Quick facts
| Availability | Confirmed on request |
| Category | PBT |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PBT-RB040AU1SEFALA0Z be shipped?
PBT-RB040AU1SEFALA0Z is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PBT-RB040AU1SEFALA0Z in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PBT-RB040AU1SEFALA0Z and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PBT-RB040AU1SEFALA0Z, subject to availability and destination.
Pressure sensors | PBT | PBT-RB040AU1SEFALA0Z | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 40 bar | Accuracy: ≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) | Process connection: 7/16" –20 UNF (SAE J514) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: FKM | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: L-connector (DIN EN 175301-803 A), IP65 | Supply voltage: 8 V DC ... 30 V DC
Specifications
Features
| Medium | Liquid, gaseous |
| Pressure type | Gauge pressure |
| Pressure unit | bar |
| Measuring range | 0 bar ... 40 bar |
| Process temperature | â30 °C ... +100 °C |
| Maximum ohmic load RA | 4 mA ... 20 mA, 2-wire (RA ⤠(L+ - 8 V) / 0.02 A [Ohm]), 0 V ... 10 V, 3-wire (RA > 10 kOhm), 0 V ... 5 V, 3-wire (RA > 5 kOhm) |
| Output signal | 4Â mAÂ ... 20Â mA, 2-wire |
Mechanics/electronics
| Communication interface | - |
| Process connection | 7/16" â20 UNF (SAE J514)Â 1) |
| Wetted parts | Process connection: 316L stainless steelMeasuring chamber: stainless steel 316L |
| Internal transmission fluid | Silicone oil (only with pressure ranges < 0 bar ... 10 bar and ⤠0 bar abs ... 25 bar abs) |
| Pressure port | Standard |
| Housing material | Stainless steel |
| Connection type | L-connector (DINÂ ENÂ 175301-803 A) |
| Supply voltage | 8Â VÂ DCÂ ... 30Â VÂ DCÂ 2) |
| Power consumption | Signal current (max. 25Â mA) for current outputMax. 8Â mA for voltage output signal |
| Electrical safety | Overvoltage protection: 32Â VÂ DC, 36Â VÂ DC with 4Â mAÂ ... 20Â mAShort-circuit protection: QA towards MReverse polarity protection: L+ to MProtection class: III |
| Isolation voltage | 500Â VÂ DC |
| CE-conformity | Pressure equipment directive: 2014/68/EU, EMC directive: 2014/30/EU, ENÂ 61 326-2-3 |
| Weight sensor | Approx. 80 g |
| Seal | FKM |
| Enclosure rating | IP65Â 3) |
| Protection class III | â |
| MTTF | 815Â years |
| Pressure peak dampening | Through integrated pressure port 0.6 mm or 0.3 mm for process connection G ¼ according to DIN 3852-E (0.3 mm at and above 10 bar) |
| Overvoltage protection | 36Â VÂ DC |
Performance
| Non-linearity | ⤠± 0.25 %, (Best Fit Straight Line, BFSL) according to IEC 61298-2 |
| Accuracy | ⤠± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2)) |
| Adjustment accuracy of zero signal | ⤠0.15 % of span typ., ⤠0.4 % of span max. (with non-linerarity 0.25 %) |
| Hysteresis | â¤Â 0.16 % of the span |
| Non-repeatability | â¤Â 0.1 % of the span |
| Response time | <Â 4Â ms |
| Signal noise | â¤Â 0.3 % of the span |
| Long-term drift/one-year stability | â¤Â 0.1 % of span to IEC 61298-2 |
| Rated temperature range | 0 °C ... +80 °C |
| Service life | Minimum 100Â Mio. load cycles |
| Temperature error | ⤠± 1.0% of the range, typ., ⤠± 2.5% of the range max. |
| Reference conditions | Reference conditions: According to IECÂ 61298-1 |
Ambient data
| Ambient temperature, operation | 0 °C ... +80 °C |
| Storage temperature | â40 °C ... +70 °C |
| Relative humidity | 45Â %Â ... 75Â % |
| Shock load | 500Â g according to IECÂ 60068-2-27 (mechanical shock) |
| Vibration load | 10Â g according to IECÂ 60068-2-6 (vibration under resonance)20Â g optional |
Certificates
| EU declaration of conformity | â |
| UK declaration of conformity | â |
| China RoHS | â |
| cULus certificate | â |
Classifications
| ECLASS 5.0 | 27200614 |
| ECLASS 5.1.4 | 27200614 |
| ECLASS 6.0 | 27200614 |
| ECLASS 6.2 | 27200614 |
| ECLASS 7.0 | 27200614 |
| ECLASS 8.0 | 27200614 |
| ECLASS 8.1 | 27200614 |
| ECLASS 9.0 | 27200614 |
| ECLASS 10.0 | 27200614 |
| ECLASS 11.0 | 27200614 |
| ECLASS 12.0 | 27200614 |
| ETIM 5.0 | EC011478 |
| ETIM 6.0 | EC011478 |
| ETIM 7.0 | EC011478 |
| ETIM 8.0 | EC011478 |
| UNSPSC 16.0901 | 41112410 |