Pepperl Fuchs FDH-1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Advanced Diagnostics |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FDH-1 be shipped?
FDH-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FDH-1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FDH-1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FDH-1, subject to availability and destination.
Fieldbus Diagnostic Handheld. Fieldbus diagnostic handheld for comprehensive diagnostics of the fieldbus physical layer, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, Europe. Design / Mounting: Handheld/mobile. Installation in hazardous area: Zone 1 / Div. 1. Connection: Fieldbus , Battery , 9V 6LR61 block, type alkaline, carbon-zinc, lithium iron disulfide, nickel-cadmium, nickel-metal hydride, or rechargeable lithium , USB. Fieldbus type: FOUNDATION Fieldbus/PROFIBUS PA. Rated voltage: 8.5 ... 35 V. Rated current: ... 10 mA , if bus powered. Display: LC display. Keypad: Membrane 8 keys. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC 60529. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Languages: English (default), German (optional), Portuguese (optional),. Ambient temperature: -20 ... 50 °C (-4 ... 122 °F). Storage temperature: -20 ... 70 °C (-4 ... 158 °F). Relative humidity: < 95 % non-condensing. Shock resistance: 15 g , 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Connection type: Fieldbus: Cable with test clips and cable with test plugs, 2.5 mm Trigger output: Cable with 2 banana plugs USB: Square type B socket. Degree of protection: IP44. Mass: 500 g. EU-type examination certificate: ZELM 14 ATEX 0531. Marking II 2(1) G Ex ib [ia Ga] IIC T4 Gb ,[exsign] II 3(1) G Ex ic [ia Ga] IIC T4 Gc ,[exsign] II 3 G Ex ic IIC T4 Gc ,[exsign] II (1) D [Ex ia IIIC Da] ,[exsign] II (3) D [Ex ic IIIC Dc]: . Marking: II 2(1) G Ex ib [ia Ga] IIC T4 Gb ,[exsign] II 3(1) G Ex ic [ia Ga] IIC T4 Gc ,[exsign] II 3 G Ex ic IIC T4 Gc ,[exsign] II (1) D [Ex ia IIIC Da] ,[exsign] II (3) D [Ex ic IIIC Dc]. Bus: . TypeFieldbusType of protectionia, ibInternal capacitanceCi< 1.8 nFInternal inductanceLi< 1.5 µHVoltage Ui30 V: . Type: Fieldbus. Type of protection: ia, ib. Internal capacitance: < 1.8 nF. Internal inductance: < 1.5 µH. Voltage Ui: 30 V. Bus: . TypeFieldbusType of protectionicInternal capacitance< 1.8 FInternal inductance< 1.5 µHVoltage Ui35 V: . Type: Fieldbus. Type of protection: ic. Internal capacitance: < 1.8 F. Internal inductance: < 1.5 µH. Voltage Ui: 35 V. Outputs: . TypeTrigger outputMaximum safe voltageUm140 V: . Type: Trigger output. Maximum safe voltage: 140 V. Interface: . TypeUSB interfaceMaximum safe voltageUm253 VVoltage Ui6 V: . Type: USB interface. Maximum safe voltage: 253 V. Voltage Ui: 6 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012. CSA approval: CSA 16.70029275. Approved forClass I, Division 2, Groups A, B, C, D, T4Associated equipment for Class I, Division 1, Groups A, B, C, DAssociated equipment for Class II, Division 1, Groups E, F, GAssociated equipment for Class III, Division 1: . Approved for: Class I, Division 2, Groups A, B, C, D, T4Associated equipment for Class I, Division 1, Groups A, B, C, DAssociated equipment for Class II, Division 1, Groups E, F, GAssociated equipment for Class III, Division 1. IECEx approval: IECEx ZLM 14.0012. Approved forEx ib [ia Ga] IIC T4 Gb ,Ex ic [ia Ga] IIC T4 Gc ,Ex ic IIC T4 Gc ,[Ex ia IIIC Da] ,[Ex ic IIIC Dc]: . Approved for: Ex ib [ia Ga] IIC T4 Gb ,Ex ic [ia Ga] IIC T4 Gc ,Ex ic IIC T4 Gc ,[Ex ia IIIC Da] ,[Ex ic IIIC Dc]. Scope of delivery: FDH-1 incl. carrying case, fieldbus connection cable, USB 2.0 cable, FDH-1 Manager software. Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Handheld/mobile |
| Installation in hazardous area | Zone 1 / Div. 1 |
Supply
| Connection | Fieldbus , Battery , 9V 6LR61 block, type alkaline, carbon-zinc, lithium iron disulfide, nickel-cadmium, nickel-metal hydride, or rechargeable lithium , USB |
Fieldbus connection
| Fieldbus type | FOUNDATION Fieldbus/PROFIBUS PA |
| Rated voltage | 8.5 ... 35 V UN |
| Rated current | ... 10 mA , if bus powered IN |
Indicators/operating means
| Display | LC display |
| Keypad | Membrane 8 keys |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity
| Electromagnetic compatibility | NE 21:2011 |
| Degree of protection | IEC 60529 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
Software
| Languages | English (default), German (optional), Portuguese (optional), |
Ambient conditions
| Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) |
| Relative humidity | < 95 % non-condensing |
| Shock resistance | 15 g , 11 ms |
| Vibration resistance | 1 g , 10 ... 150 Hz |
Mechanical specifications
| Connection type | Fieldbus: Cable with test clips and cable with test plugs, 2.5 mm Trigger output: Cable with 2 banana plugs USB: Square type B socket |
| Degree of protection | IP44 |
| Mass | 500 g |
Data for application in connection with hazardous areas
| EU-type examination certificate | ZELM 14 ATEX 0531 |
| Marking II 2(1) G Ex ib [ia Ga] IIC T4 Gb ,[exsign] II 3(1) G Ex ic [ia Ga] IIC T4 Gc ,[exsign] II 3 G Ex ic IIC T4 Gc ,[exsign] II (1) D [Ex ia IIIC Da] ,[exsign] II (3) D [Ex ic IIIC Dc] | Marking |
| Marking | II 2(1) G Ex ib [ia Ga] IIC T4 Gb ,[exsign] II 3(1) G Ex ic [ia Ga] IIC T4 Gc ,[exsign] II 3 G Ex ic IIC T4 Gc ,[exsign] II (1) D [Ex ia IIIC Da] ,[exsign] II (3) D [Ex ic IIIC Dc] |
| Bus | |
| TypeFieldbusType of protectionia, ibInternal capacitanceCi< 1.8 nFInternal inductanceLi< 1.5 µHVoltage Ui30 V | Type |
| Type | Fieldbus |
| Type of protection | ia, ib |
| Internal capacitance | < 1.8 nF Ci |
| Internal inductance | < 1.5 µH Li |
| Voltage Ui | 30 V |
| Bus | |
| TypeFieldbusType of protectionicInternal capacitance< 1.8 FInternal inductance< 1.5 µHVoltage Ui35 V | Type |
| Type | Fieldbus |
| Type of protection | ic |
| Internal capacitance | < 1.8 F |
| Internal inductance | < 1.5 µH |
| Voltage Ui | 35 V |
| Outputs | |
| TypeTrigger outputMaximum safe voltageUm140 V | Type |
| Type | Trigger output |
| Maximum safe voltage | 140 V Um |
| Interface | |
| TypeUSB interfaceMaximum safe voltageUm253 VVoltage Ui6 V | Type |
| Type | USB interface |
| Maximum safe voltage | 253 V Um |
| Voltage Ui | 6 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 |
International approvals
| CSA approval | CSA 16.70029275 |
| Approved forClass I, Division 2, Groups A, B, C, D, T4Associated equipment for Class I, Division 1, Groups A, B, C, DAssociated equipment for Class II, Division 1, Groups E, F, GAssociated equipment for Class III, Division 1 | Approved for |
| Approved for | Class I, Division 2, Groups A, B, C, D, T4Associated equipment for Class I, Division 1, Groups A, B, C, DAssociated equipment for Class II, Division 1, Groups E, F, GAssociated equipment for Class III, Division 1 |
| IECEx approval | IECEx ZLM 14.0012 |
| Approved forEx ib [ia Ga] IIC T4 Gb ,Ex ic [ia Ga] IIC T4 Gc ,Ex ic IIC T4 Gc ,[Ex ia IIIC Da] ,[Ex ic IIIC Dc] | Approved for |
| Approved for | Ex ib [ia Ga] IIC T4 Gb ,Ex ic [ia Ga] IIC T4 Gc ,Ex ic IIC T4 Gc ,[Ex ia IIIC Da] ,[Ex ic IIIC Dc] |
General information
| Scope of delivery | FDH-1 incl. carrying case, fieldbus connection cable, USB 2.0 cable, FDH-1 Manager software |
| Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G