Quick facts
| Availability | Confirmed on request |
| Category | Process Interfaces for FOUNDATION Fieldbus H1 |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can F2D0-MIO-Ex12.FF.* be shipped?
F2D0-MIO-Ex12.FF.* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up F2D0-MIO-Ex12.FF.* in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for F2D0-MIO-Ex12.FF.* and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for F2D0-MIO-Ex12.FF.*, subject to availability and destination.
Multi-Input/Output. Multi-input/output for digital signals, stand-alone device with aluminum housing for field installation, For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada. Design / Mounting: Outside installation. Installation in hazardous area: Zone 1 / Div. 1. Electronic component: Binary multi-input/output R8D0-MIO-Ex12.FF* For technical data on installed electronic component see datasheet.. Fieldbus type: FOUNDATION Fieldbus. Number of inputs: 12. Foundation Fieldbus/Field circuit: safe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Low voltage: . Directive 2014/35/EUEN 61010-1:2010: . Directive 2014/35/EU: EN 61010-1:2010. Galvanic isolation: EN 60079-11. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F) hazardous area. Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: ≤ 95 % non-condensing. Shock resistance: 15 g , 11 ms. Vibration resistance: 10 g , 10 ... 150 Hz. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Connection type: plug-in terminals , spring terminal and screw terminal. Core cross section: . Busup to 2.5 mm2Inputsup to 2.5 mm2: . Bus: up to 2.5 mm2. Inputs: up to 2.5 mm2. Cable diameter: see table 2. Cable gland: sensor inputs M16, fieldbus M20. Housing material: Aluminum. Degree of protection: IP66. Mass: 1800 g. Mounting: wall mounting. EU-type examination certificate: BVS 16 ATEX E 075 X. Marking II 2 (1) G Ex ib [ia Ga] IIC T4 Gb , [exsign] II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , [exsign] II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , [exsign] I (M1) [Ex ia Ma] I , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 2 (1) D Ex tb [ia Da] IIIC T130 °C Db: . Marking: II 2 (1) G Ex ib [ia Ga] IIC T4 Gb , [exsign] II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , [exsign] II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , [exsign] I (M1) [Ex ia Ma] I , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 2 (1) D Ex tb [ia Da] IIIC T130 °C Db. Bus: FISCO see EC-Type Examination Certificate. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014: . Directive 2014/34/EU: EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014. FM approval: pending. IECEx approval: IECEx BVS 16.0051X. Approved forEx ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ec [ia Ga] IIC T4 Gc , [Ex ia Ma] I , [Ex ia Da] IIIC , Ex tb [ia Da] IIIC T130 °C Db: . Approved for: Ex ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ec [ia Ga] IIC T4 Gc , [Ex ia Ma] I , [Ex ia Da] IIIC , Ex tb [ia Da] IIIC T130 °C Db. Marine approval: pending. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Outside installation |
| Installation in hazardous area | Zone 1 / Div. 1 |
| Electronic component | Binary multi-input/output R8D0-MIO-Ex12.FF* For technical data on installed electronic component see datasheet. |
Fieldbus connection
| Fieldbus type | FOUNDATION Fieldbus |
Digital input
| Number of inputs | 12 |
Galvanic isolation
| Foundation Fieldbus/Field circuit | safe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
| Low voltage | |
| Directive 2014/35/EUEN 61010-1:2010 | Directive 2014/35/EU |
| Directive 2014/35/EU | EN 61010-1:2010 |
Standard conformity
| Galvanic isolation | EN 60079-11 |
| Electromagnetic compatibility | NE 21:2011 |
| Degree of protection | IEC 60529 |
| Fieldbus standard | IEC 61158-2 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) hazardous area |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | ≤ 95 % non-condensing |
| Shock resistance | 15 g , 11 ms |
| Vibration resistance | 10 g , 10 ... 150 Hz |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Connection type | plug-in terminals , spring terminal and screw terminal |
| Core cross section | |
| Busup to 2.5 mm2Inputsup to 2.5 mm2 | Bus |
| Bus | up to 2.5 mm2 |
| Inputs | up to 2.5 mm2 |
| Cable diameter | see table 2 |
| Cable gland | sensor inputs M16, fieldbus M20 |
| Housing material | Aluminum |
| Degree of protection | IP66 |
| Mass | 1800 g |
| Mounting | wall mounting |
Data for application in connection with hazardous areas
| EU-type examination certificate | BVS 16 ATEX E 075 X |
| Marking II 2 (1) G Ex ib [ia Ga] IIC T4 Gb , [exsign] II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , [exsign] II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , [exsign] I (M1) [Ex ia Ma] I , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 2 (1) D Ex tb [ia Da] IIIC T130 °C Db | Marking |
| Marking | II 2 (1) G Ex ib [ia Ga] IIC T4 Gb , [exsign] II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , [exsign] II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , [exsign] I (M1) [Ex ia Ma] I , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 2 (1) D Ex tb [ia Da] IIIC T130 °C Db |
| Bus | FISCO see EC-Type Examination Certificate |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014 |
International approvals
| FM approval | pending |
| IECEx approval | IECEx BVS 16.0051X |
| Approved forEx ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ec [ia Ga] IIC T4 Gc , [Ex ia Ma] I , [Ex ia Da] IIIC , Ex tb [ia Da] IIIC T130 °C Db | Approved for |
| Approved for | Ex ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ec [ia Ga] IIC T4 Gc , [Ex ia Ma] I , [Ex ia Da] IIIC , Ex tb [ia Da] IIIC T130 °C Db |
Certificates and approvals
| Marine approval | pending |
General information
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G