Available on request

Pepperl Fuchs F*-LBF-I1.32

MPN: F*-LBF-I1.32 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategorySurge Protection
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can F*-LBF-I1.32 be shipped?

F*-LBF-I1.32 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up F*-LBF-I1.32 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for F*-LBF-I1.32 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for F*-LBF-I1.32, subject to availability and destination.

Surge Protector. Surge protector, threaded, for installation via threaded inlet in field housing (Ex ia), IP67, Surge Protector in stainless steel housing, Intrinsically safe, FISCO or Entity, Surge protection for '+' and '-' fieldbus lead, Choice of threads 20 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, Device coupler location: Zone 2 - high-power trunk<BR>Zone 1 - high-power trunk<BR>Zone 1/2 - intrinsically safe high-power trunk<BR>Zone 1 - intrinsically safe trunk. Design / Mounting: Outside installation. Installation in hazardous area: Zone 1. Rated voltage: 32 V. Rated current: 550 mA. Nominal discharge current (8/20 µs): . per line10 kAtotal10 kA: . per line: 10 kA. total: 10 kA. Max. surge current (8/20 µs): 10 kA. Voltage protection level at max. rated current: . Line/Line58 VLine/Earth1700 V: . Line/Line: 58 V. Line/Earth: 1700 V. Voltage protection level at 1 kV/µsec: . Line/Line50 VLine/Earth1.2 kV: . Line/Line: 50 V. Line/Earth: 1.2 kV. Reaction time: . Line/Linemax. 1 nsLine/Earthmax. 100 ns: . Line/Line: max. 1 ns. Line/Earth: max. 100 ns. Capacitance: . Line/Line25 pFLine/Earth15 pF: . Line/Line: 25 pF. Line/Earth: 15 pF. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21:2006. Degree of protection: IEC/EN 60529. Fieldbus standard: IEC 61158-2. Surge protection: IEC 61643-21. Ambient temperature: -50 ... 80 °C (-58 ... 176 °F). Storage temperature: -50 ... 85 °C (-58 ... 185 °F). Core cross section: 1.3 mm2. Housing material: Stainless steel 1.4401/316. Degree of protection: IP00/IP67 if correctly installed. Mass: 160 g. Mounting: screw mounting. EU-type examination certificate: KEMA 04 ATEX 1317 X. Marking II 2(1)G Ex ia [ia Ga] IIC T6...T5 GbVoltageUiEntity 30 V , FISCO 17.5 VCurrentIiEntity 550 mA , FISCO 380 mAPowerPiEntity 3 W , FISCO 5.32 WInternal capacitanceCinegligible 0 nFInternal inductanceLi negligible 0 µH: . Marking: II 2(1)G Ex ia [ia Ga] IIC T6...T5 Gb. Voltage: Entity 30 V , FISCO 17.5 V. Current: Entity 550 mA , FISCO 380 mA. Power: Entity 3 W , FISCO 5.32 W. Internal capacitance: negligible 0 nF. Internal inductance: negligible 0 µH. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012. IECEx approval: . IECEx certificateIECEx KEM 09.0081XIECEx markingEx ia [ia Ga] IIC T6...T5 Gb: . IECEx certificate: IECEx KEM 09.0081X. IECEx marking: Ex ia [ia Ga] IIC T6...T5 Gb. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Design / MountingOutside installation
Installation in hazardous areaZone 1

Electrical specifications

Rated voltage32 V Ur
Rated current550 mA Ir
Nominal discharge current (8/20 µs) In
per line10 kAtotal10 kA per line
per line10 kA
total10 kA
Max. surge current (8/20 µs)10 kA Imax
Voltage protection level at max. rated current
Line/Line58 VLine/Earth1700 V Line/Line
Line/Line58 V
Line/Earth1700 V
Voltage protection level at 1 kV/µsec
Line/Line50 VLine/Earth1.2 kV Line/Line
Line/Line50 V
Line/Earth1.2 kV
Reaction time tA
Line/Linemax. 1 nsLine/Earthmax. 100 ns Line/Line
Line/Linemax. 1 ns
Line/Earthmax. 100 ns
Capacitance
Line/Line25 pFLine/Earth15 pF Line/Line
Line/Line25 pF
Line/Earth15 pF

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013

Standard conformity

Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC/EN 60529
Fieldbus standardIEC 61158-2
Surge protectionIEC 61643-21

Ambient conditions

Ambient temperature-50 ... 80 °C (-58 ... 176 °F)
Storage temperature-50 ... 85 °C (-58 ... 185 °F)

Mechanical specifications

Core cross section1.3 mm2
Housing materialStainless steel 1.4401/316
Degree of protectionIP00/IP67 if correctly installed
Mass160 g
Mountingscrew mounting

Data for application in connection with hazardous areas

EU-type examination certificateKEMA 04 ATEX 1317 X
Marking II 2(1)G Ex ia [ia Ga] IIC T6...T5 GbVoltageUiEntity 30 V , FISCO 17.5 VCurrentIiEntity 550 mA , FISCO 380 mAPowerPiEntity 3 W , FISCO 5.32 WInternal capacitanceCinegligible 0 nFInternal inductanceLi negligible 0 µH Marking
MarkingII 2(1)G Ex ia [ia Ga] IIC T6...T5 Gb
VoltageEntity 30 V , FISCO 17.5 V Ui
CurrentEntity 550 mA , FISCO 380 mA Ii
PowerEntity 3 W , FISCO 5.32 W Pi
Internal capacitancenegligible 0 nF Ci
Internal inductancenegligible 0 µH Li
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 Directive 2014/34/EU
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012

International approvals

IECEx approval
IECEx certificateIECEx KEM 09.0081XIECEx markingEx ia [ia Ga] IIC T6...T5 Gb IECEx certificate
IECEx certificateIECEx KEM 09.0081X
IECEx markingEx ia [ia Ga] IIC T6...T5 Gb

General information

Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote