Pepperl Fuchs KCD0-RSH-1.1D.4
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | K-System (DIN Rail Mounting, Highly Functional) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KCD0-RSH-1.1D.4 be shipped?
KCD0-RSH-1.1D.4 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KCD0-RSH-1.1D.4 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KCD0-RSH-1.1D.4 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD0-RSH-1.1D.4, subject to availability and destination.
Relay Module. 1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Up to PL e acc. to EN/ISO 13849, Housing width: 12.5 mm, Number of channels: 1-channel, DTS function (de-energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC loop powered, Type: 1 x logic input. Signal type: Digital Output. Safety Integrity Level (SIL): SIL 3. Systematic capability (SC): SC 3. Performance level (PL): PL e. Connection: loop powered. Rated voltage: 19 ... 30 V DC loop powered. Power dissipation: < 1.3 W. Power consumption: < 1.3 W. Connection side: control side. Connection: Input terminals 5, 6 ; test input terminals 7, 8, 9, 10. Pulse/Pause ratio: 150 ms / 150 ms. Test pulse length: max. 4 ms from DO card. Test input: see functional safety manual. Signal level: 0-signal: -5 ... 5 V 1-signal: 19 ... 26.5 V. Rated current: 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card). Connection side: field side. Connection: terminals 1, 2. Contact loading: 125 V AC/3 A/cos φ 0.7; 30 V DC/3 A resistive load 125 V AC / 1/8 HP. Minimum switch current: 10 mA / 24 V DC. Energized/De-energized delay: 150 ms / 150 ms. Mechanical life: 5 x 106 switching cycles. Switching frequency: < 3 Hz. Input/Output: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff. Display elements: LEDs. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Low voltage: . Directive 2014/35/EUEN 61010-1:2010+A1:2019+A1:2019/AC:2019: . Directive 2014/35/EU: EN 61010-1:2010+A1:2019+A1:2019/AC:2019. Machinery Directive: . Directive 2006/42/ECEN IEC 62061:2021 , EN/ISO 13849-1:2015: . Directive 2006/42/EC: EN IEC 62061:2021 , EN/ISO 13849-1:2015. Electromagnetic compatibility: NE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018. Degree of protection: IEC 60529:2013. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating.. Degree of protection: IP20. Connection: screw terminals. Mass: approx. 100 g. Dimensions: 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Digital Output |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| Systematic capability (SC) | SC 3 |
| Performance level (PL) | PL e |
Supply
| Connection | loop powered |
| Rated voltage | 19 ... 30 V DC loop powered Ur |
| Power dissipation | < 1.3 W |
| Power consumption | < 1.3 W |
Input
| Connection side | control side |
| Connection | Input terminals 5, 6 ; test input terminals 7, 8, 9, 10 |
| Pulse/Pause ratio | 150 ms / 150 ms |
| Test pulse length | max. 4 ms from DO card |
| Test input | see functional safety manual |
| Signal level | 0-signal: -5 ... 5 V 1-signal: 19 ... 26.5 V |
| Rated current | 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card) Ir |
Output
| Connection side | field side |
| Connection | terminals 1, 2 |
| Contact loading | 125 V AC/3 A/cos φ 0.7; 30 V DC/3 A resistive load 125 V AC / 1/8 HP |
| Minimum switch current | 10 mA / 24 V DC |
| Energized/De-energized delay | 150 ms / 150 ms |
| Mechanical life | 5 x 106 switching cycles |
Transfer characteristics
| Switching frequency | < 3 Hz |
Galvanic isolation
| Input/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LEDs |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Low voltage | |
| Directive 2014/35/EUEN 61010-1:2010+A1:2019+A1:2019/AC:2019 | Directive 2014/35/EU |
| Directive 2014/35/EU | EN 61010-1:2010+A1:2019+A1:2019/AC:2019 |
| Machinery Directive | |
| Directive 2006/42/ECEN IEC 62061:2021 , EN/ISO 13849-1:2015 | Directive 2006/42/EC |
| Directive 2006/42/EC | EN IEC 62061:2021 , EN/ISO 13849-1:2015 |
Conformity
| Electromagnetic compatibility | NE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018 |
| Degree of protection | IEC 60529:2013 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating. |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 100 g |
| Dimensions | 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G