Quick facts
| Availability | Confirmed on request |
| Category | FB (Zone 1) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FB8206H0630.3 be shipped?
FB8206H0630.3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FB8206H0630.3 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FB8206H0630.3 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FB8206H0630.3, subject to availability and destination.
EasyCom Com Unit for PROFIBUS DP/DP-V1. Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Installation in suitable enclosures in Zone 1, Fieldbus type: PROFIBUS DP/DP-V1. Occupied slots: 2. Connection: backplane bus. Rated voltage: 5 V DC , only in connection with the power supplies FB92**. Power dissipation: 1.8 W. Power consumption: 1.8 W. Fieldbus type: PROFIBUS DP/DP-V1. PROFIBUS DP: . Connectionwired to Ex e terminals via backplaneBaud rateup to 1.5 MBit/sProtocolPROFIBUS DP/DP V1 read/write services: . Connection: wired to Ex e terminals via backplane. Baud rate: up to 1.5 MBit/s. Protocol: PROFIBUS DP/DP V1 read/write services. Number of stations per bus line: max. 125 (PROFIBUS), max. 119 (service bus). Cyclic process data: 240 bytes input and (simultaneously) 240 bytes output. Number of stations per bus segment: max. 31 (RS-485 standard). Number of repeaters between Master and Slave: max. 3. Supported I/O modules: all FB remote I/O modules. Configuration (240 bytes I/O): Standard: 80 analog, 184 digital Universal 2I2O: 48 analog, 184 digital Universal 4I4O: 60 analog, 120 digital. Bus length: max. 1000 m (FOL, 1.5 MBaud), max. 1000 m (copper cable, 187.5 kBd), max. 200 m (copper cable, 1.5 MBd). Addressing: via configuration software. PROFIBUS address: 0 ... 126 (factory standard setting: 126). GSE file: PFV61711.gsd/gse. HART communication: via PROFIBUS or service bus. Connection: backplane bus. Redundancy: via front connector. LED indication: LED green (power supply): On = operating, fast flash = cold start, slow flash = HCIR loading active LED red (collective alarm): On = internal fault, flashing = no PROFIBUS connection LED yellow (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Environmental test: EN 60068-2-14. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Damaging gas: EN 60068-2-42. Relative humidity: EN 60068-2-78. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 95 % non-condensing. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , a separate housing is required acc. to the system description. Connection: via backplane. Mass: approx. 750 g. Dimensions: . Height107 mmWidth57 mmDepth132 mm: . Height: 107 mm. Width: 57 mm. Depth: 132 mm. EU-type examination certificate: Presafe 19 ATEX 14058U. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012. ATEX approval: Presafe 19 ATEX 14058U. IECEx approval: . IECEx certificateIECEx PRE 19.0013UIECEx markingEx db eb q [ib] IIC Gb: . IECEx certificate: IECEx PRE 19.0013U. IECEx marking: Ex db eb q [ib] IIC Gb. System information: The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
Slots
| Occupied slots | 2 |
Supply
| Connection | backplane bus |
| Rated voltage | 5 V DC , only in connection with the power supplies FB92** Ur |
| Power dissipation | 1.8 W |
| Power consumption | 1.8 W |
Fieldbus connection
| Fieldbus type | PROFIBUS DP/DP-V1 |
| PROFIBUS DP | |
| Connectionwired to Ex e terminals via backplaneBaud rateup to 1.5 MBit/sProtocolPROFIBUS DP/DP V1 read/write services | Connection |
| Connection | wired to Ex e terminals via backplane |
| Baud rate | up to 1.5 MBit/s |
| Protocol | PROFIBUS DP/DP V1 read/write services |
| Number of stations per bus line | max. 125 (PROFIBUS), max. 119 (service bus) |
| Cyclic process data | 240 bytes input and (simultaneously) 240 bytes output |
| Number of stations per bus segment | max. 31 (RS-485 standard) |
| Number of repeaters between Master and Slave | max. 3 |
| Supported I/O modules | all FB remote I/O modules |
| Configuration (240 bytes I/O) | Standard: 80 analog, 184 digital Universal 2I2O: 48 analog, 184 digital Universal 4I4O: 60 analog, 120 digital |
| Bus length | max. 1000 m (FOL, 1.5 MBaud), max. 1000 m (copper cable, 187.5 kBd), max. 200 m (copper cable, 1.5 MBd) |
| Addressing | via configuration software |
| PROFIBUS address | 0 ... 126 (factory standard setting: 126) |
| GSE file | PFV61711.gsd/gse |
| HART communication | via PROFIBUS or service bus |
Internal bus
| Connection | backplane bus |
| Redundancy | via front connector |
Indicators/settings
| LED indication | LED green (power supply): On = operating, fast flash = cold start, slow flash = HCIR loading active LED red (collective alarm): On = internal fault, flashing = no PROFIBUS connection LED yellow (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Fieldbus standard | IEC 61158-2 |
| Environmental test | EN 60068-2-14 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Damaging gas | EN 60068-2-42 |
| Relative humidity | EN 60068-2-78 |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
| Connection | via backplane |
| Mass | approx. 750 g |
| Dimensions | |
| Height107 mmWidth57 mmDepth132 mm | Height |
| Height | 107 mm |
| Width | 57 mm |
| Depth | 132 mm |
Data for application in connection with hazardous areas
| EU-type examination certificate | Presafe 19 ATEX 14058U |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012 |
International approvals
| ATEX approval | Presafe 19 ATEX 14058U |
| IECEx approval | |
| IECEx certificateIECEx PRE 19.0013UIECEx markingEx db eb q [ib] IIC Gb | IECEx certificate |
| IECEx certificate | IECEx PRE 19.0013U |
| IECEx marking | Ex db eb q [ib] IIC Gb |
General information
| System information | The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate. |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G