Available on request

Pepperl Fuchs KCD2-RR2-Ex1.SP

MPN: KCD2-RR2-Ex1.SP · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryK-System (DIN Rail Mounting)
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can KCD2-RR2-Ex1.SP be shipped?

KCD2-RR2-Ex1.SP is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KCD2-RR2-Ex1.SP in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KCD2-RR2-Ex1.SP and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-RR2-Ex1.SP, subject to availability and destination.

Resistance Repeater. 1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer. Signal type: Analog input. Safety Integrity Level (SIL): SIL 2. Connection: Power Rail or terminals 9+, 10-. Rated voltage: 19 ... 30 V DC. Ripple: within the supply tolerance. Rated current: < 28 mA. Power consumption: 0.35 W (24 V and 1 mA sense current), 0.85 W (30 V and 10 mA sense current). Connection side: field side. Connection: terminals 1, 2, 3, 4. Line fault detection: yes , at Pt100. Lead resistance: ≤ 10 % of resistance value. Transmission range: 0 ... 10 mA. Available voltage: 7 V. Line fault detection: < 30 nA. Connection side: control side. Connection: terminals 5-, 7-, 6+, 8+. Current: 0 ... 10 mA. Available voltage: 0 ... 4.2 V. Fault signal: field voltage < 150 mV or > 4 V, depending on lead disconnected. Reverse polarity protection: for I < 10 mA or U < 20 V. Accuracy: 0.1 %. Deviation: Im ≥ 1 mA: ±0.1 % of Rm or ± 0.1 Ω (the larger value is applicable) Im < 1 mA: accuracy reduces in proportion to Im. e. g. Im = 0.1 mA: ± 1 % of Rm or 1 Ω (the larger value is applicable).. Influence of ambient temperatureIm ≥ 1 mA, Rm ≥ 100 Ω: 0.01 %/K in the range -20 ... +70 °C (-4 ... 158 °F) Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm: . Influence of ambient temperature: Im ≥ 1 mA, Rm ≥ 100 Ω: 0.01 %/K in the range -20 ... +70 °C (-4 ... 158 °F) Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm. Settling time: ≤ 5 ms. Rise time/fall time: ≤ 2 ms (10 ... 90%). Output/power supply: functional insulation, rated insulation voltage 50 V AC. Display elements: LED. Control elements: DIP switch. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017 EN IEC 61326-3-2:2018. Degree of protection: IEC 60529:2001. Protection against electrical shock: UL 61010-1:2012. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP20. Connection: spring terminals. Mass: approx. 100 g. Dimensions: 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2. Height124 mmWidth12.5 mmDepth114 mm: . Height: 124 mm. Width: 12.5 mm. Depth: 114 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: BASEEFA 10 ATEX 0061X. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IInput[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] IVoltageUo9.5 VCurrentIo39.22 mAPowerPo93 mW: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Input: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I. Voltage: 9.5 V. Current: 39.22 mA. Power: 93 mW. Supply: . Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.). Output: . Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.). Certificate: BASEEFA 10 ATEX 0062X. Marking II 3G Ex ec IIC T4 Gc: . Marking: II 3G Ex ec IIC T4 Gc. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V. Input/power supply: safe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012. FM approval: . FM certificateFM 19 CA 0039 X , FM 19 US 0067 XControl drawing116-0457 (cFMus): . FM certificate: FM 19 CA 0039 X , FM 19 US 0067 X. Control drawing: 116-0457 (cFMus). UL approval: E106378. Control drawing116-0332 (cULus): . Control drawing: 116-0332 (cULus). IECEx approval: . IECEx certificateIECEx BAS 10.0024X IECEx BAS 10.0025XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc: . IECEx certificate: IECEx BAS 10.0024X IECEx BAS 10.0025X. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Signal typeAnalog input

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC Ur
Ripplewithin the supply tolerance
Rated current< 28 mA Ir
Power consumption0.35 W (24 V and 1 mA sense current), 0.85 W (30 V and 10 mA sense current)

Input

Connection sidefield side
Connectionterminals 1, 2, 3, 4
Line fault detectionyes , at Pt100
Lead resistance≤ 10 % of resistance value
Transmission range0 ... 10 mA
Available voltage7 V
Line fault detection< 30 nA

Output

Connection sidecontrol side
Connectionterminals 5-, 7-, 6+, 8+
Current0 ... 10 mA
Available voltage0 ... 4.2 V
Fault signalfield voltage < 150 mV or > 4 V, depending on lead disconnected
Reverse polarity protectionfor I < 10 mA or U < 20 V

Transfer characteristics

Accuracy0.1 %
DeviationIm ≥ 1 mA: ±0.1 % of Rm or ± 0.1 Ω (the larger value is applicable) Im < 1 mA: accuracy reduces in proportion to Im. e. g. Im = 0.1 mA: ± 1 % of Rm or 1 Ω (the larger value is applicable).
Influence of ambient temperatureIm ≥ 1 mA, Rm ≥ 100 Ω: 0.01 %/K in the range -20 ... +70 °C (-4 ... 158 °F) Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm Influence of ambient temperature
Influence of ambient temperatureIm ≥ 1 mA, Rm ≥ 100 Ω: 0.01 %/K in the range -20 ... +70 °C (-4 ... 158 °F) Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or Rm
Settling time≤ 5 ms
Rise time/fall time≤ 2 ms (10 ... 90%)

Galvanic isolation

Output/power supplyfunctional insulation, rated insulation voltage 50 V AC

Indicators/settings

Display elementsLED
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations) Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2017 EN IEC 61326-3-2:2018
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1:2012

Ambient conditions

Ambient temperature-40 ... 70 °C (-40 ... 158 °F)

Mechanical specifications

Degree of protectionIP20
Connectionspring terminals
Massapprox. 100 g
Dimensions12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2
Height124 mmWidth12.5 mmDepth114 mm Height
Height124 mm
Width12.5 mm
Depth114 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateBASEEFA 10 ATEX 0061X
Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IInput[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] IVoltageUo9.5 VCurrentIo39.22 mAPowerPo93 mW Marking
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Input[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Voltage9.5 V Uo
Current39.22 mA Io
Power93 mW Po
Supply
Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.)Um Maximum safe voltage
Maximum safe voltage250 V (Attention! The rated voltage can be lower.) Um
Output
Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.)Um Maximum safe voltage
Maximum safe voltage250 V (Attention! The rated voltage can be lower.) Um
CertificateBASEEFA 10 ATEX 0062X
Marking II 3G Ex ec IIC T4 Gc Marking
MarkingII 3G Ex ec IIC T4 Gc
Galvanic isolation
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V Input/Output
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V
Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 Directive 2014/34/EU
Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012

International approvals

FM approval
FM certificateFM 19 CA 0039 X , FM 19 US 0067 XControl drawing116-0457 (cFMus) FM certificate
FM certificateFM 19 CA 0039 X , FM 19 US 0067 X
Control drawing116-0457 (cFMus)
UL approvalE106378
Control drawing116-0332 (cULus) Control drawing
Control drawing116-0332 (cULus)
IECEx approval
IECEx certificateIECEx BAS 10.0024X IECEx BAS 10.0025XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc IECEx certificate
IECEx certificateIECEx BAS 10.0024X IECEx BAS 10.0025X
IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G