| Availability | Confirmed on request |
| Category | K-System (DIN Rail Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KFD0-CS-Ex2.54 be shipped?
KFD0-CS-Ex2.54 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD0-CS-Ex2.54 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD0-CS-Ex2.54 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD0-CS-Ex2.54, subject to availability and destination.
Repeater. 2-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the control system, HART communication, Safety Integrity Level (SIL): SIL 3, Rated voltage: 0 ... 24 V DC , loop powered, Signal: 2 x 1 ... 20 mA, Signal [2]: 2 x HART, Device: 2 x fire alarm, Signal: 2 x 1 ... 20 mA. Signal type: Analog input. Safety Integrity Level (SIL): SIL 3. Rated voltage: 0 ... 24 V DC , loop powered. Power dissipation: < 0.2 W for Uin = 24 V, Iout = 20 mA. Connection: terminals 11+, 12-; 9+, 10-, 8-. Voltage: 0 ... 24 V. Current: 0 ... 20 mA. Current limit: max. 35 mA , limited by control sided current source. Connection: terminals 1+, 2-; 4+, 5-. Voltage: for 4 V ≤ Uin ≤ 24 V: Uout ≥ Uin - (0.41 x Iin in mA) - 0.5. Transmission range: voltage: 4 ... 20 V DC/0 ... 6 Vpp AC current: 1 ... 20 mA. Deviation: . After calibration≤ 3.5 mA current loss at 20 mA load currentInfluence of ambient temperature± 20 µA / K: . After calibration: ≤ 3.5 mA current loss at 20 mA load current. Influence of ambient temperature: ± 20 µA / K. Rise time/fall time: ≤ 50 µs (load current ≥ 1 mA). Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2006. Degree of protection: IEC 60529:2001. Protection against electrical shock: UL 61010-1. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Degree of protection: IP20. Connection: screw terminals. Mass: approx. 100 g. Dimensions: 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) (W x H x D) , housing type B1. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: BAS 00 ATEX 7087. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IVoltageUo28 VCurrentIo93 mAPowerPo653 mW: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Voltage: 28 V. Current: 93 mA. Power: 653 mW. Supply: . Maximum safe voltageUm253 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 253 V (Attention! The rated voltage can be lower.). Certificate: TÜV 99 ATEX 1499 X. Marking II 3G Ex nA II T4: . Marking: II 3G Ex nA II T4. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. FM approval: . Control drawing116-0129 (cFMus): . Control drawing: 116-0129 (cFMus). IECEx approval: . IECEx certificateIECEx BAS 08.0079 IECEx BAS 10.0007XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex nA IIC T4 Gc: . IECEx certificate: IECEx BAS 08.0079 IECEx BAS 10.0007X. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex nA IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Analog input |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
Supply
| Rated voltage | 0 ... 24 V DC , loop powered Ur |
| Power dissipation | < 0.2 W for Uin = 24 V, Iout = 20 mA |
Control circuit
| Connection | terminals 11+, 12-; 9+, 10-, 8- |
| Voltage | 0 ... 24 V |
| Current | 0 ... 20 mA |
| Current limit | max. 35 mA , limited by control sided current source |
Field circuit
| Connection | terminals 1+, 2-; 4+, 5- |
| Voltage | for 4 V ≤ Uin ≤ 24 V: Uout ≥ Uin - (0.41 x Iin in mA) - 0.5 |
| Transmission range | voltage: 4 ... 20 V DC/0 ... 6 Vpp AC current: 1 ... 20 mA |
Transfer characteristics
| Deviation | |
| After calibration≤ 3.5 mA current loss at 20 mA load currentInfluence of ambient temperature± 20 µA / K | After calibration |
| After calibration | ≤ 3.5 mA current loss at 20 mA load current |
| Influence of ambient temperature | ± 20 µA / K |
| Rise time/fall time | ≤ 50 µs (load current ≥ 1 mA) |
Galvanic isolation
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
Indicators/settings
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2006 |
| Degree of protection | IEC 60529:2001 |
| Protection against electrical shock | UL 61010-1 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 100 g |
| Dimensions | 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) (W x H x D) , housing type B1 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | BAS 00 ATEX 7087 |
| Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IVoltageUo28 VCurrentIo93 mAPowerPo653 mW | Marking |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Voltage | 28 V Uo |
| Current | 93 mA Io |
| Power | 653 mW Po |
| Supply | |
| Maximum safe voltageUm253 V (Attention! The rated voltage can be lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 253 V (Attention! The rated voltage can be lower.) Um |
| Certificate | TÜV 99 ATEX 1499 X |
| Marking II 3G Ex nA II T4 | Marking |
| Marking | II 3G Ex nA II T4 |
| Galvanic isolation | |
| Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | Input/Output |
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals
| FM approval | |
| Control drawing116-0129 (cFMus) | Control drawing |
| Control drawing | 116-0129 (cFMus) |
| IECEx approval | |
| IECEx certificateIECEx BAS 08.0079 IECEx BAS 10.0007XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex nA IIC T4 Gc | IECEx certificate |
| IECEx certificate | IECEx BAS 08.0079 IECEx BAS 10.0007X |
| IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex nA IIC T4 Gc |