IFM PQ3834
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PQ3834 be shipped?
PQ3834 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PQ3834 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PQ3834 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PQ3834, subject to availability and destination.
Reliable monitoring of the system pressure in pneumatics and in compressed air systems Very high overpressure and vacuum resistance Clearly visible slanted LED display Red/green display for clear identification of the acceptable range With programmable switching output and analogue output Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | -1...10 bar; -15...145 psi; -30...296 inHg; -100...1000 kPa |
| -1...10 bar | -15...145 psi |
| Process connection | threaded connection G 1/8 internal thread internal thread:M5 |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Conditionally suitable for | other media on request |
| Medium temperature[°C] [°C] | 0...60 |
| Min. burst pressure | 30 bar; 435 psi; 886 inHg; 3000 kPa |
| 30 bar | 435 psi |
| Note on min. burst pressure | max. overpressure on second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354,4 inHg / 1,2 MPa |
| Pressure rating | 20 bar; 290 psi; 591 inHg; 2000 kPa |
| 20 bar | 290 psi |
| Vacuum resistance | -1000 mbar; -0.1 MPa |
| -1000 mbar | -0.1 MPa |
| Type of pressure | relative pressure; differential pressure; vacuum |
Electrical data
| Operating voltage[V] [V] | 18...32 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 50 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Overvoltage protection | yes; (< 40 V) |
| Power-on delay time[s] [s] | 0.5 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | < 100 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
Measuring/setting range
| Measuring range | -1...10 bar; -15...145 psi; -30...296 inHg; -100...1000 kPa |
| -1...10 bar | -15...145 psi |
| Set point SP | -0.9...10 bar; -13...145 psi; -26...296 inHg; -90...1000 kPa |
| -0.9...10 bar | -13...145 psi |
| Reset point rP | -0.95...9.95 bar; -14...144 psi; -28...294 inHg; -95...995 kPa |
| -0.95...9.95 bar | -14...144 psi |
| In steps of | 0.05 bar; 1 psi; 2 inHg; 5 kPa |
| 0.05 bar | 1 psi |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,5 |
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,25 |
| Long-term stability[% of the span] [% of the span] | < ± 0,05; (per 6 months) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | 0,2; (0...60 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | 0,2; (0...60 °C) |
Response times
| Response time[ms] [ms] | < 6 |
| Delay time programmable dS, dr[s] [s] | 0; 0,002...5 |
| Step response time analogue output[ms] [ms] | 6 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; analogue output; IO-Link; switching logic; switch-on/switch-off delay; Damping; Display unit |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 FDIS |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Process data variable |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 2.3 |
| Supported DeviceIDs | default; 367 |
| default | 367 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...70 |
| Storage temperature[°C] [°C] | -25...85 |
| Protection | IP 65 |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 437 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 87 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 42 x 30 x 32 |
| Materials | PBT; FKM; polyester |
| Materials (wetted parts) | brass; FKM; silicon (coated); PBT |
| Min. pressure cycles | 50 million |
| Process connection | threaded connection G 1/8 internal thread internal thread:M5 |
Displays / operating elements
| Display | Display unit; 4 x LED, green; switching status; 1 x LED, yellow; function display; alphanumeric display, 4-digit; measured values; alphanumeric display, 4-digit |
| Display unit | bar; kPa; psi; inHg |
| switching status | 1 x LED, yellow |
| function display | alphanumeric display, 4-digit |
| measured values | alphanumeric display, 4-digit |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M8; coding: A; Contacts: gold-plated |