Pepperl Fuchs KFD0-TT-Ex1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | K-System (DIN Rail Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KFD0-TT-Ex1 be shipped?
KFD0-TT-Ex1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD0-TT-Ex1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD0-TT-Ex1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD0-TT-Ex1, subject to availability and destination.
Thermocouple Converter. 1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Housing width: 20 mm, Number of channels: 1-channel, Internal cold junction compensation, Rated voltage: 12 ... 35 V DC loop powered, Type: 2-wire connection, Field device: Thermocouple, Line fault detection, Signal: 1 x 4 ... 20 mA (current sink). Signal type: Analog input. Rated voltage: 12 ... 35 V DC loop powered. Power dissipation: 0.4 W. Connection side: field side. Connection: terminals 1+, 2-, 3- thermocouple E, J, K, N, R, S or T, cold junction referenced to 0 °C (32 °F). Lead resistance: max. 100 Ω per line. Current: lead monitoring ON: ≤ 15 nA; OFF: ≤ 1 nA. Connection side: control side. Connection: terminals 9+, 8-. Load: (U -12 V) / 0.02 A. Current output: 4 ... 20 mA , limited to ≤ 35 mA. Fault signal: downscaling ≤ 3 mA , upscaling ≥ 22 mA. Measuring range: span 4 ... 100 mV, zero point -12 ... 60 mV , both adjustable. Deviation: . After calibration0.1 % of full-scale value ± 1 K for the cold junctionTemperature effect temperature deviation 0.015 % of the span/K or 1.5 µV/K cold junction ± 2 K (calibrated at Tamb = 20 °C (68 °F))Influence of supply voltage6.5 ppm/V: . After calibration: 0.1 % of full-scale value ± 1 K for the cold junction. Temperature effect: temperature deviation 0.015 % of the span/K or 1.5 µV/K cold junction ± 2 K (calibrated at Tamb = 20 °C (68 °F)). Influence of supply voltage: 6.5 ppm/V. Characteristic curve: the output voltage is linearly proportionate to the input voltage (not to temperature). Rise time: 250 ms. Input/Output: safe isolation according to EN 50178, rated insulation voltage 253 Veff. Control elements: DIP switch rotary switch. Configuration: via DIP switches via rotary switch. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Insulation coordination: EN 50178. Galvanic isolation: EN 50178. Degree of protection: IEC 60529. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Degree of protection: IP20. Connection: screw terminals. Mass: approx. 150 g. Dimensions: 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2. Height119 mmWidth20 mmDepth115 mm: . Height: 119 mm. Width: 20 mm. Depth: 115 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: ZELM 00 ATEX 0035. Marking II (1)GD [EEx ia] IICVoltageUo16.1 VCurrentIo0.8 mAPowerPo3.2 mW: . Marking: II (1)GD [EEx ia] IIC. Voltage: 16.1 V. Current: 0.8 mA. Power: 3.2 mW. Output: . Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 60 V (Attention! The rated voltage can be lower.). Certificate: TÜV 01 ATEX 1777 X. Marking II 3G Ex nA II T4: . Marking: II 3G Ex nA II T4. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010. CSA approval: . Control drawing116-0132: . Control drawing: 116-0132. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Analog input |
Supply
| Rated voltage | 12 ... 35 V DC loop powered Ur |
| Power dissipation | 0.4 W |
Input
| Connection side | field side |
| Connection | terminals 1+, 2-, 3- thermocouple E, J, K, N, R, S or T, cold junction referenced to 0 °C (32 °F) |
| Lead resistance | max. 100 Ω per line |
| Current | lead monitoring ON: ≤ 15 nA; OFF: ≤ 1 nA |
Output
| Connection side | control side |
| Connection | terminals 9+, 8- |
| Load | (U -12 V) / 0.02 A |
| Current output | 4 ... 20 mA , limited to ≤ 35 mA |
| Fault signal | downscaling ≤ 3 mA , upscaling ≥ 22 mA |
Transfer characteristics
| Measuring range | span 4 ... 100 mV, zero point -12 ... 60 mV , both adjustable fn |
| Deviation | |
| After calibration0.1 % of full-scale value ± 1 K for the cold junctionTemperature effect temperature deviation 0.015 % of the span/K or 1.5 µV/K cold junction ± 2 K (calibrated at Tamb = 20 °C (68 °F))Influence of supply voltage6.5 ppm/V | After calibration |
| After calibration | 0.1 % of full-scale value ± 1 K for the cold junction |
| Temperature effect | temperature deviation 0.015 % of the span/K or 1.5 µV/K cold junction ± 2 K (calibrated at Tamb = 20 °C (68 °F)) |
| Influence of supply voltage | 6.5 ppm/V |
| Characteristic curve | the output voltage is linearly proportionate to the input voltage (not to temperature) |
| Rise time | 250 ms |
Galvanic isolation
| Input/Output | safe isolation according to EN 50178, rated insulation voltage 253 Veff |
Indicators/settings
| Control elements | DIP switch rotary switch |
| Configuration | via DIP switches via rotary switch |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Insulation coordination | EN 50178 |
| Galvanic isolation | EN 50178 |
| Degree of protection | IEC 60529 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 150 g |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Height119 mmWidth20 mmDepth115 mm | Height |
| Height | 119 mm |
| Width | 20 mm |
| Depth | 115 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | ZELM 00 ATEX 0035 |
| Marking II (1)GD [EEx ia] IICVoltageUo16.1 VCurrentIo0.8 mAPowerPo3.2 mW | Marking |
| Marking | II (1)GD [EEx ia] IIC |
| Voltage | 16.1 V Uo |
| Current | 0.8 mA Io |
| Power | 3.2 mW Po |
| Output | |
| Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 60 V (Attention! The rated voltage can be lower.) Um |
| Certificate | TÜV 01 ATEX 1777 X |
| Marking II 3G Ex nA II T4 | Marking |
| Marking | II 3G Ex nA II T4 |
| Galvanic isolation | |
| Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | Input/Output |
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals
| CSA approval | |
| Control drawing116-0132 | Control drawing |
| Control drawing | 116-0132 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G