Pepperl Fuchs KCD2-SCS-2
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | K-System (DIN Rail Mounting, Highly Functional) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KCD2-SCS-2 be shipped?
KCD2-SCS-2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KCD2-SCS-2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KCD2-SCS-2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-SCS-2, subject to availability and destination.
SMART Transmitter Power Supply/SMART Current Driver. 2-channel signal conditioner, 24 V DC supply (Power Rail), Analog input (AI), Analog output (AO), Operates as transmitter power supply or current driver, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC. Signal type: Analog input/analog output. Safety Integrity Level (SIL): SIL 2. Systematic capability (SC): SC 3. Connection: Power Rail or terminals 9+, 10-. Rated voltage: 19 ... 30 V DC. Ripple: max. 10 %. Rated current: max. 88 mA at 24 V. Power dissipation: max. 1.4 W. Power consumption: max. 2.1 W. Number of channels: 2. Suitable field devices: 2-wire SMART transmitters. Signal: 0/4 ... 20 mA , limited to approx. 30 mA. Field circuit: terminals 1+, 2-, 3+, 4-. Available voltage: min. 15 V at 20 mA min. 18 V at 4 mA. Control circuit: terminals 5-, 6+; 7-, 8+. Input voltage: Voltage across terminals 10 ... 30 V. If the current is supplied from a source > 24 V,series resistance of ≥ (V - 24)/0.02 Ω is needed, where V is the source voltage. The maximum value of the resistance is (V - 10)/0.02 Ω. (sink output). Load: max. 350 Ω (source output). Ripple: 20 mV eff. Number of channels: 2. Suitable field devices: SMART I/P converters (positioner), on-site-displays. Signal: 0/4 ... 20 mA , limited to approx. 30 mA. Field circuit: terminals 1+, 2-, 3+, 4-. Load: max. 650 Ω. Voltage: min. 13 V at 20 mA. Ripple: 20 mV eff , on all signal terminals. Control circuit: terminals 5-, 6+; 7-, 8+. Voltage drop: max. 6 V. Line fault detection: > 100 kΩ at max. 30 V, with field wiring open. Deviation: max. 20 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage. Influence of ambient temperature< 2 µA/K (-40 ... 70 °C (-40 ... 158 °F)): . Influence of ambient temperature: < 2 µA/K (-40 ... 70 °C (-40 ... 158 °F)). Frequency range: field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB). Settling time: max. 200 ms. Rise time/fall time: max. 100 ms (10 ... 90 %). Field circuit/control circuit: basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Control circuit/control circuit: functional isolation, rated voltage: 50 V. Field circuit/power supply: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Control/power supply: basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Display elements: LED. Factory setting: analog input with source output. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017 EN 61326-3-2:2018. Degree of protection: IEC 60529:2001. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP20. Connection: screw terminals. Mass: approx. 115 g. Dimensions: 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2. Height124 mmWidth12.5 mmDepth114 mm: . Height: 124 mm. Width: 12.5 mm. Depth: 114 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Analog input/analog output |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| Systematic capability (SC) | SC 3 |
Supply
| Connection | Power Rail or terminals 9+, 10- |
| Rated voltage | 19 ... 30 V DC Ur |
| Ripple | max. 10 % |
| Rated current | max. 88 mA at 24 V Ir |
| Power dissipation | max. 1.4 W |
| Power consumption | max. 2.1 W |
Analog input
| Number of channels | 2 |
| Suitable field devices | 2-wire SMART transmitters |
| Signal | 0/4 ... 20 mA , limited to approx. 30 mA |
| Field circuit | terminals 1+, 2-, 3+, 4- |
| Available voltage | min. 15 V at 20 mA min. 18 V at 4 mA |
| Control circuit | terminals 5-, 6+; 7-, 8+ |
| Input voltage | Voltage across terminals 10 ... 30 V. If the current is supplied from a source > 24 V,series resistance of ≥ (V - 24)/0.02 Ω is needed, where V is the source voltage. The maximum value of the resistance is (V - 10)/0.02 Ω. (sink output) |
| Load | max. 350 Ω (source output) |
| Ripple | 20 mV eff |
Analog output
| Number of channels | 2 |
| Suitable field devices | SMART I/P converters (positioner), on-site-displays |
| Signal | 0/4 ... 20 mA , limited to approx. 30 mA |
| Field circuit | terminals 1+, 2-, 3+, 4- |
| Load | max. 650 Ω |
| Voltage | min. 13 V at 20 mA |
| Ripple | 20 mV eff , on all signal terminals |
| Control circuit | terminals 5-, 6+; 7-, 8+ |
| Voltage drop | max. 6 V |
| Line fault detection | > 100 kΩ at max. 30 V, with field wiring open |
Transfer characteristics
| Deviation | max. 20 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage |
| Influence of ambient temperature< 2 µA/K (-40 ... 70 °C (-40 ... 158 °F)) | Influence of ambient temperature |
| Influence of ambient temperature | < 2 µA/K (-40 ... 70 °C (-40 ... 158 °F)) |
| Frequency range | field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) |
| Settling time | max. 200 ms |
| Rise time/fall time | max. 100 ms (10 ... 90 %) |
Galvanic isolation
| Field circuit/control circuit | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Control circuit/control circuit | functional isolation, rated voltage: 50 V |
| Field circuit/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Control/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LED |
| Factory setting | analog input with source output |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017 EN 61326-3-2:2018 |
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 115 g |
| Dimensions | 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 |
| Height124 mmWidth12.5 mmDepth114 mm | Height |
| Height | 124 mm |
| Width | 12.5 mm |
| Depth | 114 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |