Quick facts
| Availability | Confirmed on request |
| Category | Segment Coupler for PROFIBUS PA |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KFD2-BR-Ex1.3PA.93 be shipped?
KFD2-BR-Ex1.3PA.93 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD2-BR-Ex1.3PA.93 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD2-BR-Ex1.3PA.93 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-BR-Ex1.3PA.93, subject to availability and destination.
Gateway. Segment Coupler 1, intrinsically safe power supply and gateway for coupling PROFIBUS PA devices to PROFIBUS DP, Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator, IECEx approval, Dust protection, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk<BR>Zone 1 - intrinsically safe trunk. Installation in hazardous area: Zone 2 / Div. 2. Connection: Power Rail or terminals 59+, 60-, 58 FE. Rated voltage: 20 ... 35 V DC. Ripple: ≤ 10 %. Rated current: 190 mA ... 430 mA. Number of segments: 1. Rated voltage: 24 ... 26 V. PROFIBUS PA: . Connectionterminals 3, 18+; 2, 17-Rated voltage12.6 ... 13.4 VRated currentmax. 100 mATerminating impedance100 Ω , integrated: . Connection: terminals 3, 18+; 2, 17-. Rated voltage: 12.6 ... 13.4 V. Rated current: max. 100 mA. Terminating impedance: 100 Ω , integrated. PROFIBUS DP: PROFIBUS with RS-485 transmission technology. ConnectionTerminals 40 RxD/TxD-P, 41 RxD/TxD-N, 42 screen/FE, 55 DGND, 56 CNTR-P, 57 VPBaud rate93.75 kBit/sTerminating impedancewith rotary switch (S1) switchable: 1 = on; 0 = off: . Connection: Terminals 40 RxD/TxD-P, 41 RxD/TxD-N, 42 screen/FE, 55 DGND, 56 CNTR-P, 57 VP. Baud rate: 93.75 kBit/s. Terminating impedance: with rotary switch (S1) switchable: 1 = on; 0 = off. PROFIBUS DP/PROFIBUS PA: safe galvanic isolation acc. to EN 50020, voltage peak value 375 V. PROFIBUS DP/Supply: functional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff. PROFIBUS PA/Supply: safe galvanic isolation acc. to EN 50020, voltage peak value 375 V. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Galvanic isolation: EN 50178. Electromagnetic compatibility: NE 21:2006. Degree of protection: IEC 60529. Fieldbus standard: EN 50170/2. Climatic conditions: IEC 60721. Classification: 3K3. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: < 75 %. Pollution degree: max. 2, according to IEC 60664. Connection type: screw terminal , pluggable. Core cross section: up to 2.5 mm2. Housing: 100 mm x 115 mm x 107 mm. Housing material: Polycarbonate. Degree of protection: IP20. Mass: 650 g. Mounting: DIN rail mounting. EU-type examination certificate: PTB 99 ATEX 2142 , for additional certificates see www.pepperl-fuchs.com. Marking II (1) G [Ex ia] IIC Ga , [exsign] II (1) D [Ex ia] IIIC Da: . Marking: II (1) G [Ex ia] IIC Ga , [exsign] II (1) D [Ex ia] IIIC Da. Supply: . Maximum safe voltageUm253 V AC / 125 V DC (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 253 V AC / 125 V DC (Attention! Um is no rated voltage.). PROFIBUS PA: . VoltageUo15 VCurrentIo207.2 mAPowerPo1.93 WMaximum safe voltageUm60 V: Uo. Voltage: 15 V. Current: 207.2 mA. Power: 1.93 W. Maximum safe voltage: 60 V. Certificate: PF 15 CERT 3527 X. Marking II 3G Ex ec II T4 Gc: . Marking: II 3G Ex ec II T4 Gc. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012: . Directive 2014/34/EU: EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Installation in hazardous area | Zone 2 / Div. 2 |
Supply
| Connection | Power Rail or terminals 59+, 60-, 58 FE |
| Rated voltage | 20 ... 35 V DC Ur |
| Ripple | ≤ 10 % |
| Rated current | 190 mA ... 430 mA Ir |
Fieldbus connection
| Number of segments | 1 |
| Rated voltage | 24 ... 26 V UN |
| PROFIBUS PA | |
| Connectionterminals 3, 18+; 2, 17-Rated voltage12.6 ... 13.4 VRated currentmax. 100 mATerminating impedance100 Ω , integrated | Connection |
| Connection | terminals 3, 18+; 2, 17- |
| Rated voltage | 12.6 ... 13.4 V |
| Rated current | max. 100 mA |
| Terminating impedance | 100 Ω , integrated |
| PROFIBUS DP | PROFIBUS with RS-485 transmission technology |
| ConnectionTerminals 40 RxD/TxD-P, 41 RxD/TxD-N, 42 screen/FE, 55 DGND, 56 CNTR-P, 57 VPBaud rate93.75 kBit/sTerminating impedancewith rotary switch (S1) switchable: 1 = on; 0 = off | Connection |
| Connection | Terminals 40 RxD/TxD-P, 41 RxD/TxD-N, 42 screen/FE, 55 DGND, 56 CNTR-P, 57 VP |
| Baud rate | 93.75 kBit/s |
| Terminating impedance | with rotary switch (S1) switchable: 1 = on; 0 = off |
Galvanic isolation
| PROFIBUS DP/PROFIBUS PA | safe galvanic isolation acc. to EN 50020, voltage peak value 375 V |
| PROFIBUS DP/Supply | functional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff |
| PROFIBUS PA/Supply | safe galvanic isolation acc. to EN 50020, voltage peak value 375 V |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity
| Galvanic isolation | EN 50178 |
| Electromagnetic compatibility | NE 21:2006 |
| Degree of protection | IEC 60529 |
| Fieldbus standard | EN 50170/2 |
| Climatic conditions | IEC 60721 |
Ambient conditions
| Classification | 3K3 |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | < 75 % |
| Pollution degree | max. 2, according to IEC 60664 |
Mechanical specifications
| Connection type | screw terminal , pluggable |
| Core cross section | up to 2.5 mm2 |
| Housing | 100 mm x 115 mm x 107 mm |
| Housing material | Polycarbonate |
| Degree of protection | IP20 |
| Mass | 650 g |
| Mounting | DIN rail mounting |
Data for application in connection with hazardous areas
| EU-type examination certificate | PTB 99 ATEX 2142 , for additional certificates see www.pepperl-fuchs.com |
| Marking II (1) G [Ex ia] IIC Ga , [exsign] II (1) D [Ex ia] IIIC Da | Marking |
| Marking | II (1) G [Ex ia] IIC Ga , [exsign] II (1) D [Ex ia] IIIC Da |
| Supply | |
| Maximum safe voltageUm253 V AC / 125 V DC (Attention! Um is no rated voltage.) | Um Maximum safe voltage |
| Maximum safe voltage | 253 V AC / 125 V DC (Attention! Um is no rated voltage.) Um |
| PROFIBUS PA | |
| VoltageUo15 VCurrentIo207.2 mAPowerPo1.93 WMaximum safe voltageUm60 V | Uo Voltage |
| Voltage | 15 V Uo |
| Current | 207.2 mA Io |
| Power | 1.93 W Po |
| Maximum safe voltage | 60 V Um |
| Certificate | PF 15 CERT 3527 X |
| Marking II 3G Ex ec II T4 Gc | Marking |
| Marking | II 3G Ex ec II T4 Gc |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 |