Pepperl Fuchs FB9215B2
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | FB (Zone 1) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FB9215B2 be shipped?
FB9215B2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FB9215B2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FB9215B2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FB9215B2, subject to availability and destination.
Power supply. Multi range power supply 90 ... 253 V AC, Suitable for the supply of 24 I/O modules and 1 bus coupler, Use two power supplies for redundancy, Installation in suitable enclosures in Zone 1, Voltage: 5.4 V DC +/- 5% , <BR>12 V DC +/- 3%. Bus coupler: 2. I/O modules: >12, depending on the type. Connection: wired to Ex e terminals via backplane. Maximum safe voltage Um: 253 V AC. Input voltage range: 90 ... 253 V AC. Input frequency: 50 ... 60 Hz. Inrush current (< 2 ms): 30 A max. (115 V AC) 50 A max. (230 V AC). Current consumption: 0.95 A (115 V AC) 0.6 A (230 V AC). Voltage: 5.4 V DC +/- 5% , 12 V DC +/- 3%. Power: P5V ≤ 5.4 W, P12V ≤ 39 W - P5V. Power dissipation: approx. 18 % of power consumption. LED indication: LED green: OFF in case of loss of main power or internal voltages (12 V, 5.4 V). Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Low voltage: . Directive 2014/35/EUEN 61010-1: . Directive 2014/35/EU: EN 61010-1. Electromagnetic compatibility: NE 21:2007. Degree of protection: IEC 60529:2000. Environmental test: EN 60068-2-14:2009. Shock resistance: EN 60068-2-27:2009. Vibration resistance: EN 60068-2-6:2008. Damaging gas: EN 60068-2-42:2003. Relative humidity: EN 60068-2-78:2001. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 95 % non-condensing. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , a separate housing is required acc. to the system description. Mass: approx. 890 g. Dimensions: . Height107 mmWidth57 mmDepth132 mm: . Height: 107 mm. Width: 57 mm. Depth: 132 mm. EU-type examination certificate: PTB 97 ATEX 1074 U. Marking II 2 G Ex d IIC Gb: . Marking: II 2 G Ex d IIC Gb. Galvanic isolation: . Output/power supplyEN 60950-1 (safety requirement < 60 V, external power supply SELV/PELV): . Output/power supply: EN 60950-1 (safety requirement < 60 V, external power supply SELV/PELV). Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014. ATEX approval: PTB 97 ATEX 1074 U. IECEx approval: . IECEx marking: . IECEx marking: . System information: The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
Slots
| Bus coupler | 2 |
| I/O modules | >12, depending on the type |
Supply
| Connection | wired to Ex e terminals via backplane |
| Maximum safe voltage Um | 253 V AC |
Input
| Input voltage range | 90 ... 253 V AC |
| Input frequency | 50 ... 60 Hz |
| Inrush current (< 2 ms) | 30 A max. (115 V AC) 50 A max. (230 V AC) |
| Current consumption | 0.95 A (115 V AC) 0.6 A (230 V AC) |
Output
| Voltage | 5.4 V DC +/- 5% , 12 V DC +/- 3% |
| Power | P5V ≤ 5.4 W, P12V ≤ 39 W - P5V |
| Power dissipation | approx. 18 % of power consumption |
Indicators/settings
| LED indication | LED green: OFF in case of loss of main power or internal voltages (12 V, 5.4 V) |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
| Low voltage | |
| Directive 2014/35/EUEN 61010-1 | Directive 2014/35/EU |
| Directive 2014/35/EU | EN 61010-1 |
Conformity
| Electromagnetic compatibility | NE 21:2007 |
| Degree of protection | IEC 60529:2000 |
| Environmental test | EN 60068-2-14:2009 |
| Shock resistance | EN 60068-2-27:2009 |
| Vibration resistance | EN 60068-2-6:2008 |
| Damaging gas | EN 60068-2-42:2003 |
| Relative humidity | EN 60068-2-78:2001 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
| Mass | approx. 890 g |
| Dimensions | |
| Height107 mmWidth57 mmDepth132 mm | Height |
| Height | 107 mm |
| Width | 57 mm |
| Depth | 132 mm |
Data for application in connection with hazardous areas
| EU-type examination certificate | PTB 97 ATEX 1074 U |
| Marking II 2 G Ex d IIC Gb | Marking |
| Marking | II 2 G Ex d IIC Gb |
| Galvanic isolation | |
| Output/power supplyEN 60950-1 (safety requirement < 60 V, external power supply SELV/PELV) | Output/power supply |
| Output/power supply | EN 60950-1 (safety requirement < 60 V, external power supply SELV/PELV) |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 |
International approvals
| ATEX approval | PTB 97 ATEX 1074 U |
| IECEx approval | |
| IECEx marking | IECEx marking |
| IECEx marking |
General information
| System information | The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate. |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G