Pepperl Fuchs KCD2-VR4-Ex1.SP
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | K-System (DIN Rail Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KCD2-VR4-Ex1.SP be shipped?
KCD2-VR4-Ex1.SP is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KCD2-VR4-Ex1.SP in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KCD2-VR4-Ex1.SP and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-VR4-Ex1.SP, subject to availability and destination.
Voltage Repeater. 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -20 V ... 0 V, extended -20 V ... +5 V, Vibration sensor inputs, Voltage/current field supply, Voltage output -20 V ... 0 V, extended -20 V ... +5 V, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2. Signal type: Analog input. Safety Integrity Level (SIL): SIL 2. Systematic capability (SC): SC 3. Connection: Power Rail or terminals 9+, 10-. Rated voltage: 19 ... 30 V DC. Ripple: within the supply tolerance. Power dissipation: ≤ 0.9 W. Power consumption: ≤ 1.2 W. Connection side: field side. Connection: terminals 2 (common), 3 (sensor supply -), 1 and 4 (signal -). Sensor supply: sensor supply depending on DIP switches configuration and external jumper: voltage: -18 V at 20 mA (short circuit limited at approx. 23 mA) current: 3.6 mA or 5.3 mA or 8.9 mA (±10 %) at -10 V reduced sensor supply option (-2.5 V compared to standard setting). Input resistance: 10 kΩ terminals 2 (common), 1 and 4. Transmission range: -20 ... 0 V extended voltage range : -20 ... 5 V. Connection side: control side. Connection: terminals 5+, 6- (monitoring) limited electrical values: max. 30V, max. 5A. Voltage: -20 ... 0 V extended voltage range : -20 ... 5 V. Load: ≥ 9 kΩ (3-wire sensor), ≥ 2 kΩ (2-wire sensor). Output resistance: max. 5 Ω. Cut-off frequency: 20 kHz (-1 dB). Deviation: at 20 °C transfer error (with 10 kΩ load) < 20 mV, provided that the alternating component of the input voltage is not excessive, e. g. - square waves (0 ... 20 kHz): 5 Vpp - sine waves (0 ... 20 kHz): the full span of 20 Vpp (= 100 g peak acceleration at 100 mV/g) is acceptable.. Influence of ambient temperature(< 100 ppm of span)/K at any point within the span: . Influence of ambient temperature: (< 100 ppm of span)/K at any point within the span. Time delay relative to input: 5 µs. Ripple: in 200 kHz bandwidth < 20 mVrmsin 20 kHz bandwidth < 3 mVrms. Input/Output: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Input/power supply: basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Output/power supply: basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Display elements: LEDs. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017 EN IEC 61326-3-2:2018. Degree of protection: IEC 60529:2013. Protection against electrical shock: UL 61010-1:2023. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP20. Connection: spring terminals. Mass: approx. 100 g. Dimensions: 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: UL 24 ATEX 3300 X. Marking II 3(1)G Ex ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IInputEx ia Ga, Ex ia Da Refer to certificate for alternative parameters.: . Marking: II 3(1)G Ex ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Input: Ex ia Ga, Ex ia Da Refer to certificate for alternative parameters.. Supply: . Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.). Equipment: . Connectionterminals 1, 2VoltageUi30 VVoltageUo1.1 VCurrentIo0.12 mAPowerPo0.031 mW: . Connection: terminals 1, 2. Voltage: 30 V. Voltage: 1.1 V. Current: 0.12 mA. Power: 0.031 mW. Equipment: . Connectionterminals 1 ... 4VoltageUo26.3 VCurrentIo32.4 mAPowerPo596 mW (angular characteristic curve): . Connection: terminals 1 ... 4. Voltage: 26.3 V. Current: 32.4 mA. Power: 596 mW (angular characteristic curve). Output: . Maximum safe voltageUm250 V (Attention! The rated voltage is lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage is lower.). Galvanic isolation: . Input/Outputsafe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 VInput/power supplysafe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V: . Input/Output: safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V. Input/power supply: safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , IEC 60079-11:2023 , EN IEC 60079-7:2015+A1:2018: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , IEC 60079-11:2023 , EN IEC 60079-7:2015+A1:2018. IECEx approval: . IECEx certificateIECEx ULD 24.0028XIECEx markingEx ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx ULD 24.0028X. IECEx marking: Ex ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Analog input |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| Systematic capability (SC) | SC 3 |
Supply
| Connection | Power Rail or terminals 9+, 10- |
| Rated voltage | 19 ... 30 V DC Ur |
| Ripple | within the supply tolerance |
| Power dissipation | ≤ 0.9 W |
| Power consumption | ≤ 1.2 W |
Input
| Connection side | field side |
| Connection | terminals 2 (common), 3 (sensor supply -), 1 and 4 (signal -) |
| Sensor supply | sensor supply depending on DIP switches configuration and external jumper: voltage: -18 V at 20 mA (short circuit limited at approx. 23 mA) current: 3.6 mA or 5.3 mA or 8.9 mA (±10 %) at -10 V reduced sensor supply option (-2.5 V compared to standard setting) |
| Input resistance | 10 kΩ terminals 2 (common), 1 and 4 |
| Transmission range | -20 ... 0 V extended voltage range : -20 ... 5 V |
Output
| Connection side | control side |
| Connection | terminals 5+, 6- (monitoring) limited electrical values: max. 30V, max. 5A |
| Voltage | -20 ... 0 V extended voltage range : -20 ... 5 V |
| Load | ≥ 9 kΩ (3-wire sensor), ≥ 2 kΩ (2-wire sensor) |
| Output resistance | max. 5 Ω |
Transfer characteristics
| Cut-off frequency | 20 kHz (-1 dB) |
| Deviation | at 20 °C transfer error (with 10 kΩ load) < 20 mV, provided that the alternating component of the input voltage is not excessive, e. g. - square waves (0 ... 20 kHz): 5 Vpp - sine waves (0 ... 20 kHz): the full span of 20 Vpp (= 100 g peak acceleration at 100 mV/g) is acceptable. |
| Influence of ambient temperature(< 100 ppm of span)/K at any point within the span | Influence of ambient temperature |
| Influence of ambient temperature | (< 100 ppm of span)/K at any point within the span |
| Time delay relative to input | 5 µs |
| Ripple | in 200 kHz bandwidth < 20 mVrmsin 20 kHz bandwidth < 3 mVrms |
Galvanic isolation
| Input/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Input/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LEDs |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017 EN IEC 61326-3-2:2018 |
| Degree of protection | IEC 60529:2013 |
| Protection against electrical shock | UL 61010-1:2023 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | spring terminals |
| Mass | approx. 100 g |
| Dimensions | 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | UL 24 ATEX 3300 X |
| Marking II 3(1)G Ex ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IInputEx ia Ga, Ex ia Da Refer to certificate for alternative parameters. | Marking |
| Marking | II 3(1)G Ex ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Input | Ex ia Ga, Ex ia Da Refer to certificate for alternative parameters. |
| Supply | |
| Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) Um |
| Equipment | |
| Connectionterminals 1, 2VoltageUi30 VVoltageUo1.1 VCurrentIo0.12 mAPowerPo0.031 mW | Connection |
| Connection | terminals 1, 2 |
| Voltage | 30 V Ui |
| Voltage | 1.1 V Uo |
| Current | 0.12 mA Io |
| Power | 0.031 mW Po |
| Equipment | |
| Connectionterminals 1 ... 4VoltageUo26.3 VCurrentIo32.4 mAPowerPo596 mW (angular characteristic curve) | Connection |
| Connection | terminals 1 ... 4 |
| Voltage | 26.3 V Uo |
| Current | 32.4 mA Io |
| Power | 596 mW (angular characteristic curve) Po |
| Output | |
| Maximum safe voltageUm250 V (Attention! The rated voltage is lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 250 V (Attention! The rated voltage is lower.) Um |
| Galvanic isolation | |
| Input/Outputsafe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 VInput/power supplysafe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V | Input/Output |
| Input/Output | safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V |
| Input/power supply | safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , IEC 60079-11:2023 , EN IEC 60079-7:2015+A1:2018 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , IEC 60079-11:2023 , EN IEC 60079-7:2015+A1:2018 |
International approvals
| IECEx approval | |
| IECEx certificateIECEx ULD 24.0028XIECEx markingEx ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I | IECEx certificate |
| IECEx certificate | IECEx ULD 24.0028X |
| IECEx marking | Ex ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G