Available on request

Pepperl Fuchs KCD2-SLD-Ex1.1045

MPN: KCD2-SLD-Ex1.1045 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryK-System (DIN Rail Mounting)
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can KCD2-SLD-Ex1.1045 be shipped?

KCD2-SLD-Ex1.1045 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KCD2-SLD-Ex1.1045 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KCD2-SLD-Ex1.1045 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-SLD-Ex1.1045, subject to availability and destination.

Solenoid Driver. 1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC <BR>loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 1 x Valve. Signal type: Digital Output. Safety Integrity Level (SIL): SIL 3. Systematic capability (SC): SC 3. Connection: terminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered. Rated voltage: 19 ... 30 V DC loop powered. Input current: 75 mA at 24 V, 220 Ω load. Power dissipation: 1.4 W at 24 V, 220 Ω load. Connection side: control side. Connection: terminals 5+, 6-. Test pulse length: max. 2 ms from DO card. Signal level: loop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited to 5 mA)0-signal: 0 ... 5 V DC. Rated current: 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card). Inrush current: < 200 mA , 10 ms loop powered. Connection side: field side. Connection: terminals 1+, 2-. Internal resistor: 285 Ω. Current: typ. 45 mA. Voltage: typ. 10 V. Current limit: 45 mA. Open loop voltage: typ. 24.6 V. Load: nominal 0.05 ... 18 kΩ , valid range for line fault detection (LFD). Output II: fault signal. Connectionterminals 7, 8 , non-intrinsically safeContact loading30 V DC/ 0.5 A resistive loadMechanical life105 switching cyclesEnergized/De-energized delay≤ 20 ms / ≤ 20 ms: . Connection: terminals 7, 8 , non-intrinsically safe. Contact loading: 30 V DC/ 0.5 A resistive load. Mechanical life: 105 switching cycles. Energized/De-energized delay: ≤ 20 ms / ≤ 20 ms. Line fault detection: . Test currentmax. 350 µA , calculated by ILFD = 4.7 V / (15 kΩ + RLoad): . Test current: max. 350 µA , calculated by ILFD = 4.7 V / (15 kΩ + RLoad). Output/other circuits: basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Output II/power supply: basic insulation according to IEC/EN 61010-1, rated insulation voltage 32 Veff. Display elements: LEDs. Control elements: DIP switch. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2012 , EN 61326-3-2:2008 For further information see system description.. Degree of protection: IEC 60529:2013. Protection against electrical shock: EN 61010-1:2010. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating.. Degree of protection: IP20. Connection: screw terminals. Mass: approx. 150 g. Dimensions: 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: EXA 17 ATEX 0002 X. Marking II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IOutput IEx iaVoltageUo26 VCurrentIo93 mAPowerPo605 mW: . Marking: II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Output I: Ex ia. Voltage: 26 V. Current: 93 mA. Power: 605 mW. Supply: . Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 60 V (Attention! The rated voltage can be lower.). Input: . Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 60 V (Attention! The rated voltage can be lower.). Collective error message: . Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 60 V (Attention! The rated voltage can be lower.). Galvanic isolation: . Output I/other circuitssafe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms: . Output I/other circuits: safe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010. UL approval: E106378. Control drawing116-0448 (cULus): . Control drawing: 116-0448 (cULus). IECEx approval: . IECEx certificateIECEx EXA 17.0001XIECEx markingEx nC ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx EXA 17.0001X. IECEx marking: Ex nC ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Signal typeDigital Output

Functional safety related parameters

Safety Integrity Level (SIL)SIL 3
Systematic capability (SC)SC 3

Supply

Connectionterminals 5+, 6- loop powered Power Rail or terminals 9+, 10- bus powered
Rated voltage19 ... 30 V DC loop powered Ur
Input current75 mA at 24 V, 220 Ω load
Power dissipation1.4 W at 24 V, 220 Ω load

Input

Connection sidecontrol side
Connectionterminals 5+, 6-
Test pulse lengthmax. 2 ms from DO card
Signal levelloop powered 1-signal: 19 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited to 5 mA)0-signal: 0 ... 5 V DC
Rated current0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card) Ir
Inrush current< 200 mA , 10 ms loop powered

Output

Connection sidefield side
Connectionterminals 1+, 2-
Internal resistor285 Ω Ri
Currenttyp. 45 mA Ie
Voltagetyp. 10 V Ue
Current limit45 mA Imax
Open loop voltagetyp. 24.6 V Us
Loadnominal 0.05 ... 18 kΩ , valid range for line fault detection (LFD)
Output IIfault signal
Connectionterminals 7, 8 , non-intrinsically safeContact loading30 V DC/ 0.5 A resistive loadMechanical life105 switching cyclesEnergized/De-energized delay≤ 20 ms / ≤ 20 ms Connection
Connectionterminals 7, 8 , non-intrinsically safe
Contact loading30 V DC/ 0.5 A resistive load
Mechanical life105 switching cycles
Energized/De-energized delay≤ 20 ms / ≤ 20 ms
Line fault detection
Test currentmax. 350 µA , calculated by ILFD = 4.7 V / (15 kΩ + RLoad) Test current
Test currentmax. 350 µA , calculated by ILFD = 4.7 V / (15 kΩ + RLoad)

Galvanic isolation

Output/other circuitsbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output II/power supplybasic insulation according to IEC/EN 61010-1, rated insulation voltage 32 Veff

Indicators/settings

Display elementsLEDs
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations) Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2012 , EN 61326-3-2:2008 For further information see system description.
Degree of protectionIEC 60529:2013
Protection against electrical shockEN 61010-1:2010

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating.

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 150 g
Dimensions12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateEXA 17 ATEX 0002 X
Marking II 3(1)G Ex nC ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IOutput IEx iaVoltageUo26 VCurrentIo93 mAPowerPo605 mW Marking
MarkingII 3(1)G Ex nC ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Output IEx ia
Voltage26 V Uo
Current93 mA Io
Power605 mW Po
Supply
Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.)Um Maximum safe voltage
Maximum safe voltage60 V (Attention! The rated voltage can be lower.) Um
Input
Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.)Um Maximum safe voltage
Maximum safe voltage60 V (Attention! The rated voltage can be lower.) Um
Collective error message
Maximum safe voltageUm60 V (Attention! The rated voltage can be lower.)Um Maximum safe voltage
Maximum safe voltage60 V (Attention! The rated voltage can be lower.) Um
Galvanic isolation
Output I/other circuitssafe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms Output I/other circuits
Output I/other circuitssafe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010 Directive 2014/34/EU
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-15:2010

International approvals

UL approvalE106378
Control drawing116-0448 (cULus) Control drawing
Control drawing116-0448 (cULus)
IECEx approval
IECEx certificateIECEx EXA 17.0001XIECEx markingEx nC ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I IECEx certificate
IECEx certificateIECEx EXA 17.0001X
IECEx markingEx nC ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request