Available on request

Pepperl Fuchs FN-LB-I

MPN: FN-LB-I · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryDevices for Signal Line Protection
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FN-LB-I be shipped?

FN-LB-I is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FN-LB-I in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FN-LB-I and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FN-LB-I, subject to availability and destination.

Surge Protection Barrier. 1-channel, Field mount module, ½ NPT thread, Stainless steel housing, Max. surge current (8/20 µs) 20 kA, 500 V isolation from earth, Suitable for hazardous area, Up to SIL 3 acc. to IEC/EN 61508. Number of protected signal lines: 1. Safety Integrity Level (SIL): SIL 3. Rated voltage: ≤ 48 V. Rated current: ≤ 250 mA. Leakage current: ≤ 5 µA. On-state voltage: ≤ 85 V. Ground insulation: ≥ 500 V breakdown voltage. Total discharge current (8/20 µs): 20 kA. Degree of protection: IEC 60529:2001. Ambient temperature: -30 ... 60 °C (-22 ... 140 °F) For usage in hazardous area observe the EC-type examination certificate.. Housing material: Stainless steel 1.4401 (AISI 316)surface all over polished. Degree of protection: IP67. Cable: . LengthL0.3 m: L. Length: 0.3 m. Mass: approx. 200 g. Dimensions: AF22 x 77 mm (0.9 x 3 inch). Length77 mmWidth across flats22: . Length: 77 mm. Width across flats: 22. Mounting: NPT1/2 thread. EU-type examination certificate: PTB 00 ATEX 2175. Marking II 2G EEx ia IIC T6VoltageUi50 V: . Marking: II 2G EEx ia IIC T6. Voltage: 50 V. Maximum leakage current: 10 kA line to ground (common), 5 kA line to line (differential) in accordance to IEC 60-2. Nominal response time: . Symmetrical1 nsAsymmetric100 ns: . Symmetrical: 1 ns. Asymmetric: 100 ns. Bandwidth: ≥ 40 kHz. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012: . Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012. CSA approval: . Control drawing116-0187 (cCSAus): . Control drawing: 116-0187 (cCSAus). Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Number of protected signal lines1

Functional safety related parameters

Safety Integrity Level (SIL)SIL 3

Supply

Rated voltage≤ 48 V
Rated current≤ 250 mA
Leakage current≤ 5 µA
On-state voltage≤ 85 V
Ground insulation≥ 500 V breakdown voltage

Electrical specifications

Total discharge current (8/20 µs)20 kA

Conformity

Degree of protectionIEC 60529:2001

Ambient conditions

Ambient temperature-30 ... 60 °C (-22 ... 140 °F) For usage in hazardous area observe the EC-type examination certificate.

Mechanical specifications

Housing materialStainless steel 1.4401 (AISI 316)surface all over polished
Degree of protectionIP67
Cable
LengthL0.3 mL
Length0.3 m
Massapprox. 200 g
DimensionsAF22 x 77 mm (0.9 x 3 inch)
Length77 mmWidth across flats22
Length77 mm
Width across flats22
MountingNPT1/2 thread

Data for application in connection with hazardous areas

EU-type examination certificatePTB 00 ATEX 2175
Marking II 2G EEx ia IIC T6VoltageUi50 V
MarkingII 2G EEx ia IIC T6
Voltage50 V
Maximum leakage current10 kA line to ground (common), 5 kA line to line (differential) in accordance to IEC 60-2
Nominal response time
Symmetrical1 nsAsymmetric100 ns
Symmetrical1 ns
Asymmetric100 ns
Bandwidth≥ 40 kHz
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012

International approvals

CSA approval
Control drawing116-0187 (cCSAus)
Control drawing116-0187 (cCSAus)

General information

Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote