Pepperl Fuchs KFD0-HMS-16
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | K-System |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KFD0-HMS-16 be shipped?
KFD0-HMS-16 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD0-HMS-16 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD0-HMS-16 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD0-HMS-16, subject to availability and destination.
HART MUX Secondary Module. 16-channel, No external power required, HART field device input (revision 5 to 7), Used with HART MUX primary module KFD2-HMM-16, Up to SIL 3 acc. to IEC/EN 61508. Safety Integrity Level (SIL): SIL 3. Connection: via 14-channel flat cable from the KFD2-HMM-16 primary module. Conformity: HART field device input (revision 5 to 7). Connection: 26-pin flat cable for analog connections 14-pin flat cable for primary module/secondary module connection between KFD2-HMM-16 and KFD0-HMS-16. Leakage current: < 3 µA at -20 ... 85 °C (-4 ... 185 °F). Terminating resistor: external 230 ... 500 Ω standard (up to 1000 Ω possible). Output voltage: ≥ 400 mV ss (with the terminator resistance specified above). Output resistance: 100 Ω or smaller, capacitive coupling. Input impedance: according to HART specification. Input voltage range: 0.08 ... 4 V ss ; typ. ± 5.2 V as local reference. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Degree of protection: IEC 60529:2001. Ambient temperature: -20 ... 65 °C (-4 ... 149 °F). Degree of protection: IP20. Mass: approx. 100 g. Dimensions: 20 x 93 x 115 mm (0.8 x 3.7 x 4.5 inch) (W x H x D) , housing type B1. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. Certificate: PF 07 CERT 1143 X. Marking II 3G Ex nA IIC T4 Gc: . Marking: II 3G Ex nA IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-15:2010. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
Supply
| Connection | via 14-channel flat cable from the KFD2-HMM-16 primary module |
HART signal channels (non-intrinsically safe)
| Conformity | HART field device input (revision 5 to 7) |
| Connection | 26-pin flat cable for analog connections 14-pin flat cable for primary module/secondary module connection between KFD2-HMM-16 and KFD0-HMS-16 |
| Leakage current | < 3 µA at -20 ... 85 °C (-4 ... 185 °F) |
| Terminating resistor | external 230 ... 500 Ω standard (up to 1000 Ω possible) |
| Output voltage | ≥ 400 mV ss (with the terminator resistance specified above) |
| Output resistance | 100 Ω or smaller, capacitive coupling |
| Input impedance | according to HART specification |
| Input voltage range | 0.08 ... 4 V ss ; typ. ± 5.2 V as local reference |
Indicators/settings
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Mass | approx. 100 g |
| Dimensions | 20 x 93 x 115 mm (0.8 x 3.7 x 4.5 inch) (W x H x D) , housing type B1 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| Certificate | PF 07 CERT 1143 X |
| Marking II 3G Ex nA IIC T4 Gc | |
| Marking | II 3G Ex nA IIC T4 Gc |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G