Available on request

Pepperl Fuchs HD2-FBPS-1.25.360

MPN: HD2-FBPS-1.25.360 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategorySegment Coupler for PROFIBUS PA
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can HD2-FBPS-1.25.360 be shipped?

HD2-FBPS-1.25.360 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up HD2-FBPS-1.25.360 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for HD2-FBPS-1.25.360 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HD2-FBPS-1.25.360, subject to availability and destination.

Fieldbus Power Supply. Fieldbus power supply, module for fieldbus power hub, 2 segments, simplex, individual modules per segment, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk: Live work on devices in any hazardous area, Transparent, configuration free, Optimized for size and quality, low heat dissipation, IECEx approval, International, Europe, USA, Canada. Design / Mounting: Motherboard based. Installation in hazardous area: Zone 2 / Div. 2. Rated voltage: 19.2 ... 35 V DC. Rated current: 670 ... 360 mA. Power dissipation: typ. 2 W. Rated voltage: 25 ... 28 V. Rated current: 360 ... 10 mA. Short-circuit current: typ. 400 mA. LED ERR: red flashing: overload error at output. LED PWR: Power LED: green if Uout > 25 V. Fieldbus segment/Supply: functional insulation acc. to IEC 62103, rated insulation voltage 250 Veff. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: < 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Core cross section: motherboard specific. Housing material: Polycarbonate. Degree of protection: IP20. Mass: approx. 150 g. Dimensions: . Height106 mmWidth18 mmDepth128 mm: . Height: 106 mm. Width: 18 mm. Depth: 128 mm. Mounting: motherboard mounting. Certificate: TÜV 06 ATEX 553229 X. Marking II 3 G Ex nA IIC T4 Gc: . Marking: II 3 G Ex nA IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-15:2010. FM approval: . FM certificateFM 19 US 0015 X and FM 19 CA 0011 XFM markingClass I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4: . FM certificate: FM 19 US 0015 X and FM 19 CA 0011 X. FM marking: Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4. IECEx approval: . IECEx certificateIECEx TUN 11.0003XIECEx markingEx nA IIC T4 Gc: . IECEx certificate: IECEx TUN 11.0003X. IECEx marking: Ex nA IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Design / MountingMotherboard based
Installation in hazardous areaZone 2 / Div. 2

Supply

Rated voltage19.2 ... 35 V DC Ur
Rated current670 ... 360 mA Ir
Power dissipationtyp. 2 W

Fieldbus connection

Rated voltage25 ... 28 V UN
Rated current360 ... 10 mA IN
Short-circuit currenttyp. 400 mA

Indicators/operating means

LED ERRred flashing: overload error at output
LED PWRPower LED: green if Uout > 25 V

Galvanic isolation

Fieldbus segment/Supplyfunctional insulation acc. to IEC 62103, rated insulation voltage 250 Veff

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013

Standard conformity

Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity< 95 % non-condensing
Shock resistance15 g 11 ms
Vibration resistance1 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Core cross sectionmotherboard specific
Housing materialPolycarbonate
Degree of protectionIP20
Massapprox. 150 g
Dimensions
Height106 mmWidth18 mmDepth128 mm Height
Height106 mm
Width18 mm
Depth128 mm
Mountingmotherboard mounting

Data for application in connection with hazardous areas

CertificateTÜV 06 ATEX 553229 X
Marking II 3 G Ex nA IIC T4 Gc Marking
MarkingII 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-15:2010 Directive 2014/34/EU
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-15:2010

International approvals

FM approval
FM certificateFM 19 US 0015 X and FM 19 CA 0011 XFM markingClass I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4 FM certificate
FM certificateFM 19 US 0015 X and FM 19 CA 0011 X
FM markingClass I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4
IECEx approval
IECEx certificateIECEx TUN 11.0003XIECEx markingEx nA IIC T4 Gc IECEx certificate
IECEx certificateIECEx TUN 11.0003X
IECEx markingEx nA IIC T4 Gc

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote