Available on request

Pepperl Fuchs IQH1-FP-V1

MPN: IQH1-FP-V1 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryRFID Read/Write Devices
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can IQH1-FP-V1 be shipped?

IQH1-FP-V1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up IQH1-FP-V1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for IQH1-FP-V1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IQH1-FP-V1, subject to availability and destination.

RFID read/write device. HF RFID read/write device, ISO 15693, for IDENT<i>Control</i>. Operating frequency: 13.56 MHz. Transfer rate: 26 kBit/s. Sensing range: . Read distance0 ... 130 mmWrite distance0 ... 130 mmWidthmax. 100 mm: . Read distance: 0 ... 130 mm. Write distance: 0 ... 130 mm. Width: max. 100 mm. UL File Number: E87056. MTBF: 110 a (Operation at +40 °C). LED green/yellow: green: power ongreen flashing: read/write attempt performedyellow: data carrier detected. Power consumption: ≤ 1.3 W. Supply: from the IDENTControl. Radio equipment: . Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364: . Directive 2014/53/EU: EN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364. RoHS: . Directive 2011/65/EU (RoHS)IEC/EN 63000: . Directive 2011/65/EU (RoHS): IEC/EN 63000. Degree of protection: EN 60529. RFID: ISO/IEC 15693-2 ISO/IEC 15693-3 ISO/IEC 18000-3. FCC approval: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.Caution:Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.. IC approval: This device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause interference, and(2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Degree of protection: IP67. Connection: connector M12 x 1. Material: . HousingPBTBasediecast aluminumEncapsulation compoundCY 221/HY 2966: . Housing: PBT. Base: diecast aluminum. Encapsulation compound: CY 221/HY 2966. Installation: . Distance between two headsMultiplex on: ≥ 100 mm Multiplex off: ≥ 150 mm: . Distance between two heads: Multiplex on: ≥ 100 mm Multiplex off: ≥ 150 mm. Mass: approx. 380 g. Dimensions: . Height40 mmWidth80 mmLength108.5 mm: . Height: 40 mm. Width: 80 mm. Length: 108.5 mm

Specifications

General specifications

Operating frequency13.56 MHz
Transfer rate26 kBit/s
Sensing range
Read distance0 ... 130 mmWrite distance0 ... 130 mmWidthmax. 100 mm Read distance
Read distance0 ... 130 mm
Write distance0 ... 130 mm
Widthmax. 100 mm
UL File NumberE87056
MTBF110 a (Operation at +40 °C)

Indicators/operating means

LED green/yellowgreen: power ongreen flashing: read/write attempt performedyellow: data carrier detected

Electrical specifications

Power consumption≤ 1.3 W P0
Supplyfrom the IDENTControl

Directive conformity

Radio equipment
Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364 Directive 2014/53/EU
Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 300330 EN 62368-1 EN 50364
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000 Directive 2011/65/EU (RoHS)
Directive 2011/65/EU (RoHS)IEC/EN 63000

Standard conformity

Degree of protectionEN 60529
RFIDISO/IEC 15693-2 ISO/IEC 15693-3 ISO/IEC 18000-3

Approvals and certificates

FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.Caution:Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause interference, and(2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Ambient conditions

Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)

Mechanical specifications

Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingPBTBasediecast aluminumEncapsulation compoundCY 221/HY 2966 Housing
HousingPBT
Basediecast aluminum
Encapsulation compoundCY 221/HY 2966
Installation
Distance between two headsMultiplex on: ≥ 100 mm Multiplex off: ≥ 150 mm Distance between two heads
Distance between two headsMultiplex on: ≥ 100 mm Multiplex off: ≥ 150 mm
Massapprox. 380 g
Dimensions
Height40 mmWidth80 mmLength108.5 mm Height
Height40 mm
Width80 mm
Length108.5 mm
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote