Pepperl Fuchs FB9205C
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | FB (Zone 1) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FB9205C be shipped?
FB9205C is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FB9205C in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FB9205C and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FB9205C, subject to availability and destination.
Power supply. Power supply for 100 - 230 V AC, Suitable for the supply of FOL, field products (analyzers, level meters etc.), Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Voltage: 24 V DC +/- 3% (Connectors 5, 12) <BR>23 V DC +/- 3% decoupled via diode (Connectors 5, 13). Connection: wired to Ex e terminals. Input voltage range: 90 ... 253 V AC. Power dissipation: 7.9 W. Power consumption: max. 45 VA. Inrush current: 3.4 A (10 ms). Input frequency: 50 ... 60 Hz. Voltage: 24 V DC +/- 3% (Connectors 5, 12) 23 V DC +/- 3% decoupled via diode (Connectors 5, 13). Current: 1.2 A. LED indication: LED green: supply. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Low voltage: . Directive 2014/35/EUEN 61010-1: . Directive 2014/35/EU: EN 61010-1. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Environmental test: EN 60068-2-14. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Damaging gas: EN 60068-2-42. Relative humidity: EN 60068-2-78. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 95 % non-condensing. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , a separate housing is required acc. to the system description. Mass: approx. 890 g. Dimensions: . Height107 mmWidth57 mmDepth132 mm: . Height: 107 mm. Width: 57 mm. Depth: 132 mm. EU-type examination certificate: PTB 97 ATEX 1074 U. Marking II 2 G Ex d IIC Gb: . Marking: II 2 G Ex d IIC Gb. Galvanic isolation: . Output/power supplyEN 60950-1 (safety requirement < 60 V): . Output/power supply: EN 60950-1 (safety requirement < 60 V). Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014. ATEX approval: PTB 97 ATEX 1074 U. System information: The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
Supply
| Connection | wired to Ex e terminals |
| Input voltage range | 90 ... 253 V AC U |
| Power dissipation | 7.9 W |
| Power consumption | max. 45 VA |
| Inrush current | 3.4 A (10 ms) |
Input
| Input frequency | 50 ... 60 Hz |
Output
| Voltage | 24 V DC +/- 3% (Connectors 5, 12) 23 V DC +/- 3% decoupled via diode (Connectors 5, 13) |
| Current | 1.2 A |
Indicators/settings
| LED indication | LED green: supply |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
| Low voltage | |
| Directive 2014/35/EUEN 61010-1 | Directive 2014/35/EU |
| Directive 2014/35/EU | EN 61010-1 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Environmental test | EN 60068-2-14 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Damaging gas | EN 60068-2-42 |
| Relative humidity | EN 60068-2-78 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
| Mass | approx. 890 g |
| Dimensions | |
| Height107 mmWidth57 mmDepth132 mm | Height |
| Height | 107 mm |
| Width | 57 mm |
| Depth | 132 mm |
Data for application in connection with hazardous areas
| EU-type examination certificate | PTB 97 ATEX 1074 U |
| Marking II 2 G Ex d IIC Gb | Marking |
| Marking | II 2 G Ex d IIC Gb |
| Galvanic isolation | |
| Output/power supplyEN 60950-1 (safety requirement < 60 V) | Output/power supply |
| Output/power supply | EN 60950-1 (safety requirement < 60 V) |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 |
International approvals
| ATEX approval | PTB 97 ATEX 1074 U |
General information
| System information | The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate. |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G