Quick facts
| Availability | Confirmed on request |
| Category | K-System (DIN Rail Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KCD0-SD3-Ex2.1545-Y1 be shipped?
KCD0-SD3-Ex2.1545-Y1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KCD0-SD3-Ex2.1545-Y1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KCD0-SD3-Ex2.1545-Y1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD0-SD3-Ex2.1545-Y1, subject to availability and destination.
Solenoid Driver. 2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 15 V DC, Test pulse immunity, Housing width 12.5 mm, Housing width: 12.5 mm, Number of channels: 2-channel, Rated voltage: loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Current: typ. 45 mA, Voltage: ≥ 15 V. Signal type: Digital Output. Rated voltage: loop powered. Power dissipation: < 2 W. Power consumption: . Connection side: control side. Connection: terminals 5+, 6-; 7+, 8- limited electrical values : max. 30 V , max. 5 A. Test pulse length: max. 2 ms from DO card. Signal level: 1-signal: 18 ... 30 V DC 0-signal: 0 ... 5 V DC. Rated voltage: 18 ... 30 V DC. Rated current: 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 20 mA (minimum load current DO card). Inrush current: ≤ 200 mA after 100 µs. Connection side: field side. Connection: terminals 1+, 2-; 3+, 4-. Internal resistor: approx. 167 Ω. Current: typ. 45 mA. Voltage: ≥ 15 V. Current limit: 45 mA. Open loop voltage: typ. 23.8 V. Switching frequency: max. 10 Hz. Energized/De-energized delay: ≤ 20 ms / ≤ 20 ms. Input/Output: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Display elements: LED. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017 , EN IEC 61326-1:2021 (industrial locations) , EN IEC 61326-3-2:2018 For further information see system description.. Degree of protection: IEC 60529:2013. Protection against electrical shock: UL 61010-1:2019. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Degree of protection: IP20. Connection: screw terminals. Mass: approx. 95 g. Dimensions: 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2. Height119 mmWidth12.5 mmDepth114 mm: . Height: 119 mm. Width: 12.5 mm. Depth: 114 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: UL 23 ATEX 3027 X. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IOutputEx ia Refer to certificate for alternative parameters.VoltageUo25.3 VCurrentIo52 mAPowerPo850 mW (angular characteristic curve)Internal resistanceRi167 Ω: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Output: Ex ia Refer to certificate for alternative parameters.. Voltage: 25.3 V. Current: 52 mA. Power: 850 mW (angular characteristic curve). Internal resistance: 167 Ω. Input: . Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.). Certificate: UL 23 ATEX 3065 X. Marking II 3G Ex ec IIC T4 Gc: . Marking: II 3G Ex ec IIC T4 Gc. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012. UL approval: E106378. Control drawing116-0496 (cULus): . Control drawing: 116-0496 (cULus). IECEx approval: . IECEx certificateIECEx ULD 23.0016XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc: . IECEx certificate: IECEx ULD 23.0016X. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Digital Output |
Supply
| Rated voltage | loop powered Ur |
| Power dissipation | < 2 W |
| Power consumption |
Input
| Connection side | control side |
| Connection | terminals 5+, 6-; 7+, 8- limited electrical values : max. 30 V , max. 5 A |
| Test pulse length | max. 2 ms from DO card |
| Signal level | 1-signal: 18 ... 30 V DC 0-signal: 0 ... 5 V DC |
| Rated voltage | 18 ... 30 V DC Ur |
| Rated current | 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 20 mA (minimum load current DO card) Ir |
| Inrush current | ≤ 200 mA after 100 µs |
Output
| Connection side | field side |
| Connection | terminals 1+, 2-; 3+, 4- |
| Internal resistor | approx. 167 Ω Ri |
| Current | typ. 45 mA Ie |
| Voltage | ≥ 15 V Ue |
| Current limit | 45 mA Imax |
| Open loop voltage | typ. 23.8 V Us |
| Switching frequency | max. 10 Hz f |
| Energized/De-energized delay | ≤ 20 ms / ≤ 20 ms |
Galvanic isolation
| Input/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LED |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017 , EN IEC 61326-1:2021 (industrial locations) , EN IEC 61326-3-2:2018 For further information see system description. |
| Degree of protection | IEC 60529:2013 |
| Protection against electrical shock | UL 61010-1:2019 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 95 g |
| Dimensions | 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2 |
| Height119 mmWidth12.5 mmDepth114 mm | Height |
| Height | 119 mm |
| Width | 12.5 mm |
| Depth | 114 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | UL 23 ATEX 3027 X |
| Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IOutputEx ia Refer to certificate for alternative parameters.VoltageUo25.3 VCurrentIo52 mAPowerPo850 mW (angular characteristic curve)Internal resistanceRi167 Ω | Marking |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Output | Ex ia Refer to certificate for alternative parameters. |
| Voltage | 25.3 V Uo |
| Current | 52 mA Io |
| Power | 850 mW (angular characteristic curve) Po |
| Internal resistance | 167 Ω Ri |
| Input | |
| Maximum safe voltageUm250 V (Attention! The rated voltage can be lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) Um |
| Certificate | UL 23 ATEX 3065 X |
| Marking II 3G Ex ec IIC T4 Gc | Marking |
| Marking | II 3G Ex ec IIC T4 Gc |
| Galvanic isolation | |
| Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms | Input/Output |
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 |
International approvals
| UL approval | E106378 |
| Control drawing116-0496 (cULus) | Control drawing |
| Control drawing | 116-0496 (cULus) |
| IECEx approval | |
| IECEx certificateIECEx ULD 23.0016XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc | IECEx certificate |
| IECEx certificate | IECEx ULD 23.0016X |
| IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |