Pepperl Fuchs F.FS*.T50.B24.E.*.***.***.****
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Enclosure Solutions |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can F.FS*.T50.B24.E.*.***.***.**** be shipped?
F.FS*.T50.B24.E.*.***.***.**** is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up F.FS*.T50.B24.E.*.***.***.**** in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for F.FS*.T50.B24.E.*.***.***.**** and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for F.FS*.T50.B24.E.*.***.***.****, subject to availability and destination.
Ethernet-APL Rail Field Switch. Ethernet-APL field junction box enclosure solution, brushed stainless steel with intrinsically safe spur ports, Stainless steel enclosure with Ethernet-APL rail field switch, Spur outputs intrinsically safe for Zone 0, 1, or 2, Number of spur outputs selectable, Packaged certified solution, Installation in Zone 2 and Zone 22, Device coupler location: non-explosion hazardous area<BR>Zone 2, Device coupler location [2]: Zone 2. Design / Mounting: Outside installation. Installed components: Ethernet-APL rail field switch ARS1*-B2-I**-** , For technical data on installed electronic component see datasheets.. Fieldbus support: PROFIBUS PA (optional). Degree of protection: EN 60529. Impact resistance: EN 60079-0. Ambient temperature: -40 ... 50 °C (-40 ... 122 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: < 75 % (annual mean)< 95 % (30 d/year), no moisture condensation. Impact resistance: 7J. Enclosure cover: Hinged door with captive retaining screws. Degree of protection: IP66. Cable entry: cable gland and stopping plug options see separate table. Material: . HousingStainless steel 1.4404 / AISI 316LSurfacebrushedSealSilicone, fire-resistant, one piece, foamedMaterial thicknessenclosure body, enclosure cover, mounting plate: 1.5 mm: . Housing: Stainless steel 1.4404 / AISI 316L. Surface: brushed. Seal: Silicone, fire-resistant, one piece, foamed. Material thickness: enclosure body, enclosure cover, mounting plate: 1.5 mm. Dimensions: (W x H x D) 600 x 600 x 260 mm. Mounting: thru-holes Ø 7 mm. Grounding: grounding bolt M6 , brass, nickel-plated. Certificate: PTB 17 ATEX 1011 X. Marking II 3(1) G Ex ic [ia Ga] IIC T4 Gc [exsign] II 3(1)G Ex ec [ia Ga] IIC T4 Gc [exsign] II 3(1)D Ex tc [ia Da] IIIC T135°C Dc: . Marking: II 3(1) G Ex ic [ia Ga] IIC T4 Gc [exsign] II 3(1)G Ex ec [ia Ga] IIC T4 Gc [exsign] II 3(1)D Ex tc [ia Da] IIIC T135°C Dc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014+AC:2018 , EN IEC 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015+Cor.2018 , EN 60079-31:2014: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014+AC:2018 , EN IEC 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015+Cor.2018 , EN 60079-31:2014. IECEx approval: IECEx PTB 07.0036 X , Zone 1 , suitable Junction Box on request IECEx PTB 09.0016 X , Zone 2 , suitable Junction Box on request. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Outside installation |
| Installed components | Ethernet-APL rail field switch ARS1*-B2-I**-** , For technical data on installed electronic component see datasheets. |
| Fieldbus support | PROFIBUS PA (optional) |
Conformity
| Degree of protection | EN 60529 |
| Impact resistance | EN 60079-0 |
Ambient conditions
| Ambient temperature | -40 ... 50 °C (-40 ... 122 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | < 75 % (annual mean)< 95 % (30 d/year), no moisture condensation |
| Impact resistance | 7J |
Mechanical specifications
| Enclosure cover | Hinged door with captive retaining screws |
| Degree of protection | IP66 |
| Cable entry | cable gland and stopping plug options see separate table |
| Material | |
| HousingStainless steel 1.4404 / AISI 316LSurfacebrushedSealSilicone, fire-resistant, one piece, foamedMaterial thicknessenclosure body, enclosure cover, mounting plate: 1.5 mm | Housing |
| Housing | Stainless steel 1.4404 / AISI 316L |
| Surface | brushed |
| Seal | Silicone, fire-resistant, one piece, foamed |
| Material thickness | enclosure body, enclosure cover, mounting plate: 1.5 mm |
| Dimensions | (W x H x D) 600 x 600 x 260 mm |
| Mounting | thru-holes Ø 7 mm |
| Grounding | grounding bolt M6 , brass, nickel-plated |
Data for application in connection with hazardous areas
| Certificate | PTB 17 ATEX 1011 X |
| Marking II 3(1) G Ex ic [ia Ga] IIC T4 Gc [exsign] II 3(1)G Ex ec [ia Ga] IIC T4 Gc [exsign] II 3(1)D Ex tc [ia Da] IIIC T135°C Dc | Marking |
| Marking | II 3(1) G Ex ic [ia Ga] IIC T4 Gc [exsign] II 3(1)G Ex ec [ia Ga] IIC T4 Gc [exsign] II 3(1)D Ex tc [ia Da] IIIC T135°C Dc |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014+AC:2018 , EN IEC 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015+Cor.2018 , EN 60079-31:2014 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014+AC:2018 , EN IEC 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015+Cor.2018 , EN 60079-31:2014 |
International approvals
| IECEx approval | IECEx PTB 07.0036 X , Zone 1 , suitable Junction Box on request IECEx PTB 09.0016 X , Zone 2 , suitable Junction Box on request |
General information
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |