Pepperl Fuchs GR.CSW*
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Terminal and Junction Boxes (Ex e, Ex i, Ex op) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can GR.CSW* be shipped?
GR.CSW* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up GR.CSW* in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for GR.CSW* and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for GR.CSW*, subject to availability and destination.
Terminal Boxes Ex e, with Window, Glass-Fiber Reinforced Polyester (GRP). Glass-fiber reinforced polyester (GRP) enclosure, Window with flap for time-saving inspection of the internal components, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex eb, Ex ia and Ex tb certified, Withstands temperatures down to -50 °C, Customizable configuration of terminals, cable entries and cable gland types as per specification, Explosion protection: Ex e, Enclosure: carbon loaded, antistatic glass-fiber reinforced polyester (GRP). Operating voltage: 1000 V AC max.. Operating current: application-specific. Enclosure cover: fully detachable , window with flap , optional hinges. Cover fixing: see data table. Screwsstainless steel combination Phillips and slotted screw: . Screws: stainless steel combination Phillips and slotted screw. Cover seal: foamed silicone. Degree of protection: IP66. Cable entry: see data table. Number of cable entriessee data table: . Number of cable entries: see data table. Terminal assembly: . Number of railssee data tableTerminal typeStandard see PDF datasheet, other terminal types optionalNumber of terminals per railsee data table: . Number of rails: see data table. Terminal type: Standard see PDF datasheet, other terminal types optional. Number of terminals per rail: see data table. Material: . Enclosurecarbon loaded, antistatic glass-fiber reinforced polyester (GRP)Finishinherent color blackGrounding plate2 mm or 5 mm brass optional: . Enclosure: carbon loaded, antistatic glass-fiber reinforced polyester (GRP). Finish: inherent color black. Grounding plate: 2 mm or 5 mm brass optional. Mass: see data table valid for empty enclosure, will increase according to integrated components. Dimensions: see data table. Mounting: see data table. Grounding: none as standard optional M6 or M8 internal/external brass nickel-plated grounding bolt optional M6 or M8 internal/external stainless steel grounding bolt. Ambient temperature: -40 ... 55 °C (-40 ... 131 °F). EU-type examination certificate: CML 16 ATEX 3009X. Marking II 2 GD Ex eb IIC T* Gb Ex ib IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T5/T95 °C @ Ta +50 °C T4/T130 °C @ Ta +55 °C: . Marking: II 2 GD Ex eb IIC T* Gb Ex ib IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T5/T95 °C @ Ta +50 °C T4/T130 °C @ Ta +55 °C. IECEx approval: IECEx CML 16.0008X. UKCA approval: CML 22 UKEX 2550X. Degree of protection: EN 60529. CE marking: 0102. Ordering information: This device will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.. Optional accessories: M6 or M8 internal/external brass nickel-plated grounding bolts M6 or M8 internal/external stainless steel grounding bolts grounding plate, brass mounting plate, stainless steel hinges, polyamide mounting block for DIN mounting rail, polyamide engraved traffolyte tag labelengraved AISI 316L stainless steel tag labelcolor in-fill stainless steel tag label
Specifications
Electrical specifications
| Operating voltage | 1000 V AC max. |
| Operating current | application-specific |
Mechanical specifications
| Enclosure cover | fully detachable , window with flap , optional hinges |
| Cover fixing | see data table |
| Screwsstainless steel combination Phillips and slotted screw | Screws |
| Screws | stainless steel combination Phillips and slotted screw |
| Cover seal | foamed silicone |
| Degree of protection | IP66 |
| Cable entry | see data table |
| Number of cable entriessee data table | Number of cable entries |
| Number of cable entries | see data table |
| Terminal assembly | |
| Number of railssee data tableTerminal typeStandard see PDF datasheet, other terminal types optionalNumber of terminals per railsee data table | Number of rails |
| Number of rails | see data table |
| Terminal type | Standard see PDF datasheet, other terminal types optional |
| Number of terminals per rail | see data table |
| Material | |
| Enclosurecarbon loaded, antistatic glass-fiber reinforced polyester (GRP)Finishinherent color blackGrounding plate2 mm or 5 mm brass optional | Enclosure |
| Enclosure | carbon loaded, antistatic glass-fiber reinforced polyester (GRP) |
| Finish | inherent color black |
| Grounding plate | 2 mm or 5 mm brass optional |
| Mass | see data table valid for empty enclosure, will increase according to integrated components |
| Dimensions | see data table |
| Mounting | see data table |
| Grounding | none as standard optional M6 or M8 internal/external brass nickel-plated grounding bolt optional M6 or M8 internal/external stainless steel grounding bolt |
Ambient conditions
| Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) |
Data for application in connection with hazardous areas
| EU-type examination certificate | CML 16 ATEX 3009X |
| Marking II 2 GD Ex eb IIC T* Gb Ex ib IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T5/T95 °C @ Ta +50 °C T4/T130 °C @ Ta +55 °C | Marking |
| Marking | II 2 GD Ex eb IIC T* Gb Ex ib IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T5/T95 °C @ Ta +50 °C T4/T130 °C @ Ta +55 °C |
International approvals
| IECEx approval | IECEx CML 16.0008X |
| UKCA approval | CML 22 UKEX 2550X |
Conformity
| Degree of protection | EN 60529 |
| CE marking | 0102 |
General information
| Ordering information | This device will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Accessories
| Optional accessories | M6 or M8 internal/external brass nickel-plated grounding bolts M6 or M8 internal/external stainless steel grounding bolts grounding plate, brass mounting plate, stainless steel hinges, polyamide mounting block for DIN mounting rail, polyamide engraved traffolyte tag labelengraved AISI 316L stainless steel tag labelcolor in-fill stainless steel tag label |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G