Available on request

Pepperl Fuchs FOL7250B059

MPN: FOL7250B059 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryFB (Zone 1)
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FOL7250B059 be shipped?

FOL7250B059 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FOL7250B059 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FOL7250B059 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FOL7250B059, subject to availability and destination.

PROFIBUS Fiber Optic Link Coupler and Repeater. For any PROFIBUS interface, e.g. Remote I/O, valves, drives, inverters, motors, controllers etc., Full galvanic isolation between field and control room , No sparks capable of ignition or hot surfaces due to low light energies, Automatic baud rate detection, Star, ring, or line topology selectable, Bridging of great distances while maintaining high transmission rates. Connection: redundant. Rated voltage: 18 ... 32 V , typical: 24 V. Rated current: approx. 200 mA. Power consumption: 4.8 W. Fieldbus type: PROFIBUS DP, DP V1, DP V2, FMS. Terminating resistor: integrated, switchable on. Signal delay: < 6.5 bit times. Interface type: RS-485. Transfer rate: 9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing. Connection: spring terminals, max. 1.5 mm2. Redundancy: HIPER ring. Wave length: 860 nm. Optical input power: min. -28 dBm, max. -3 dBm. Launchable optical power: in multi-mode fiber (50/125): (50/125): -15 dBm (62,5/125): - 13 dBm. Cable length: Multi-mode fiber (MM) 50/125: 3 km with A = 3 dB/km; 3 dB buffer Multi-mode fiber (MM) 62,5/125: with A = 3.5 dB/km; 3 dB buffer. Connector type: BFOC/2.5. Link budget: Multi-mode fiber (MM) 50/125: 13 dB at 860 nmMulti-mode fiber (MM) 62,5/125: 15 dB at 860 nm. Output type: volt-free contact. Switching current: max. 1 A. Switching voltage: max. 32 V. Switch power: max. 30 W. Contact loading: max. 32 V DC, 24 V AC, 1 A (Ex e). PROFIBUS DP/Supply: functional insulation acc. to DIN EN 50178. LED indication: LED System (red/green): Operating voltage and bitrate, LED CH1 (red/yellow): electric channel, LED CH2, CH3 (red/yellow): optic channel. Electromagnetic compatibility: EN 61000-4-2/3/4/5/6, EN 55022, NE 21. Degree of protection: IEC 60529. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: max. 100 % , moisture condensation allowable. Vibration resistance: 1 g , 58 ... 150 Hz according to IEC 60068-2-6. Degree of protection: IP20. Cable: . LengthL200 m ... 1000 m, depending on baud rate: L. Length: 200 m ... 1000 m, depending on baud rate. Mass: 1500 g. Dimensions: 156 x 125 x 75 mm. Mounting: DIN rail mounting. EU-type examination certificate: PTB 07 ATEX 2021 X. Marking II 2 G Ex e mb [ib] op is IIC T4: . Marking: II 2 G Ex e mb [ib] op is IIC T4. Fault indication output: . Maximum safe voltageUm60 V: Um. Maximum safe voltage: 60 V. Directive conformity: . Directive 94/9/ECEN 60079-0:2006 EN 60079-7:2007 EN 60079-11:2007 EN 60079-18:2004 EN 60079-28:2007: . Directive 94/9/EC: EN 60079-0:2006 EN 60079-7:2007 EN 60079-11:2007 EN 60079-18:2004 EN 60079-28:2007. ATEX approval: PTB 07 ATEX 2021X. GOST-R approval: RU C-IT.MIII06.B.00129. INMETRO approval: Brazil: TÜV 14.1594X. Marine approval: . Lloyd Registerc15-20021: . Lloyd Register: c15-20021. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specifications

Supply

Connectionredundant
Rated voltage18 ... 32 V , typical: 24 V Ur
Rated currentapprox. 200 mA Ir
Power consumption4.8 W

Fieldbus connection

Fieldbus typePROFIBUS DP, DP V1, DP V2, FMS
Terminating resistorintegrated, switchable on

Electrical specifications

Signal delay< 6.5 bit times

Interface

Interface typeRS-485
Transfer rate9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing

External bus

Connectionspring terminals, max. 1.5 mm2
RedundancyHIPER ring

Fiber optics functionality

Wave length860 nm
Optical input powermin. -28 dBm, max. -3 dBm
Launchable optical powerin multi-mode fiber (50/125): (50/125): -15 dBm (62,5/125): - 13 dBm
Cable lengthMulti-mode fiber (MM) 50/125: 3 km with A = 3 dB/km; 3 dB buffer Multi-mode fiber (MM) 62,5/125: with A = 3.5 dB/km; 3 dB buffer
Connector typeBFOC/2.5
Link budgetMulti-mode fiber (MM) 50/125: 13 dB at 860 nmMulti-mode fiber (MM) 62,5/125: 15 dB at 860 nm

Fault indication output

Output typevolt-free contact
Switching currentmax. 1 A
Switching voltagemax. 32 V
Switch powermax. 30 W
Contact loadingmax. 32 V DC, 24 V AC, 1 A (Ex e)

Galvanic isolation

PROFIBUS DP/Supplyfunctional insulation acc. to DIN EN 50178

Indicators/settings

LED indicationLED System (red/green): Operating voltage and bitrate, LED CH1 (red/yellow): electric channel, LED CH2, CH3 (red/yellow): optic channel

Conformity

Electromagnetic compatibilityEN 61000-4-2/3/4/5/6, EN 55022, NE 21
Degree of protectionIEC 60529

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humiditymax. 100 % , moisture condensation allowable
Vibration resistance1 g , 58 ... 150 Hz according to IEC 60068-2-6

Mechanical specifications

Degree of protectionIP20
Cable
LengthL200 m ... 1000 m, depending on baud rateL Length
Length200 m ... 1000 m, depending on baud rate L
Mass1500 g
Dimensions156 x 125 x 75 mm
MountingDIN rail mounting

Data for application in connection with hazardous areas

EU-type examination certificatePTB 07 ATEX 2021 X
Marking II 2 G Ex e mb [ib] op is IIC T4 Marking
MarkingII 2 G Ex e mb [ib] op is IIC T4
Fault indication output
Maximum safe voltageUm60 VUm Maximum safe voltage
Maximum safe voltage60 V Um
Directive conformity
Directive 94/9/ECEN 60079-0:2006 EN 60079-7:2007 EN 60079-11:2007 EN 60079-18:2004 EN 60079-28:2007 Directive 94/9/EC
Directive 94/9/ECEN 60079-0:2006 EN 60079-7:2007 EN 60079-11:2007 EN 60079-18:2004 EN 60079-28:2007

International approvals

ATEX approvalPTB 07 ATEX 2021X
GOST-R approvalRU C-IT.MIII06.B.00129
INMETRO approvalBrazil: TÜV 14.1594X
Marine approval
Lloyd Registerc15-20021 Lloyd Register
Lloyd Registerc15-20021

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote