Multilevel installation terminal block; with operating slots; 2.5 mm²; with N-disconnect slide link; LT/L; Push-in CAGE CLAMP®; 2,50 mm²; gray
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Rail-Mount Terminal Blocks |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 2003-7659 be shipped?
2003-7659 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 2003-7659 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 2003-7659 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 2003-7659, subject to availability and destination.
<h2>Multilevel installation terminal block, 2003 Series, gray</h2><br/><br/>This multilevel installation terminal block (item number 2003-7659) is designed for simple and secure connections. Conductors should only be connected to this multilevel installation terminal block if their strip length is between 10 and 12 mm . This product incorporates conductor terminals and utilizes Push-in CAGE CLAMP®. Push-in CAGE CLAMP® technology provides a universal connection solution for all conductor types. It allows both solid and fine-stranded conductors with ferrules to be inserted directly into the clamping point without the need for tools. Depending on the conductor type, this multilevel installation terminal block is designed for conductor cross sections ranging from 0.25 mm² to 4 mm².<br/><br/><h3></h3>
Specifications
Electrical data - Ratings per IEC/EN
| Ratings | Potential – ground |
| Ratings per | IEC/EN 60947-7-1 |
| Nominal voltage (III/3) | 250 V |
| Rated impulse withstand voltage (III / 3) | 4 kV |
| Rated current | 24 A |
| Current at conductor cross-section (max.) mm² | 32 A |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings | Potential - ground / Potential - ground / Potential - ground |
| Ratings per | IEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 250 V |
| Rated impulse withstand voltage | 4 kV |
| Rated current | 24 A |
| Current at conductor cross-section (max.) mm² | 32 A |
Electrical data - Ratings per IEC/EN 2
| Ratings | Potential – potential |
| Ratings per | IEC/EN 60947-7-1 |
| Rated voltage (III / 3) | 400 V |
| Rated impulse withstand voltage (III/3) | 6 kV |
| Rated current | 24 A |
| Current at conductor cross-section (max.) | 32 A |
| Ratings | Potential - potential / Potential - potential / Potential - potential |
| Ratings per | IEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 400 V |
| Rated impulse withstand voltage | 6 kV |
| Rated current | 24 A |
| Current at conductor cross-section (max.) mm² | 32 A |
Electrical data - Power Loss
| Power loss, per pole (potential) | 0.766 W |
| Rated current I<sub>N</sub> for power loss specification | 24 A |
| Resistance value for specified, current-dependent power loss | 0.001 Ω |
Electrical data - General information
| Wiring direction | Front-entry wiring |
Connection data
| Clamping units | 3 |
| Total number of potentials | 2 |
| Number of levels | 3 |
Connection data - Connection 1
| Connection technology | Push-in CAGE CLAMP® |
| Actuation type | Operating tool |
| Connectable conductor materials | Copper |
| Nominal cross-section | 2.5 mm² |
| Solid conductor | 0.25 … 4 mm² / 22 … 12 AWG |
| Solid conductor; push-in termination | 0.75 … 4 mm² / 18 … 12 AWG |
| Fine-stranded conductor | 0.25 … 4 mm² / 22 … 12 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.25 … 2.5 mm² / 22 … 14 AWG |
| Fine-stranded conductor; with ferrule; push-in termination | 1 … 2.5 mm² / 18 … 14 AWG |
| Note (conductor cross-section) | Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination. |
| Strip length | 10 … 12 mm / 0.39 … 0.47 inches |
| Wiring direction | Front-entry wiring |
Physical data
| Width | 5.2 mm / 0.205 inches |
| Height | 96 mm / 3.78 inches |
| Depth from upper-edge of DIN-rail | 42.3 mm / 1.665 inches |
Mechanical data
| Potential marking | LT/L |
| Mounting type | DIN-35 rail |
| Marking level | Center/side marking |
Material data
| Note (material data) | Information on material specifications can be found here |
| Color | gray |
| Material group | I |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Fire load | 0.245 MJ |
| Weight | 13.9 g |
Environmental requirements
| Processing temperature | -35 … +85 °C |
| Continuous operating temperature | -60 … +105 °C |
Commercial data
| Product Group | 22 (TOPJOB S) |
| PU (SPU) | 50 pcs |
| Packaging type | box |
| Country of origin | DE |
| GTIN | 4045454792749 |
| Customs tariff number | 85369010000 |
Product Classification
| UNSPSC | 39121410 |
| eCl@ss 10.0 | 27-14-11-25 |
| eCl@ss 9.0 | 27-14-11-25 |
| ETIM 9.0 | EC001329 |
| ETIM 10.0 | EC001329 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |