Quick facts
| Availability | Confirmed on request |
| Category | Process Interfaces for PROFIBUS PA |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can F.TI0.P12.*08.P.0.***.***.**00 be shipped?
F.TI0.P12.*08.P.0.***.***.**00 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up F.TI0.P12.*08.P.0.***.***.**00 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for F.TI0.P12.*08.P.0.***.***.**00 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for F.TI0.P12.*08.P.0.***.***.**00, subject to availability and destination.
Temperature Multi-Input Junction Box, Polyester (GRP). 8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, Device coupler location: non-explosion hazardous area<BR>Zone 2 - high-power trunk<BR>Zone 1 - high-power trunk<BR>Zone 1/2 - intrinsically safe high-power trunk<BR>Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunk. Design / Mounting: Outside installation. Installed components: Temperature Multi-Input Device RD0-TI-Ex8.PA.ST For technical data on installed electronic component see data sheet.. Degree of protection: EN 60529. Impact resistance: EN 60079-0. Ambient temperature: -30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request). Storage temperature: -40 ... 70 °C (-40 ... 158 °F). Relative humidity: < 75 % (annual mean)< 95 % (30 d/year), no moisture condensation. Impact resistance: 7J. Enclosure cover: detachable cover with retaining screws. Degree of protection: IP66. Cable entry: cable gland and stopping plug options see separate table. Material: . Housingpolyester , impact resistant, glass fiber reinforcedSurfaceblack molded finish (RAL 9005)Surface resistance< 109 ΩWater absorption< 6 %Sealsilicone , one-pieceGrounding platebrassMaterial thicknessgrounding plate: 3 mm: . Housing: polyester , impact resistant, glass fiber reinforced. Surface: black molded finish (RAL 9005). Surface resistance: < 109 Ω. Water absorption: < 6 %. Seal: silicone , one-piece. Grounding plate: brass. Material thickness: grounding plate: 3 mm. Dimensions: (W x H x D) 271 x 271 x 136 mm (1 x RD0-TI-Ex8.FF.ST). Mounting: thru-holes Ø6.5 mm. Grounding: grounding bolt M6 , Stainless steel. EU-type examination certificate: PTB 07 ATEX 1061 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com. Marking II 2(1)G Ex ia [ia Ga] IIC T4 Gb [exsign] II 2(1)D Ex tb [ia Da] IIIC T135°C Db: . Marking: II 2(1)G Ex ia [ia Ga] IIC T4 Gb [exsign] II 2(1)D Ex tb [ia Da] IIIC T135°C Db. Certificate: PTB 17 ATEX 1011 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com. Marking II 3G Ex ic IIC T4 Gc [exsign] II 3G Ex nA IIC T4 Gc [exsign] II 3D Ex tc IIIC T135°C Dc: . Marking: II 3G Ex ic IIC T4 Gc [exsign] II 3G Ex nA IIC T4 Gc [exsign] II 3D Ex tc IIIC T135°C Dc. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2014: . Directive 2014/34/EU: EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2014. IECEx approval: IECEx PTB 07.0036 X , Zone 1 , suitable Junction Box on request IECEx PTB 09.0016 X , Zone 2 , suitable Junction Box on request. INMETRO approval: TÜV 13.1143. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Outside installation |
| Installed components | Temperature Multi-Input Device RD0-TI-Ex8.PA.ST For technical data on installed electronic component see data sheet. |
Conformity
| Degree of protection | EN 60529 |
| Impact resistance | EN 60079-0 |
Ambient conditions
| Ambient temperature | -30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request) |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Relative humidity | < 75 % (annual mean)< 95 % (30 d/year), no moisture condensation |
| Impact resistance | 7J |
Mechanical specifications
| Enclosure cover | detachable cover with retaining screws |
| Degree of protection | IP66 |
| Cable entry | cable gland and stopping plug options see separate table |
| Material | |
| Housingpolyester , impact resistant, glass fiber reinforcedSurfaceblack molded finish (RAL 9005)Surface resistance< 109 ΩWater absorption< 6 %Sealsilicone , one-pieceGrounding platebrassMaterial thicknessgrounding plate: 3 mm | Housing |
| Housing | polyester , impact resistant, glass fiber reinforced |
| Surface | black molded finish (RAL 9005) |
| Surface resistance | < 109 Ω |
| Water absorption | < 6 % |
| Seal | silicone , one-piece |
| Grounding plate | brass |
| Material thickness | grounding plate: 3 mm |
| Dimensions | (W x H x D) 271 x 271 x 136 mm (1 x RD0-TI-Ex8.FF.ST) |
| Mounting | thru-holes Ø6.5 mm |
| Grounding | grounding bolt M6 , Stainless steel |
Data for application in connection with hazardous areas
| EU-type examination certificate | PTB 07 ATEX 1061 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com |
| Marking II 2(1)G Ex ia [ia Ga] IIC T4 Gb [exsign] II 2(1)D Ex tb [ia Da] IIIC T135°C Db | Marking |
| Marking | II 2(1)G Ex ia [ia Ga] IIC T4 Gb [exsign] II 2(1)D Ex tb [ia Da] IIIC T135°C Db |
| Certificate | PTB 17 ATEX 1011 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com |
| Marking II 3G Ex ic IIC T4 Gc [exsign] II 3G Ex nA IIC T4 Gc [exsign] II 3D Ex tc IIIC T135°C Dc | Marking |
| Marking | II 3G Ex ic IIC T4 Gc [exsign] II 3G Ex nA IIC T4 Gc [exsign] II 3D Ex tc IIIC T135°C Dc |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2014 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2014 |
International approvals
| IECEx approval | IECEx PTB 07.0036 X , Zone 1 , suitable Junction Box on request IECEx PTB 09.0016 X , Zone 2 , suitable Junction Box on request |
| INMETRO approval | TÜV 13.1143 |