Pepperl Fuchs KCD2-RR2-Ex1.SP
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | K-System (DIN Rail Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KCD2-RR2-Ex1.SP be shipped?
KCD2-RR2-Ex1.SP is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KCD2-RR2-Ex1.SP in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KCD2-RR2-Ex1.SP and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-RR2-Ex1.SP, subject to availability and destination.
Resistance Repeater. 1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer. Signal type: Analog input. Safety Integrity Level (SIL): SIL 2. Connection: Power Rail or terminals 9+, 10-. Rated voltage: 19 ... 30 V DC. Ripple: within the supply tolerance. Rated current: < 28 mA. Power consumption: 0.35 W (24 V and 1 mA sense current), 0.85 W (30 V and 10 mA sense current). Connection side: field side. Connection: terminals 1, 2, 3, 4. Line fault detection: yes , at Pt100. Lead resistance: ≤ 10 % of resistance value. Transmission range: 0 ... 10 mA. Available voltage: 7 V. Line fault detection: < 30 nA. Connection side: control side. Connection: terminals 5-, 7-, 6+, 8+. Current: 0 ... 10 mA. Available voltage: 0 ... 4.2 V. Fault signal: field voltage < 150 mV or > 4 V, depending on lead disconnected. Reverse polarity protection: for I < 10 mA or U < 20 V. Accuracy: 0.1 %. Deviation: Im ≥ 1 mA: ±0.1 % of Rm or ± 0.1 Ω (the larger value is applicable) Im < 1 mA: accuracy reduces in proportion to Im. e. g. Im = 0.1 mA: ± 1 % of Rm or 1 Ω (the larger value is applicable).. Influence of ambient temperatureIm ≥ 1 mA, Rm ≥ 100 Ω: 0.01 %/K in the range -20 ... +70 °C (-4 ... 158 °F) Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm: . Influence of ambient temperature: Im ≥ 1 mA, Rm ≥ 100 Ω: 0.01 %/K in the range -20 ... +70 °C (-4 ... 158 °F) Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm. Settling time: ≤ 5 ms. Rise time/fall time: ≤ 2 ms (10 ... 90%). Output/power supply: functional insulation, rated insulation voltage 50 V AC. Display elements: LED. Control elements: DIP switch. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017 EN IEC 61326-3-2:2018. Degree of protection: IEC 60529:2001. Protection against electrical shock: UL 61010-1:2012. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP20. Connection: spring terminals. Mass: approx. 100 g. Dimensions: 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2. Height124 mmWidth12.5 mmDepth114 mm: . Height: 124 mm. Width: 12.5 mm. Depth: 114 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: BASEEFA 10 ATEX 0061X. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IInput[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] IVoltageUo9.5 VCurrentIo39.22 mAPowerPo93 mW: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Input: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I. Voltage: 9.5 V. Current: 39.22 mA. Power: 93 mW. Supply: . Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.). Output: . Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.). Certificate: BASEEFA 10 ATEX 0062X. Marking II 3G Ex ec IIC T4 Gc: . Marking: II 3G Ex ec IIC T4 Gc. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V. Input/power supply: safe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012. FM approval: . FM certificateFM 19 CA 0039 X , FM 19 US 0067 XControl drawing116-0457 (cFMus): . FM certificate: FM 19 CA 0039 X , FM 19 US 0067 X. Control drawing: 116-0457 (cFMus). UL approval: E106378. Control drawing116-0332 (cULus): . Control drawing: 116-0332 (cULus). IECEx approval: . IECEx certificateIECEx BAS 10.0024X IECEx BAS 10.0025XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc: . IECEx certificate: IECEx BAS 10.0024X IECEx BAS 10.0025X. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Analog input |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
Supply
| Connection | Power Rail or terminals 9+, 10- |
| Rated voltage | 19 ... 30 V DC Ur |
| Ripple | within the supply tolerance |
| Rated current | < 28 mA Ir |
| Power consumption | 0.35 W (24 V and 1 mA sense current), 0.85 W (30 V and 10 mA sense current) |
Input
| Connection side | field side |
| Connection | terminals 1, 2, 3, 4 |
| Line fault detection | yes , at Pt100 |
| Lead resistance | ≤ 10 % of resistance value |
| Transmission range | 0 ... 10 mA |
| Available voltage | 7 V |
| Line fault detection | < 30 nA |
Output
| Connection side | control side |
| Connection | terminals 5-, 7-, 6+, 8+ |
| Current | 0 ... 10 mA |
| Available voltage | 0 ... 4.2 V |
| Fault signal | field voltage < 150 mV or > 4 V, depending on lead disconnected |
| Reverse polarity protection | for I < 10 mA or U < 20 V |
Transfer characteristics
| Accuracy | 0.1 % |
| Deviation | Im ≥ 1 mA: ±0.1 % of Rm or ± 0.1 Ω (the larger value is applicable) Im < 1 mA: accuracy reduces in proportion to Im. e. g. Im = 0.1 mA: ± 1 % of Rm or 1 Ω (the larger value is applicable). |
| Influence of ambient temperatureIm ≥ 1 mA, Rm ≥ 100 Ω: 0.01 %/K in the range -20 ... +70 °C (-4 ... 158 °F) Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm | Influence of ambient temperature |
| Influence of ambient temperature | Im ≥ 1 mA, Rm ≥ 100 Ω: 0.01 %/K in the range -20 ... +70 °C (-4 ... 158 °F) Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm |
| Settling time | ≤ 5 ms |
| Rise time/fall time | ≤ 2 ms (10 ... 90%) |
Galvanic isolation
| Output/power supply | functional insulation, rated insulation voltage 50 V AC |
Indicators/settings
| Display elements | LED |
| Control elements | DIP switch |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017 EN IEC 61326-3-2:2018 |
| Degree of protection | IEC 60529:2001 |
| Protection against electrical shock | UL 61010-1:2012 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | spring terminals |
| Mass | approx. 100 g |
| Dimensions | 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 |
| Height124 mmWidth12.5 mmDepth114 mm | Height |
| Height | 124 mm |
| Width | 12.5 mm |
| Depth | 114 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | BASEEFA 10 ATEX 0061X |
| Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IInput[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] IVoltageUo9.5 VCurrentIo39.22 mAPowerPo93 mW | Marking |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Input | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
| Voltage | 9.5 V Uo |
| Current | 39.22 mA Io |
| Power | 93 mW Po |
| Supply | |
| Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) Um |
| Output | |
| Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) Um |
| Certificate | BASEEFA 10 ATEX 0062X |
| Marking II 3G Ex ec IIC T4 Gc | Marking |
| Marking | II 3G Ex ec IIC T4 Gc |
| Galvanic isolation | |
| Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V | Input/Output |
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V |
| Input/power supply | safe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 |
International approvals
| FM approval | |
| FM certificateFM 19 CA 0039 X , FM 19 US 0067 XControl drawing116-0457 (cFMus) | FM certificate |
| FM certificate | FM 19 CA 0039 X , FM 19 US 0067 X |
| Control drawing | 116-0457 (cFMus) |
| UL approval | E106378 |
| Control drawing116-0332 (cULus) | Control drawing |
| Control drawing | 116-0332 (cULus) |
| IECEx approval | |
| IECEx certificateIECEx BAS 10.0024X IECEx BAS 10.0025XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc | IECEx certificate |
| IECEx certificate | IECEx BAS 10.0024X IECEx BAS 10.0025X |
| IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G