FM 22 US 0031 X |
| Control drawing116-0160 | Control drawing |
| Control drawing | 116-0160 |
| UL approval | E106378 |
| CSA approval | CoC 1051840 |
| IECEx approval | |
| IECEx certificateIECEx UL 16.0051XIECEx markingEx ec nC IIC T4 Gc | IECEx certificate |
| IECEx certificate | IECEx UL 16.0051X |
| IECEx marking | Ex ec nC IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G