Quick facts

AvailabilityConfirmed on request
CategoryFB (Zone 1)
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FB1308B3 be shipped?

FB1308B3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FB1308B3 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FB1308B3 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FB1308B3, subject to availability and destination.

Digital Input. 8-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex e connection, Connection: NAMUR sensor, Connection [2]: volt-free contact, Connection [3]: active binary signal 24 V DC. Occupied slots: 2. Connection: backplane bus. Rated voltage: 12 V DC , only in connection with the power supplies FB92**. Power dissipation: 0.95 W. Power consumption: 0.95 W. Connection: backplane bus. Interface: manufacturer-specific bus to standard com unit. Number of channels: 8. Sensor interface: . ConnectionNAMUR sensorConnection [2]volt-free contactConnection [3]active binary signal 24 V DC: . Connection: NAMUR sensor. Connection [2]: volt-free contact. Connection [3]: active binary signal 24 V DC. Connection: channel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8-; channel V: 9+, 10-; channel VI: 11+, 12-; channel VII: 13+, 14-; channel VIII: 15+, 16-. Rated values: acc. to EN 60947-5-6 (NAMUR). Switching point/switching hysteresis: 1.2 ... 2.1 mA / ± 0.2 mA. Internal resistor: 1 kΩ. Line fault detection: can be switched on/off for each channel via configuration tool , active signals (24 V, 5 V) without line fault detection. Connectionmechanical switch with additional resistors (see connection diagram) proximity sensors without additional wiringShort-circuit< 360 ΩOpen-circuit< 0.35 mA: . Connection: mechanical switch with additional resistors (see connection diagram) proximity sensors without additional wiring. Short-circuit: < 360 Ω. Open-circuit: < 0.35 mA. Digital signals (active): configurable 24 V 5 V. Switching point: ON> 8 V > 2.7 VSwitching point: OFF< 3 V < 2.3 V: . Switching point: ON: > 8 V > 2.7 V. Switching point: OFF: < 3 V < 2.3 V. Minimum pulse duration: 1 ms. LED indication: LED green: supply LED red: line fault , red flashing: communication error. Coding: optional mechanical coding via front socket. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Degree of protection: IEC 60529:2000. Environmental test: EN 60068-2-14:2009. Shock resistance: EN 60068-2-27:2009. Vibration resistance: EN 60068-2-6:2008. Damaging gas: EN 60068-2-42:2003. Relative humidity: EN 60068-2-78:2001. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 95 % non-condensing. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , a separate housing is required acc. to the system description. Connection: Ex e spring terminal with protective cover. Mass: approx. 750 g. Dimensions: . Height107 mmWidth57 mmDepth132 mm: . Height: 107 mm. Width: 57 mm. Depth: 132 mm. EU-type examination certificate: FIDI 21 ATEX 0012 U. Marking II 2G Ex db eb q IIC Gb: . Marking: II 2G Ex db eb q IIC Gb. Galvanic isolation: . Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11:2007 , voltage peak value 375 V: . Input/power supply, internal bus: safe electrical isolation acc. to EN 60079-11:2007 , voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018: . Directive 2014/34/EU: EN 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018. ATEX approval: FIDI 21 ATEX 0012 U. IECEx approval: . IECEx certificateIECEx FIDI 21.0002UIECEx markingEx db eb q IIC Gb: . IECEx certificate: IECEx FIDI 21.0002U. IECEx marking: Ex db eb q IIC Gb. System information: The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Specifications

Slots

Occupied slots2

Supply

Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies FB92** Ur
Power dissipation0.95 W
Power consumption0.95 W

Internal bus

Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit

Digital input

Number of channels8
Sensor interface
ConnectionNAMUR sensorConnection [2]volt-free contactConnection [3]active binary signal 24 V DC Connection
ConnectionNAMUR sensor
Connection [2]volt-free contact
Connection [3]active binary signal 24 V DC
Connectionchannel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8-; channel V: 9+, 10-; channel VI: 11+, 12-; channel VII: 13+, 14-; channel VIII: 15+, 16-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Switching point/switching hysteresis1.2 ... 2.1 mA / ± 0.2 mA
Internal resistor1 kΩ Ri
Line fault detectioncan be switched on/off for each channel via configuration tool , active signals (24 V, 5 V) without line fault detection
Connectionmechanical switch with additional resistors (see connection diagram) proximity sensors without additional wiringShort-circuit< 360 ΩOpen-circuit< 0.35 mA Connection
Connectionmechanical switch with additional resistors (see connection diagram) proximity sensors without additional wiring
Short-circuit< 360 Ω
Open-circuit< 0.35 mA
Digital signals (active)configurable 24 V 5 V
Switching point: ON> 8 V > 2.7 VSwitching point: OFF< 3 V < 2.3 V Switching point: ON
Switching point: ON> 8 V > 2.7 V
Switching point: OFF< 3 V < 2.3 V
Minimum pulse duration1 ms

Indicators/settings

LED indicationLED green: supply LED red: line fault , red flashing: communication error
Codingoptional mechanical coding via front socket

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013

Conformity

Degree of protectionIEC 60529:2000
Environmental testEN 60068-2-14:2009
Shock resistanceEN 60068-2-27:2009
Vibration resistanceEN 60068-2-6:2008
Damaging gasEN 60068-2-42:2003
Relative humidityEN 60068-2-78:2001

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
ConnectionEx e spring terminal with protective cover
Massapprox. 750 g
Dimensions
Height107 mmWidth57 mmDepth132 mm Height
Height107 mm
Width57 mm
Depth132 mm

Data for application in connection with hazardous areas

EU-type examination certificateFIDI 21 ATEX 0012 U
Marking II 2G Ex db eb q IIC Gb Marking
MarkingII 2G Ex db eb q IIC Gb
Galvanic isolation
Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11:2007 , voltage peak value 375 V Input/power supply, internal bus
Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11:2007 , voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 Directive 2014/34/EU
Directive 2014/34/EUEN 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018

International approvals

ATEX approvalFIDI 21 ATEX 0012 U
IECEx approval
IECEx certificateIECEx FIDI 21.0002UIECEx markingEx db eb q IIC Gb IECEx certificate
IECEx certificateIECEx FIDI 21.0002U
IECEx markingEx db eb q IIC Gb

General information

System informationThe module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote