Quick facts
| Availability | Confirmed on request |
| Category | Segment Coupler for PROFIBUS PA |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KFD2-BR-1.PA.1500 be shipped?
KFD2-BR-1.PA.1500 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD2-BR-1.PA.1500 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD2-BR-1.PA.1500 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-BR-1.PA.1500, subject to availability and destination.
Segment Coupler. Segment coupler 1, power supply and gateway for PROFIBUS DP to PROFIBUS PA communication, Output: 24 ... 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting, Europe, USA, Canada. Installation in hazardous area: Zone 2 / Div. 2. Connection: Power Rail or terminals 11 (L+), 12 (L-). Rated voltage: 20 ... 30 V DC. Ripple: ≤ 10 %. Rated current: 640 mA ... 365 mA. Power dissipation: max 2.5 W. Number of segments: 1. Rated voltage: 12.6 ... 13.4 V. PROFIBUS PA: . Connection3+, 6+, 2-, 5-, 1 shield, 4 shieldRated voltage24 ... 26 VRated currentmax. 400 mATerminating impedance100 Ω , integrated: . Connection: 3+, 6+, 2-, 5-, 1 shield, 4 shield. Rated voltage: 24 ... 26 V. Rated current: max. 400 mA. Terminating impedance: 100 Ω , integrated. PROFIBUS DP: PROFIBUS with RS-485 transmission technology. Connectionterminals 7 RxD/TxD-P, 8 RxD/TxD-N, 9 shield, 10 FEBaud rate1.5 MBit/s max.: . Connection: terminals 7 RxD/TxD-P, 8 RxD/TxD-N, 9 shield, 10 FE. Baud rate: 1.5 MBit/s max.. Switch: PROFIBUS DP terminator. LED PWR: green: Power on. LED DP/ERR: red 2 Hz flashing: DP error red on: Hardware error red off: DP communication detected. LED PA: red 2 Hz flashing: No PA communication or overload Off: PA communication OK. PROFIBUS DP/PROFIBUS PA: functional insulation acc. to IEC 62103, rated insulation voltage 50 V AC /70 V DC. PROFIBUS DP/Supply: basic insulation according to IEC/EN 61010, rated insulation voltage 253 V AC /357 V DC. PROFIBUS PA/Supply: basic insulation according to IEC/EN 61010, rated insulation voltage 253 V AC /357 V DC. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NAMUR NE 21. Degree of protection: IEC/EN 60529. Fieldbus standard: EN 50170/2. Climatic conditions: DIN IEC 721. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: < 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g 10 ... 150 Hz. Pollution degree: max. 2, according to IEC 60664. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Connection type: screw terminal , pluggable. Core cross section: up to 2.5 mm2. Housing material: Polycarbonate. Degree of protection: IP20. Mass: 180 g. Mounting: DIN rail mounting. Certificate: TÜV 16 ATEX 7831 X. Marking II 3G Ex ec IIC T4 Gc: . Marking: II 3G Ex ec IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018. CSA approval: CSA 16.70064204. Approved forClass I, Division 2, Groups A, B, C, DClass I, Zone 2, Ex nA IIC T4 Gc: . Approved for: Class I, Division 2, Groups A, B, C, DClass I, Zone 2, Ex nA IIC T4 Gc. IECEx approval: IECEx TUR 16.0006X. Approved forEx ec IIC T4 Gc: . Approved for: Ex ec IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Installation in hazardous area | Zone 2 / Div. 2 |
Supply
| Connection | Power Rail or terminals 11 (L+), 12 (L-) |
| Rated voltage | 20 ... 30 V DC Ur |
| Ripple | ≤ 10 % |
| Rated current | 640 mA ... 365 mA Ir |
| Power dissipation | max 2.5 W |
Fieldbus connection
| Number of segments | 1 |
| Rated voltage | 12.6 ... 13.4 V UN |
| PROFIBUS PA | |
| Connection3+, 6+, 2-, 5-, 1 shield, 4 shieldRated voltage24 ... 26 VRated currentmax. 400 mATerminating impedance100 Ω , integrated | Connection |
| Connection | 3+, 6+, 2-, 5-, 1 shield, 4 shield |
| Rated voltage | 24 ... 26 V |
| Rated current | max. 400 mA |
| Terminating impedance | 100 Ω , integrated |
| PROFIBUS DP | PROFIBUS with RS-485 transmission technology |
| Connectionterminals 7 RxD/TxD-P, 8 RxD/TxD-N, 9 shield, 10 FEBaud rate1.5 MBit/s max. | Connection |
| Connection | terminals 7 RxD/TxD-P, 8 RxD/TxD-N, 9 shield, 10 FE |
| Baud rate | 1.5 MBit/s max. |
Indicators/operating means
| Switch | PROFIBUS DP terminator |
| LED PWR | green: Power on |
| LED DP/ERR | red 2 Hz flashing: DP error red on: Hardware error red off: DP communication detected |
| LED PA | red 2 Hz flashing: No PA communication or overload Off: PA communication OK |
Galvanic isolation
| PROFIBUS DP/PROFIBUS PA | functional insulation acc. to IEC 62103, rated insulation voltage 50 V AC /70 V DC |
| PROFIBUS DP/Supply | basic insulation according to IEC/EN 61010, rated insulation voltage 253 V AC /357 V DC |
| PROFIBUS PA/Supply | basic insulation according to IEC/EN 61010, rated insulation voltage 253 V AC /357 V DC |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity
| Electromagnetic compatibility | NAMUR NE 21 |
| Degree of protection | IEC/EN 60529 |
| Fieldbus standard | EN 50170/2 |
| Climatic conditions | DIN IEC 721 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | < 95 % non-condensing |
| Shock resistance | 15 g 11 ms |
| Vibration resistance | 1 g 10 ... 150 Hz |
| Pollution degree | max. 2, according to IEC 60664 |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Connection type | screw terminal , pluggable |
| Core cross section | up to 2.5 mm2 |
| Housing material | Polycarbonate |
| Degree of protection | IP20 |
| Mass | 180 g |
| Mounting | DIN rail mounting |
Data for application in connection with hazardous areas
| Certificate | TÜV 16 ATEX 7831 X |
| Marking II 3G Ex ec IIC T4 Gc | Marking |
| Marking | II 3G Ex ec IIC T4 Gc |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 |
International approvals
| CSA approval | CSA 16.70064204 |
| Approved forClass I, Division 2, Groups A, B, C, DClass I, Zone 2, Ex nA IIC T4 Gc | Approved for |
| Approved for | Class I, Division 2, Groups A, B, C, DClass I, Zone 2, Ex nA IIC T4 Gc |
| IECEx approval | IECEx TUR 16.0006X |
| Approved forEx ec IIC T4 Gc | Approved for |
| Approved for | Ex ec IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G