Quick facts

AvailabilityConfirmed on request
CategoryAdvanced Diagnostics
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FDH-1 be shipped?

FDH-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FDH-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FDH-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FDH-1, subject to availability and destination.

Fieldbus Diagnostic Handheld. Fieldbus diagnostic handheld for comprehensive diagnostics of the fieldbus physical layer, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, Europe. Design / Mounting: Handheld/mobile. Installation in hazardous area: Zone 1 / Div. 1. Connection: Fieldbus , Battery , 9V 6LR61 block, type alkaline, carbon-zinc, lithium iron disulfide, nickel-cadmium, nickel-metal hydride, or rechargeable lithium , USB. Fieldbus type: FOUNDATION Fieldbus/PROFIBUS PA. Rated voltage: 8.5 ... 35 V. Rated current: ... 10 mA , if bus powered. Display: LC display. Keypad: Membrane 8 keys. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC 60529. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Languages: English (default), German (optional), Portuguese (optional),. Ambient temperature: -20 ... 50 °C (-4 ... 122 °F). Storage temperature: -20 ... 70 °C (-4 ... 158 °F). Relative humidity: < 95 % non-condensing. Shock resistance: 15 g , 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Connection type: Fieldbus: Cable with test clips and cable with test plugs, 2.5 mm Trigger output: Cable with 2 banana plugs USB: Square type B socket. Degree of protection: IP44. Mass: 500 g. EU-type examination certificate: ZELM 14 ATEX 0531. Marking II 2(1) G Ex ib [ia Ga] IIC T4 Gb ,[exsign] II 3(1) G Ex ic [ia Ga] IIC T4 Gc ,[exsign] II 3 G Ex ic IIC T4 Gc ,[exsign] II (1) D [Ex ia IIIC Da] ,[exsign] II (3) D [Ex ic IIIC Dc]: . Marking: II 2(1) G Ex ib [ia Ga] IIC T4 Gb ,[exsign] II 3(1) G Ex ic [ia Ga] IIC T4 Gc ,[exsign] II 3 G Ex ic IIC T4 Gc ,[exsign] II (1) D [Ex ia IIIC Da] ,[exsign] II (3) D [Ex ic IIIC Dc]. Bus: . TypeFieldbusType of protectionia, ibInternal capacitanceCi< 1.8 nFInternal inductanceLi< 1.5 µHVoltage Ui30 V: . Type: Fieldbus. Type of protection: ia, ib. Internal capacitance: < 1.8 nF. Internal inductance: < 1.5 µH. Voltage Ui: 30 V. Bus: . TypeFieldbusType of protectionicInternal capacitance< 1.8 FInternal inductance< 1.5 µHVoltage Ui35 V: . Type: Fieldbus. Type of protection: ic. Internal capacitance: < 1.8 F. Internal inductance: < 1.5 µH. Voltage Ui: 35 V. Outputs: . TypeTrigger outputMaximum safe voltageUm140 V: . Type: Trigger output. Maximum safe voltage: 140 V. Interface: . TypeUSB interfaceMaximum safe voltageUm253 VVoltage Ui6 V: . Type: USB interface. Maximum safe voltage: 253 V. Voltage Ui: 6 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012. CSA approval: CSA 16.70029275. Approved forClass I, Division 2, Groups A, B, C, D, T4Associated equipment for Class I, Division 1, Groups A, B, C, DAssociated equipment for Class II, Division 1, Groups E, F, GAssociated equipment for Class III, Division 1: . Approved for: Class I, Division 2, Groups A, B, C, D, T4Associated equipment for Class I, Division 1, Groups A, B, C, DAssociated equipment for Class II, Division 1, Groups E, F, GAssociated equipment for Class III, Division 1. IECEx approval: IECEx ZLM 14.0012. Approved forEx ib [ia Ga] IIC T4 Gb ,Ex ic [ia Ga] IIC T4 Gc ,Ex ic IIC T4 Gc ,[Ex ia IIIC Da] ,[Ex ic IIIC Dc]: . Approved for: Ex ib [ia Ga] IIC T4 Gb ,Ex ic [ia Ga] IIC T4 Gc ,Ex ic IIC T4 Gc ,[Ex ia IIIC Da] ,[Ex ic IIIC Dc]. Scope of delivery: FDH-1 incl. carrying case, fieldbus connection cable, USB 2.0 cable, FDH-1 Manager software. Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Design / MountingHandheld/mobile
Installation in hazardous areaZone 1 / Div. 1

Supply

ConnectionFieldbus , Battery , 9V 6LR61 block, type alkaline, carbon-zinc, lithium iron disulfide, nickel-cadmium, nickel-metal hydride, or rechargeable lithium , USB

Fieldbus connection

Fieldbus typeFOUNDATION Fieldbus/PROFIBUS PA
Rated voltage8.5 ... 35 V UN
Rated current... 10 mA , if bus powered IN

Indicators/operating means

DisplayLC display
KeypadMembrane 8 keys

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013

Standard conformity

Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6

Software

LanguagesEnglish (default), German (optional), Portuguese (optional),

Ambient conditions

Ambient temperature-20 ... 50 °C (-4 ... 122 °F)
Storage temperature-20 ... 70 °C (-4 ... 158 °F)
Relative humidity< 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance1 g , 10 ... 150 Hz

Mechanical specifications

Connection typeFieldbus: Cable with test clips and cable with test plugs, 2.5 mm Trigger output: Cable with 2 banana plugs USB: Square type B socket
Degree of protectionIP44
Mass500 g

Data for application in connection with hazardous areas

EU-type examination certificateZELM 14 ATEX 0531
Marking II 2(1) G Ex ib [ia Ga] IIC T4 Gb ,[exsign] II 3(1) G Ex ic [ia Ga] IIC T4 Gc ,[exsign] II 3 G Ex ic IIC T4 Gc ,[exsign] II (1) D [Ex ia IIIC Da] ,[exsign] II (3) D [Ex ic IIIC Dc] Marking
MarkingII 2(1) G Ex ib [ia Ga] IIC T4 Gb ,[exsign] II 3(1) G Ex ic [ia Ga] IIC T4 Gc ,[exsign] II 3 G Ex ic IIC T4 Gc ,[exsign] II (1) D [Ex ia IIIC Da] ,[exsign] II (3) D [Ex ic IIIC Dc]
Bus
TypeFieldbusType of protectionia, ibInternal capacitanceCi< 1.8 nFInternal inductanceLi< 1.5 µHVoltage Ui30 V Type
TypeFieldbus
Type of protectionia, ib
Internal capacitance< 1.8 nF Ci
Internal inductance< 1.5 µH Li
Voltage Ui30 V
Bus
TypeFieldbusType of protectionicInternal capacitance< 1.8 FInternal inductance< 1.5 µHVoltage Ui35 V Type
TypeFieldbus
Type of protectionic
Internal capacitance< 1.8 F
Internal inductance< 1.5 µH
Voltage Ui35 V
Outputs
TypeTrigger outputMaximum safe voltageUm140 V Type
TypeTrigger output
Maximum safe voltage140 V Um
Interface
TypeUSB interfaceMaximum safe voltageUm253 VVoltage Ui6 V Type
TypeUSB interface
Maximum safe voltage253 V Um
Voltage Ui6 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 Directive 2014/34/EU
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012

International approvals

CSA approvalCSA 16.70029275
Approved forClass I, Division 2, Groups A, B, C, D, T4Associated equipment for Class I, Division 1, Groups A, B, C, DAssociated equipment for Class II, Division 1, Groups E, F, GAssociated equipment for Class III, Division 1 Approved for
Approved forClass I, Division 2, Groups A, B, C, D, T4Associated equipment for Class I, Division 1, Groups A, B, C, DAssociated equipment for Class II, Division 1, Groups E, F, GAssociated equipment for Class III, Division 1
IECEx approvalIECEx ZLM 14.0012
Approved forEx ib [ia Ga] IIC T4 Gb ,Ex ic [ia Ga] IIC T4 Gc ,Ex ic IIC T4 Gc ,[Ex ia IIIC Da] ,[Ex ic IIIC Dc] Approved for
Approved forEx ib [ia Ga] IIC T4 Gb ,Ex ic [ia Ga] IIC T4 Gc ,Ex ic IIC T4 Gc ,[Ex ia IIIC Da] ,[Ex ic IIIC Dc]

General information

Scope of deliveryFDH-1 incl. carrying case, fieldbus connection cable, USB 2.0 cable, FDH-1 Manager software
Supplementary informationStatement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote