IFM M9H212
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | All magnetic sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can M9H212 be shipped?
M9H212 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up M9H212 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for M9H212 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for M9H212, subject to availability and destination.
Pressure-resistant up to 350 bar Designed for use in plunger detection Compact and robust stainless steel housing Spanner flat for easy mounting High shock and vibration resistance for mobile applications
Specifications
Product characteristics
| Electrical design | PNP |
| Output function | normally open |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 13.8 / L = 56.5 |
Application
| Application | lubricant distributor with plunger |
| Media | detects ferrous metals |
| Min. burst pressure[MPa] [MPa] | 200 |
| Pressure rating | 350 bar; 35 MPa |
| 350 bar | 35 MPa |
Electrical data
| Operating voltage[V] [V] | 10...60 DC |
| Rated insulation voltage[V] [V] | 60 |
| Current consumption[mA] [mA] | < 20 |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time[ms] [ms] | 300 |
Outputs
| Electrical design | PNP |
| Output function | normally open |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Max. leakage current[mA] [mA] | 0.1 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 50 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Detection zone
| Real sensing range Sr[mm] [mm] | 2 ± 10 % |
| Operating distance[mm] [mm] | 0...1.62 |
Accuracy / deviations
| Hysteresis[% of Sr] [% of Sr] | 3...15 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
| Note on ambient temperature | Operating voltage: <45V; for flexibly laid cable: -25 °C; for firmly laid cable: -40 °C |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m 80...2000 MHz; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V 0,15...80 MHz; EN 61000-4-8; 30 A/m; EN 55011; class B; noise emission and noise immunity according to the automotive directive 95/54/EC; E1 type approval; conducted interference in 24 V networks to ISO 7637-2: 2004 (pulse 1 to 4); pulse; 1 2a 2b 3a 3b 4; severity level; III III III III III III; failure criterion; C B C A A C |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m 80...2000 MHz |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V 0,15...80 MHz |
| EN 61000-4-8 | 30 A/m |
| EN 55011 | class B |
| noise emission and noise immunity according to the automotive directive 95/54/EC | E1 type approval |
| pulse | 1 2a 2b 3a 3b 4 |
| severity level | III III III III III III |
| failure criterion | C B C A A C |
| Vibration resistance | EN 60068-2-6 Fc; 50x 20 g / 10...3000 Hz -20 °C; EN 60068-2-6 Fc; 50x 20 g / 10...3000 Hz +50 °C |
| EN 60068-2-6 Fc | 50x 20 g / 10...3000 Hz +50 °C |
| Shock resistance | EN 60068-2-27 Ea; 3 x 100 g 11 ms / -25 °C; EN 60068-2-27 Ea; 3 x 100 g 11 ms / +85 °C |
| EN 60068-2-27 Ea | 4000 x 40 g 6 ms / -20 °C / 50 °C |
| Continuous shock resistance | EN 60068-2-27 Ea; 4000 x 40 g 6 ms / -20 °C / 50 °C |
| MTTF[years] [years] | 1181 |
Mechanical data
| Weight[g] [g] | 78.9 |
| Housing | cylindrical |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | Ø 13.8 / L = 56.5 |
| Materials | sensing face: stainless steel (316L/1.4404); housing: stainless steel (316L/1.4404); end cap: TPU |
| Tightening torque[Nm] [Nm] | < 18 |
| Process connection | threaded connection M11 x 1 external thread |
Displays / operating elements
| Display | switching status; LED, yellow |
| switching status | LED, yellow |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Cable | 0.5 m, PUR |
| Connector | 1 x M12; coding: A |