Pepperl Fuchs F*-FT-Ex1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Accessories |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can F*-FT-Ex1 be shipped?
F*-FT-Ex1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up F*-FT-Ex1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for F*-FT-Ex1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for F*-FT-Ex1, subject to availability and destination.
Fieldbus Terminator. Fieldbus terminator, threaded, for installation via threaded inlet in field housing (Ex ia / Ex d), IP67, Terminator in stainless steel housing, Intrinsically safe, FISCO and flameproof enclosure (Ex d), Installation on open cable gland, Choice of threads 20 mm, Pg 13.5 mm or 1/2" NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, Canada. Design / Mounting: Outside installation. Installation in hazardous area: Zone 1 / Div. 1. Connection: 2-wire cable, red+, black-. Rated voltage: max. 32 V DC. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC/EN 60529. Fieldbus standard: IEC 61158-2. Ambient temperature: -50 ... 85 °C (-58 ... 185 °F). Storage temperature: -50 ... 85 °C (-58 ... 185 °F). Core cross section: 0.75 mm2. Housing: 77 mm x 22 mm. Housing material: Stainless steel 1.4401/316. Degree of protection: IP67. Mass: 100 g. Mounting: 20 mm ISO thread PG13.5 thread 1/2 NPT thread. EU-type examination certificate: DMT 01 ATEX 104 X. Marking II 1G Ex ia IIC T6 ... T4 Ga , [exsign] II 2G Ex db ia IIC T6 ... T4 Gb , [exsign] II 2G Ex db mb IIC T6 ... T4 Gb , max. permissible explosion (reference) pressure of the Ex d enclosure: 20 barTemperature classT6 for ambient temperature ≤ 60 °CT5 for ambient temperature ≤ 75 °CT4 for ambient temperature ≤ 85 °C: . Marking: II 1G Ex ia IIC T6 ... T4 Ga , [exsign] II 2G Ex db ia IIC T6 ... T4 Gb , [exsign] II 2G Ex db mb IIC T6 ... T4 Gb , max. permissible explosion (reference) pressure of the Ex d enclosure: 20 bar. Temperature class: T6 for ambient temperature ≤ 60 °CT5 for ambient temperature ≤ 75 °CT4 for ambient temperature ≤ 85 °C. Maximum values: acc. to FISCO. Directive conformity: . Directive 2014/34/EUEN 60079-0:2012 , EN 60079-1:2014 , EN 60079-11:2012 , EN 60079-18:2015: . Directive 2014/34/EU: EN 60079-0:2012 , EN 60079-1:2014 , EN 60079-11:2012 , EN 60079-18:2015. IECEx approval: IECEx BVS 10.0022X. Approved forEx ia IIC T6 ... T4 Ga , Ex db ia IIC T6 ... T4 Gb , Ex db mb IIC T6 ... T4 Gb: . Approved for: Ex ia IIC T6 ... T4 Ga , Ex db ia IIC T6 ... T4 Gb , Ex db mb IIC T6 ... T4 Gb. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Outside installation |
| Installation in hazardous area | Zone 1 / Div. 1 |
Fieldbus connection
| Connection | 2-wire cable, red+, black- |
| Rated voltage | max. 32 V DC UN |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity
| Electromagnetic compatibility | NE 21:2011 |
| Degree of protection | IEC/EN 60529 |
| Fieldbus standard | IEC 61158-2 |
Ambient conditions
| Ambient temperature | -50 ... 85 °C (-58 ... 185 °F) |
| Storage temperature | -50 ... 85 °C (-58 ... 185 °F) |
Mechanical specifications
| Core cross section | 0.75 mm2 |
| Housing | 77 mm x 22 mm |
| Housing material | Stainless steel 1.4401/316 |
| Degree of protection | IP67 |
| Mass | 100 g |
| Mounting | 20 mm ISO thread PG13.5 thread 1/2 NPT thread |
Data for application in connection with hazardous areas
| EU-type examination certificate | DMT 01 ATEX 104 X |
| Marking II 1G Ex ia IIC T6 ... T4 Ga , [exsign] II 2G Ex db ia IIC T6 ... T4 Gb , [exsign] II 2G Ex db mb IIC T6 ... T4 Gb , max. permissible explosion (reference) pressure of the Ex d enclosure: 20 barTemperature classT6 for ambient temperature ≤ 60 °CT5 for ambient temperature ≤ 75 °CT4 for ambient temperature ≤ 85 °C | Marking |
| Marking | II 1G Ex ia IIC T6 ... T4 Ga , [exsign] II 2G Ex db ia IIC T6 ... T4 Gb , [exsign] II 2G Ex db mb IIC T6 ... T4 Gb , max. permissible explosion (reference) pressure of the Ex d enclosure: 20 bar |
| Temperature class | T6 for ambient temperature ≤ 60 °CT5 for ambient temperature ≤ 75 °CT4 for ambient temperature ≤ 85 °C |
| Maximum values | acc. to FISCO |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2012 , EN 60079-1:2014 , EN 60079-11:2012 , EN 60079-18:2015 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-1:2014 , EN 60079-11:2012 , EN 60079-18:2015 |
International approvals
| IECEx approval | IECEx BVS 10.0022X |
| Approved forEx ia IIC T6 ... T4 Ga , Ex db ia IIC T6 ... T4 Gb , Ex db mb IIC T6 ... T4 Gb | Approved for |
| Approved for | Ex ia IIC T6 ... T4 Ga , Ex db ia IIC T6 ... T4 Gb , Ex db mb IIC T6 ... T4 Gb |
General information
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G