Available on request

Pepperl Fuchs KCD2-SCD-Ex1.ES

MPN: KCD2-SCD-Ex1.ES · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryK-System (DIN Rail Mounting)
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can KCD2-SCD-Ex1.ES be shipped?

KCD2-SCD-Ex1.ES is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KCD2-SCD-Ex1.ES in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KCD2-SCD-Ex1.ES and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-SCD-Ex1.ES, subject to availability and destination.

SMART Current Driver. 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Safety Integrity Level (SIL): SIL 3, Rated voltage: 19 ... 30 V DC, Signal: 1 x 4 ... 20 mA, Field device: 1 x I/P converters, Field device [2]: 1 x positioner. Signal type: Analog output. Safety Integrity Level (SIL): SIL 3. Connection: Power Rail or terminals 9+, 10-. Rated voltage: 19 ... 30 V DC. Ripple: ≤ 10 %. Rated current: ≤ 33 mA at 24 V. Power dissipation: ≤ 700 mW at 20 mA and 500 Ω load. Power consumption: ≤ 800 mW. Connection side: control side. Connection: terminals 5-, 6+. Input signal: 4 ... 20 mA , limited to approx. 25 mA. Input voltage: open loop voltage of the control system < 30 V, in line fault mode < 60 V. Voltage drop: approx. 6 V at 20 mA. Input resistance: > 100 kΩ, with field wiring open or < 50 Ω. Connection side: field side. Connection: terminals 1+, 2-. Voltage: ≥ 13 V at 20 mA. Current: 4 ... 20 mA. Load: 100 ... 650 Ω. Ripple: 20 mV rms. Line fault detection: field wiring open or < 50 Ω and test current < 2 mA. Deviation: at 20 °C (68 °F), 4 ... 20 mA< 0.1 % of full scale, incl. non-linearity and hysteresis. Influence of ambient temperature< 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)): . Influence of ambient temperature: < 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)). Frequency range: field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 1 mApp signal 0 ... 3 kHz (-3 dB). Rise time: 10 to 90 % ≤ 10 ms. Input/Output: basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Input/power supply: basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Output/power supply: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Display elements: LEDs. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017 EN 61326-3-2:2018. Degree of protection: IEC 60529. Protection against electrical shock: UL 61010-1:2012. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP20. Connection: screw terminals. Mass: approx. 100 g. Dimensions: 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 20 ATEX 016 X. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IOutputEx ia: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Output: Ex ia. Supply: . Maximum safe voltageUm250 V AC (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 250 V AC (Attention! Um is no rated voltage.). Equipment: terminals 1+, 2-. VoltageUo25.2 VCurrentIo100 mAPowerPo630 mWInternal capacitanceCi5.7 nFInternal inductanceLinegligible: Uo. Voltage: 25.2 V. Current: 100 mA. Power: 630 mW. Internal capacitance: 5.7 nF. Internal inductance: negligible. Certificate: CESI 20 ATEX 017 X. Marking II 3G Ex ec IIC T4 Gc: . Marking: II 3G Ex ec IIC T4 Gc. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 VOutput/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Output/power supply: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-7:2015: . Directive 2014/34/EU: EN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-7:2015. UL approval: E106378. Control drawing116-0471 (cULus): . Control drawing: 116-0471 (cULus). IECEx approval: . IECEx certificateIECEx CES 20.0009XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc: . IECEx certificate: IECEx CES 20.0009X. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Signal typeAnalog output

Functional safety related parameters

Safety Integrity Level (SIL)SIL 3

Supply

ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC Ur
Ripple≤ 10 %
Rated current≤ 33 mA at 24 V Ir
Power dissipation≤ 700 mW at 20 mA and 500 Ω load
Power consumption≤ 800 mW

Input

Connection sidecontrol side
Connectionterminals 5-, 6+
Input signal4 ... 20 mA , limited to approx. 25 mA
Input voltageopen loop voltage of the control system < 30 V, in line fault mode < 60 V
Voltage dropapprox. 6 V at 20 mA
Input resistance> 100 kΩ, with field wiring open or < 50 Ω

Output

Connection sidefield side
Connectionterminals 1+, 2-
Voltage≥ 13 V at 20 mA
Current4 ... 20 mA
Load100 ... 650 Ω
Ripple20 mV rms
Line fault detectionfield wiring open or < 50 Ω and test current < 2 mA

Transfer characteristics

Deviationat 20 °C (68 °F), 4 ... 20 mA< 0.1 % of full scale, incl. non-linearity and hysteresis
Influence of ambient temperature< 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)) Influence of ambient temperature
Influence of ambient temperature< 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F))
Frequency rangefield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 1 mApp signal 0 ... 3 kHz (-3 dB)
Rise time10 to 90 % ≤ 10 ms

Galvanic isolation

Input/Outputbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplybasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLEDs
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations) Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2017 EN 61326-3-2:2018
Degree of protectionIEC 60529
Protection against electrical shockUL 61010-1:2012

Ambient conditions

Ambient temperature-40 ... 70 °C (-40 ... 158 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 100 g
Dimensions12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateCESI 20 ATEX 016 X
Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IOutputEx ia Marking
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
OutputEx ia
Supply
Maximum safe voltageUm250 V AC (Attention! Um is no rated voltage.)Um Maximum safe voltage
Maximum safe voltage250 V AC (Attention! Um is no rated voltage.) Um
Equipmentterminals 1+, 2-
VoltageUo25.2 VCurrentIo100 mAPowerPo630 mWInternal capacitanceCi5.7 nFInternal inductanceLinegligibleUo Voltage
Voltage25.2 V Uo
Current100 mA Io
Power630 mW Po
Internal capacitance5.7 nF Ci
Internal inductancenegligible Li
CertificateCESI 20 ATEX 017 X
Marking II 3G Ex ec IIC T4 Gc Marking
MarkingII 3G Ex ec IIC T4 Gc
Galvanic isolation
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 VOutput/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V Input/Output
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Output/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-7:2015 Directive 2014/34/EU
Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-7:2015

International approvals

UL approvalE106378
Control drawing116-0471 (cULus) Control drawing
Control drawing116-0471 (cULus)
IECEx approval
IECEx certificateIECEx CES 20.0009XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc IECEx certificate
IECEx certificateIECEx CES 20.0009X
IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote