Quick facts

AvailabilityConfirmed on request
CategoryDigital mixed modules
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)
Weight350 kg

Shipping & availability

When can X67SC4122.L12 be shipped?

X67SC4122.L12 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X67SC4122.L12 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X67SC4122.L12 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X67SC4122.L12, subject to availability and destination.

• 8 safe digital inputs, sink circuit

• 8 pulse outputs

• Software input filter configurable for each channel

• 4 safe digital outputs, output type B with 2 A, source circuit

• Node number switches for setting the X2X Link address

• Integrated output protection

The module is equipped with 8 safe digital inputs and 4 safe digital outputs. They are designed for a nominal voltage of 24 VDC.

The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3.

The node number switch for setting the X2X Link address is a unique feature. When modular machine configurations change, it is necessary, for example, to define specific module groups at a fixed address that is independent of the preceding modules in the line. All subsequent standard modules refer to this offset and use it automatically for addressing purposes.

The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line.

The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur.

Specifications

Short description

I/O module8 safe type A digital inputs, 8 pulse outputs, 24 VDC, 4 safe type B1 digital outputs, 24 VDC, 2 A, OSSD <500 µs

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – OutputsYes, using LED status indicator and software
Diagnostics – InputsYes, using LED status indicator and software
Blackout mode – ScopeModule
Blackout mode – FunctionModule functionality
Blackout mode – Standalone modeNo
Connection type – X2X LinkM12, B-coded
Connection type – Inputs/OutputsM12, A-coded
Connection type – I/O power supplyM8, 4-pin
Power consumption – Bus0.8 W
Power consumption – Internal I/O1.8 W
Additional power dissipation caused by actuators (resistive) [W] " data-placement="top" data-html="true" data-container="body" data-content="Number of outputs x R<sub>DS(on)</sub> x Nominal output current<sup>2</sup>. This value also applies to sensors that are supplied via these outputs. For a calculation example, see section "Mechanical and electrical configuration" in the X20 system user's manual."> – Safe digital outputs2.25
Additional power dissipation caused by actuators (resistive) [W] " data-placement="top" data-html="true" data-container="body" data-content="Number of outputs x R<sub>DS(on)</sub> x Nominal output current<sup>2</sup>. This value also applies to sensors that are supplied via these outputs. For a calculation example, see section "Mechanical and electrical configuration" in the X20 system user's manual."> – Pulse outputs0.08
Electrical isolation – Channel - BusYes
Electrical isolation – Channel - ChannelNo
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – Functional safetycULus FSPC E361559; Energy and industrial systems; Certified for functional safety; ANSI UL 1998:2013
Certifications – Functional safetyIEC 61508, up to SIL 3 ; IEC 62061, up to SIL 3 ; ISO 13849-1, up to Cat. 4 / PL e ; IEC 61511, up to SIL 3
Certifications – Functional safetyEN 50156-1
Certifications – ATEXZone 2, II 3G Ex nA IIA T5 Gc; IP67, Ta = 0 - Max. 60°C; TÜV 05 ATEX 7201X
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – KCYes
B&R ID code0xA7A6
Status indicatorsI/O function per channel, operating state, module status

Safety characteristics

NoteSee section "Safety characteristics".

I/O power supply

Nominal voltage24 VDC
Voltage range18 to 30 VDC
Integrated protective functionReverse polarity protection

Safe digital inputs

Input filter – Hardware≤150 μs
Input filter – SoftwareConfigurable between 0 and 500 ms
Switching threshold – Low<5 VDC
Switching threshold – High>15 VDC
Quantity8
VariantType A
Nominal voltage24 VDC
Input characteristics per EN 61131-2Type 1
Input circuitSink
Input voltage24 VDC -15% / +20%
Input current at 24 VDC " data-placement="top" data-html="true" data-container="body" data-content="The input current specifications refer to the switched-on state of the input.">Min. 2 mA to max. 4.59 mA
Input resistanceMin. 5.23 kΩ
Error detection time200 ms
Insulation voltage between channel and bus500 V eff
Line length between signal source (pulse output or external signal) and inputMax. 60 m with unshielded line; Max. 400 m with shielded line

Safe digital outputs

Quantity4
VariantFET, 2x positive switching, type B1, output level readable
Nominal voltage24 VDC
Nominal output current2 A
Total nominal current5 A
Output protectionSee section "Inrush current behavior for output channels".
Braking voltage when switching off inductive loadsMax. 45 VDC
Error detection time1 s
Insulation voltage between channel and bus500 V eff
Peak short-circuit currentSee section "Inrush current behavior for output channels".
Leakage current when the output is switched off100 μA
R DS(on)250 mΩ
Switching voltageI/O power supply minus voltage drop due to R DS(on)
Max. switching frequencySee section "Inrush current behavior for output channels".
Test pulse lengthMax. 1 ms
Max. capacitive load100 nF
Peak output current2.5 A (effective current ≤2 A)
Minimum load12 mA, hardware revision I0 and later: 0 mA

Current on loss of ground

I OUT<3 mA, hardware revision B2 and later: <1 mA, hardware revision I0 and later: <100 μA
I GND<110 mA

Pulse outputs

Quantity8
VariantPush-Pull
Nominal output current50 mA
Output protectionShutdown of individual channels in the event of overload or short circuit " data-placement="top" data-html="true" data-container="body" data-content="The protective function is provided for max. 30 minutes for a continuous short circuit.">
Peak short-circuit current25 A for 5 ms
Short-circuit current1.4 A eff
Leakage current when the output is switched off0.1 mA
R DS(on)4 Ω
Switching voltageI/O power supply minus voltage drop due to R DS(on)
Total nominal current400 mA

Operating conditions

Mounting orientation – AnyYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP67

Ambient conditions

Temperature – Operation-40 to 60°C " data-placement="top" data-html="true" data-container="body" data-content="Up to hardware revision &lt;D0: 0 to 60&#xB0;C">
Temperature – Storage-40 to 85°C
Temperature – Transport-40 to 85°C

Mechanical properties

Dimensions – Width53 mm
Dimensions – Height155 mm
Dimensions – Depth42 mm
Torque for connections – M8Max. 0.4 Nm
Torque for connections – M12Max. 0.6 Nm
Weight350 g

Downloads & documentation

Official documents from B&R, downloaded directly from the manufacturer.

Data sheets & manuals

Data sheets SafeIO and SafeLogicPDF · 28 MB · 3.5.0 (09/02/2026) - EN
Integrated safety technology user's manualPDF · 46 MB · 6.8.0 (09/02/2026) - EN
X67 System User´s ManualPDF · 21 MB · 4.40 (08/27/2026) - EN

CAD & dimension drawings

3D file DFX/STEP X674122.L12ZIP · 2 MB · 1.00 (11/14/2014)
Certificates (11)
2226379 CSA Certificate of Compliance X20 X67PDF · 205 KB · 2026_09 (09/21/2026)
E115267 UL CoC X67PDF · 345 KB · 2026_01 (01/29/2026)
EU Data Act - X20-X67 SafeIO - Connected Product Information NoticePDF · 93 KB · 1.0 (10/02/2025)
EU Declaration FS PLC X67PDF · 230 KB · 2019/07 (09/23/2019)
FS EN 50156 Zertifikat SafeLOGIC, SafeIOPDF · 314 KB · 1.100 (11/20/2017)
M6A 041745 0010 TÜV Süd FS Certificate SafeDESIGNER, SafeLOGIC, SafeIOPDF · 2 MB · 1.10.46 (09/09/2026)
M6A 041745 0013 TÜV Süd FS Certificate mapp SafetyPDF · 2 MB · 6.4.3 / 1.40 (09/01/2026)
M6A 041745 0023 TÜV Süd FS Certificate Safety+PDF · 3 MB · 6.8.0 / 1.6 (09/02/2026)
TÜV 05 ATEX 7201 XPDF · 5 MB · 1.10 (03/24/2021)
UK Declaration FS PLC X67PDF · 112 KB · 2022-07 (09/01/2022)
X20, X67 KC certificatesPDF · 7 MB · 2.00 (08/17/2026)
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More B&R parts

B&R X67HB8880.L12 – Hub, 8-port industrial hubAvailable on requestB&R X67HB8880.L12 – Hub, 8-port industrial hub
MPN: X67HB8880.L12 · B&R
Price on request
Request a quote
B&R X67IF1121-1 – Communication module, 1x RS232 or 1x RS485/RS422Available on requestB&R X67IF1121-1 – Communication module, 1x RS232 or 1x RS485/RS422
MPN: X67IF1121-1 · B&R
Price on request
Request a quote
B&R X67MM2436 – I/O module, 2-channel PWM output (H bridge)Available on requestB&R X67MM2436 – I/O module, 2-channel PWM output (H bridge)
MPN: X67MM2436 · B&R
Price on request
Request a quote
B&R X67PS1300 – System power supply modulesAvailable on requestB&R X67PS1300 – System power supply modules
MPN: X67PS1300 · B&R
Price on request
Request a quote