Pepperl Fuchs FS-LBAS-IA1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Accessories |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FS-LBAS-IA1 be shipped?
FS-LBAS-IA1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FS-LBAS-IA1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FS-LBAS-IA1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FS-LBAS-IA1, subject to availability and destination.
Surge Protector. FieldConnex®, Surge protector, Ethernet-APL, field mounting, Ex ia, Ex d, Ex e, 20 mm ISO thread, For Ethernet-APL spur ports, Intrinsically safe according to 2-WISE, Stainless steel housing for field device mounting, ISO 20 mm thread. Design / Mounting: Outside installation. Installation in hazardous area: Zone 1. Interface type: Ethernet-APL auxiliary device. Rated voltage: 30 V. Rated current: 500 mA. Impulse rating: 2 kV/1 kA (category C1) per line 5 kV/2,5 kA (category C2) per line 0,5 kA (category D1) per line. Impulse discharge current (10/350 µs): 0.5 kA per line. Nominal discharge current (8/20 µs): . per line2.5 kAtotal5 kA: . per line: 2.5 kA. total: 5 kA. Max. surge current (8/20 µs): 5 kA overstressed fault mode 1 acc. to IEC 61643-21. Voltage protection level: . Line/Earthmax. 1800 V C1 , 1 kA per linemax. 2100 V C2 , 2.5 kA per linemax. 50 V C3 , 50 A per linemax. 1400 V B2 , 50 A per line: . Line/Earth: max. 1800 V C1 , 1 kA per linemax. 2100 V C2 , 2.5 kA per linemax. 50 V C3 , 50 A per linemax. 1400 V B2 , 50 A per line. Degree of protection: IEC/EN 60529. Climatic conditions: IEC 60721. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Surge protection: IEC 61643-21. Ethernet: Ethernet-APL ,IEEE 802.3 for 10BASE-T1L. Ambient temperature: -50 ... 80 °C (-58 ... 176 °F). Storage temperature: -50 ... 90 °C (-58 ... 194 °F). Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Connection type: wire ends APL + red , APL - black , protective conductor (PE) green/yellow. Core cross section: APL +, APL - 0.8 mm2 , PE 1.3 mm2. Housing material: Stainless steel 1.4401/316. Degree of protection: IP67. Mass: 200 g. Mounting: ISO 20 mm. EU-type examination certificate: TÜV 22 ATEX 8786 X. Marking2-WISE auxiliary deviceMarking ll 2 (1) G Ex ia [ia Ga] IIC T6 Gb ,[exsign] ll 2 (1) D Ex ia [ia Da] lIIC T80°C Db ,[exsign] l M2 (M1) Ex ia [ia Ma] l Mb ,[exsign] ll 2 G Ex db eb mb IIC T6 Gb ,[exsign] l M2 Ex eb mb I Mb ,[exsign] lI 2 (1) G Ex db [ia Ga] IIC T6 GbVoltageUi30 VCurrentIi500 mAInternal capacitanceCinegligible 0 nFInternal inductanceLi negligible 0 µH: . Marking: 2-WISE auxiliary device. Marking: ll 2 (1) G Ex ia [ia Ga] IIC T6 Gb ,[exsign] ll 2 (1) D Ex ia [ia Da] lIIC T80°C Db ,[exsign] l M2 (M1) Ex ia [ia Ma] l Mb ,[exsign] ll 2 G Ex db eb mb IIC T6 Gb ,[exsign] l M2 Ex eb mb I Mb ,[exsign] lI 2 (1) G Ex db [ia Ga] IIC T6 Gb. Voltage: 30 V. Current: 500 mA. Internal capacitance: negligible 0 nF. Internal inductance: negligible 0 µH. Directive conformity: . Directive 2014/34/EUEN 60079-0:2018 ,EN 60079-7:2015+A1:2018 ,EN 60079-11:2012 ,EN 60079-18:2015 ,EN 60079-1:2014 ,IEC TS 60079-47:2021: . Directive 2014/34/EU: EN 60079-0:2018 ,EN 60079-7:2015+A1:2018 ,EN 60079-11:2012 ,EN 60079-18:2015 ,EN 60079-1:2014 ,IEC TS 60079-47:2021. IECEx approval: IECEx TUR 22.0017X. Approved forEx ia [ia Ga] IIC T6 Gb ,Ex ia [ia Da] lIIC T80°C Db ,Ex ia [ia Ma] l Mb ,Ex db eb mb IIC T6 Gb ,Ex db eb mb I Mb ,Ex db [ia Ga] IIC T6 Gb: . Approved for: Ex ia [ia Ga] IIC T6 Gb ,Ex ia [ia Da] lIIC T80°C Db ,Ex ia [ia Ma] l Mb ,Ex db eb mb IIC T6 Gb ,Ex db eb mb I Mb ,Ex db [ia Ga] IIC T6 Gb. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Outside installation |
| Installation in hazardous area | Zone 1 |
Ethernet Interface
| Interface type | Ethernet-APL auxiliary device |
Electrical specifications
| Rated voltage | 30 V Ur |
| Rated current | 500 mA Ir |
| Impulse rating | 2 kV/1 kA (category C1) per line 5 kV/2,5 kA (category C2) per line 0,5 kA (category D1) per line |
| Impulse discharge current (10/350 µs) | 0.5 kA per line Iimp |
| Nominal discharge current (8/20 µs) | In |
| per line2.5 kAtotal5 kA | per line |
| per line | 2.5 kA |
| total | 5 kA |
| Max. surge current (8/20 µs) | 5 kA overstressed fault mode 1 acc. to IEC 61643-21 Imax |
| Voltage protection level | Up |
| Line/Earthmax. 1800 V C1 , 1 kA per linemax. 2100 V C2 , 2.5 kA per linemax. 50 V C3 , 50 A per linemax. 1400 V B2 , 50 A per line | Line/Earth |
| Line/Earth | max. 1800 V C1 , 1 kA per linemax. 2100 V C2 , 2.5 kA per linemax. 50 V C3 , 50 A per linemax. 1400 V B2 , 50 A per line |
Standard conformity
| Degree of protection | IEC/EN 60529 |
| Climatic conditions | IEC 60721 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Surge protection | IEC 61643-21 |
| Ethernet | Ethernet-APL ,IEEE 802.3 for 10BASE-T1L |
Ambient conditions
| Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) |
| Storage temperature | -50 ... 90 °C (-58 ... 194 °F) |
| Shock resistance | 15 g 11 ms |
| Vibration resistance | 1 g , 10 ... 150 Hz |
Mechanical specifications
| Connection type | wire ends APL + red , APL - black , protective conductor (PE) green/yellow |
| Core cross section | APL +, APL - 0.8 mm2 , PE 1.3 mm2 |
| Housing material | Stainless steel 1.4401/316 |
| Degree of protection | IP67 |
| Mass | 200 g |
| Mounting | ISO 20 mm |
Data for application in connection with hazardous areas
| EU-type examination certificate | TÜV 22 ATEX 8786 X |
| Marking2-WISE auxiliary deviceMarking ll 2 (1) G Ex ia [ia Ga] IIC T6 Gb ,[exsign] ll 2 (1) D Ex ia [ia Da] lIIC T80°C Db ,[exsign] l M2 (M1) Ex ia [ia Ma] l Mb ,[exsign] ll 2 G Ex db eb mb IIC T6 Gb ,[exsign] l M2 Ex eb mb I Mb ,[exsign] lI 2 (1) G Ex db [ia Ga] IIC T6 GbVoltageUi30 VCurrentIi500 mAInternal capacitanceCinegligible 0 nFInternal inductanceLi negligible 0 µH | Marking |
| Marking | 2-WISE auxiliary device |
| Marking | ll 2 (1) G Ex ia [ia Ga] IIC T6 Gb ,[exsign] ll 2 (1) D Ex ia [ia Da] lIIC T80°C Db ,[exsign] l M2 (M1) Ex ia [ia Ma] l Mb ,[exsign] ll 2 G Ex db eb mb IIC T6 Gb ,[exsign] l M2 Ex eb mb I Mb ,[exsign] lI 2 (1) G Ex db [ia Ga] IIC T6 Gb |
| Voltage | 30 V Ui |
| Current | 500 mA Ii |
| Internal capacitance | negligible 0 nF Ci |
| Internal inductance | negligible 0 µH Li |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2018 ,EN 60079-7:2015+A1:2018 ,EN 60079-11:2012 ,EN 60079-18:2015 ,EN 60079-1:2014 ,IEC TS 60079-47:2021 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2018 ,EN 60079-7:2015+A1:2018 ,EN 60079-11:2012 ,EN 60079-18:2015 ,EN 60079-1:2014 ,IEC TS 60079-47:2021 |
International approvals
| IECEx approval | IECEx TUR 22.0017X |
| Approved forEx ia [ia Ga] IIC T6 Gb ,Ex ia [ia Da] lIIC T80°C Db ,Ex ia [ia Ma] l Mb ,Ex db eb mb IIC T6 Gb ,Ex db eb mb I Mb ,Ex db [ia Ga] IIC T6 Gb | Approved for |
| Approved for | Ex ia [ia Ga] IIC T6 Gb ,Ex ia [ia Da] lIIC T80°C Db ,Ex ia [ia Ma] l Mb ,Ex db eb mb IIC T6 Gb ,Ex db eb mb I Mb ,Ex db [ia Ga] IIC T6 Gb |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |