Pepperl Fuchs IQH1-FP-V1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | RFID Read/Write Devices |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can IQH1-FP-V1 be shipped?
IQH1-FP-V1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IQH1-FP-V1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IQH1-FP-V1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IQH1-FP-V1, subject to availability and destination.
RFID read/write device. HF RFID read/write device, ISO 15693, for IDENT<i>Control</i>. Operating frequency: 13.56 MHz. Transfer rate: 26 kBit/s. Sensing range: . Read distance0 ... 130 mmWrite distance0 ... 130 mmWidthmax. 100 mm: . Read distance: 0 ... 130 mm. Write distance: 0 ... 130 mm. Width: max. 100 mm. UL File Number: E87056. MTBF: 110 a (Operation at +40 °C). LED green/yellow: green: power ongreen flashing: read/write attempt performedyellow: data carrier detected. Power consumption: ≤ 1.3 W. Supply: from the IDENTControl. Radio equipment: . Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364: . Directive 2014/53/EU: EN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364. RoHS: . Directive 2011/65/EU (RoHS)IEC/EN 63000: . Directive 2011/65/EU (RoHS): IEC/EN 63000. Degree of protection: EN 60529. RFID: ISO/IEC 15693-2 ISO/IEC 15693-3 ISO/IEC 18000-3. FCC approval: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.Caution:Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.. IC approval: This device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause interference, and(2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Degree of protection: IP67. Connection: connector M12 x 1. Material: . HousingPBTBasediecast aluminumEncapsulation compoundCY 221/HY 2966: . Housing: PBT. Base: diecast aluminum. Encapsulation compound: CY 221/HY 2966. Installation: . Distance between two headsMultiplex on: ≥ 100 mm Multiplex off: ≥ 150 mm: . Distance between two heads: Multiplex on: ≥ 100 mm Multiplex off: ≥ 150 mm. Mass: approx. 380 g. Dimensions: . Height40 mmWidth80 mmLength108.5 mm: . Height: 40 mm. Width: 80 mm. Length: 108.5 mm
Specifications
General specifications
| Operating frequency | 13.56 MHz |
| Transfer rate | 26 kBit/s |
| Sensing range | |
| Read distance0 ... 130 mmWrite distance0 ... 130 mmWidthmax. 100 mm | Read distance |
| Read distance | 0 ... 130 mm |
| Write distance | 0 ... 130 mm |
| Width | max. 100 mm |
| UL File Number | E87056 |
| MTBF | 110 a (Operation at +40 °C) |
Indicators/operating means
| LED green/yellow | green: power ongreen flashing: read/write attempt performedyellow: data carrier detected |
Electrical specifications
| Power consumption | ≤ 1.3 W P0 |
| Supply | from the IDENTControl |
Directive conformity
| Radio equipment | |
| Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364 | Directive 2014/53/EU |
| Directive 2014/53/EU | EN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364 |
| RoHS | |
| Directive 2011/65/EU (RoHS)IEC/EN 63000 | Directive 2011/65/EU (RoHS) |
| Directive 2011/65/EU (RoHS) | IEC/EN 63000 |
Standard conformity
| Degree of protection | EN 60529 |
| RFID | ISO/IEC 15693-2 ISO/IEC 15693-3 ISO/IEC 18000-3 |
Approvals and certificates
| FCC approval | This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.Caution:Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. |
| IC approval | This device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause interference, and(2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications
| Degree of protection | IP67 |
| Connection | connector M12 x 1 |
| Material | |
| HousingPBTBasediecast aluminumEncapsulation compoundCY 221/HY 2966 | Housing |
| Housing | PBT |
| Base | diecast aluminum |
| Encapsulation compound | CY 221/HY 2966 |
| Installation | |
| Distance between two headsMultiplex on: ≥ 100 mm Multiplex off: ≥ 150 mm | Distance between two heads |
| Distance between two heads | Multiplex on: ≥ 100 mm Multiplex off: ≥ 150 mm |
| Mass | approx. 380 g |
| Dimensions | |
| Height40 mmWidth80 mmLength108.5 mm | Height |
| Height | 40 mm |
| Width | 80 mm |
| Length | 108.5 mm |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G

