Pepperl Fuchs FB7204B3

MPN: FB7204B3 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryFB (Zone 1)
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FB7204B3 be shipped?

FB7204B3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FB7204B3 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FB7204B3 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FB7204B3, subject to availability and destination.

Universal Input/Output (HART). 4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication. Occupied slots: 1. Connection: backplane bus. Rated voltage: 12 V DC , only in connection with the power supplies FB92**. Power dissipation: 2 W. Power consumption: 3 W. Connection: backplane bus. Interface: manufacturer-specific bus to standard com unit. Number of channels: 4. Suitable field devices: . Field devicepressure converterField device [2]flow converterField device [3]level converterField device [4]Temperature Converter: . Field device: pressure converter. Field device [2]: flow converter. Field device [3]: level converter. Field device [4]: Temperature Converter. Field device interface: . Connection2-wire transmitter: . Connection: 2-wire transmitter. Connection: terminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-. Transmitter supply voltage: min. 15 V at 20 mA ; 21.5 V at 4 mA. Input resistance: 15 Ω. Line fault detection: can be switched on/off for each channel via configuration tool , configurable via configuration tool. Short-circuitfactory setting: > 21 mA Can be parameterized in the range 0 ... 22 mAOpen-circuitfactory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA: . Short-circuit: factory setting: > 21 mA Can be parameterized in the range 0 ... 22 mA. Open-circuit: factory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA. HART communication: yes. HART secondary variable: yes. Number of channels: 4. Suitable field devices: . Field deviceProportional ValveField device [2]I/P convertersField device [3]on-site display: . Field device: Proportional Valve. Field device [2]: I/P converters. Field device [3]: on-site display. Connection: terminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-. Current: 0 ... 20 mA short-circuit protected. Line fault detection: can be switched on/off for each channel via configuration tool , configurable via configuration tool. Short-circuitfactory setting: < 50 Ω configurable between 0 ... 26 mAOpen-circuitdeviation of preset output value > 0.5 mA: . Short-circuit: factory setting: < 50 Ω configurable between 0 ... 26 mA. Open-circuit: deviation of preset output value > 0.5 mA. Load: max. 750 Ω at 20 mA. HART communication: yes. HART secondary variable: yes. Watchdog: output off 0.5 s after serious fault. Number of channels: 4. Sensor interface: . Connection [2]volt-free contact: . Connection [2]: volt-free contact. Connection: terminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-. Line fault detection: can be switched on/off for each channel via configuration tool. Connectionmechanical switch with additional resistors (see connection diagram)Short-circuit> 7 mAOpen-circuit< 0.1 mA: . Connection: mechanical switch with additional resistors (see connection diagram). Short-circuit: > 7 mA. Open-circuit: < 0.1 mA. Digital signals (active): . Switching point: ON> 2.1 mASwitching point: OFF< 1.2 mA: . Switching point: ON: > 2.1 mA. Switching point: OFF: < 1.2 mA. Number of channels: 4. Suitable field devices: . Field deviceSolenoid ValveField device [2]audible alarmField device [3]visual alarm: . Field device: Solenoid Valve. Field device [2]: audible alarm. Field device [3]: visual alarm. Connection: terminals 1+, 2-, 3+, 4-, 5+, 6-, 7+, 8-. Drive capability: 12 V / 22 mA. Internal resistor: 385 Ω. Current limit: 22 mA. Open loop voltage: min. 22.7 V. Line fault detection: can be switched on/off for each channel via configuration tool. Test current0.4 mAShort-circuit< 50 ΩOpen-circuit< 0.2 mA: . Test current: 0.4 mA. Short-circuit: < 50 Ω. Open-circuit: < 0.2 mA. Deviation: . After calibration0.1 % of the signal range at 20 °C (68 °F)Influence of ambient temperature0.1 %/10 K of the signal range: . After calibration: 0.1 % of the signal range at 20 °C (68 °F). Influence of ambient temperature: 0.1 %/10 K of the signal range. Resolution: 12 Bit (0 ... 26 mA). Refresh time: approx. 100 ms (4 channels). LED indication: Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Configuration LED (AI, AO, DI, DO) white: selected channel mode. Coding: optional mechanical coding via front socket. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Environmental test: EN 60068-2-14. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Damaging gas: EN 60068-2-42. Relative humidity: EN 60068-2-78. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 95 % non-condensing. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , a separate housing is required acc. to the system description. Connection: removable front connector with screw flange (accessory)wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2). Mass: approx. 425 g. Dimensions: . Height107 mmWidth28 mmDepth132 mm: . Height: 107 mm. Width: 28 mm. Depth: 132 mm. EU-type examination certificate: Presafe 19 ATEX 14057U. Marking II 2(1)G Ex db eb q [ia Ga] IIC Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I: . Marking: II 2(1)G Ex db eb q [ia Ga] IIC Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I. Supply: . VoltageUo27 VCurrentIo87 mAPowerPo575 mW (linear characteristic): Uo. Voltage: 27 V. Current: 87 mA. Power: 575 mW (linear characteristic). Output: Ex ia. VoltageUo27 VCurrentIo87 mAPowerPo575 mW (linear characteristic)Internal capacitanceCi12 nFInternal inductanceLi0 mH: Uo. Voltage: 27 V. Current: 87 mA. Power: 575 mW (linear characteristic). Internal capacitance: 12 nF. Internal inductance: 0 mH. Galvanic isolation: . Rated voltageUm250 V field circuits to control and supply circuitsInput/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 VOutput/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V: Um. Rated voltage: 250 V field circuits to control and supply circuits. Input/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V. Output/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012. ATEX approval: Presafe 19 ATEX 14057U. IECEx approval: . IECEx certificateIECEx PRE 19.0012UIECEx markingEx db eb q [ia Ga] IIC Gb [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx PRE 19.0012U. IECEx marking: Ex db eb q [ia Ga] IIC Gb [Ex ia Da] IIIC [Ex ia Ma] I. System information: The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Specifications

Slots

Occupied slots1

Supply

Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies FB92** Ur
Power dissipation2 W
Power consumption3 W

Internal bus

Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit

Analog input

Number of channels4
Suitable field devices
Field devicepressure converterField device [2]flow converterField device [3]level converterField device [4]Temperature Converter Field device
Field devicepressure converter
Field device [2]flow converter
Field device [3]level converter
Field device [4]Temperature Converter
Field device interface
Connection2-wire transmitter Connection
Connection2-wire transmitter
Connectionterminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-
Transmitter supply voltagemin. 15 V at 20 mA ; 21.5 V at 4 mA
Input resistance15 Ω
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
Short-circuitfactory setting: > 21 mA Can be parameterized in the range 0 ... 22 mAOpen-circuitfactory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA Short-circuit
Short-circuitfactory setting: > 21 mA Can be parameterized in the range 0 ... 22 mA
Open-circuitfactory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA
HART communicationyes
HART secondary variableyes

Analog output

Number of channels4
Suitable field devices
Field deviceProportional ValveField device [2]I/P convertersField device [3]on-site display Field device
Field deviceProportional Valve
Field device [2]I/P converters
Field device [3]on-site display
Connectionterminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-
Current0 ... 20 mA short-circuit protected
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
Short-circuitfactory setting: < 50 Ω configurable between 0 ... 26 mAOpen-circuitdeviation of preset output value > 0.5 mA Short-circuit
Short-circuitfactory setting: < 50 Ω configurable between 0 ... 26 mA
Open-circuitdeviation of preset output value > 0.5 mA
Loadmax. 750 Ω at 20 mA
HART communicationyes
HART secondary variableyes
Watchdogoutput off 0.5 s after serious fault

Digital input

Number of channels4
Sensor interface
Connection [2]volt-free contact Connection [2]
Connection [2]volt-free contact
Connectionterminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8-
Line fault detectioncan be switched on/off for each channel via configuration tool
Connectionmechanical switch with additional resistors (see connection diagram)Short-circuit> 7 mAOpen-circuit< 0.1 mA Connection
Connectionmechanical switch with additional resistors (see connection diagram)
Short-circuit> 7 mA
Open-circuit< 0.1 mA
Digital signals (active)
Switching point: ON> 2.1 mASwitching point: OFF< 1.2 mA Switching point: ON
Switching point: ON> 2.1 mA
Switching point: OFF< 1.2 mA

Digital output

Number of channels4
Suitable field devices
Field deviceSolenoid ValveField device [2]audible alarmField device [3]visual alarm Field device
Field deviceSolenoid Valve
Field device [2]audible alarm
Field device [3]visual alarm
Connectionterminals 1+, 2-, 3+, 4-, 5+, 6-, 7+, 8-
Drive capability12 V / 22 mA
Internal resistor385 Ω Ri
Current limit22 mA Imax
Open loop voltagemin. 22.7 V Us
Line fault detectioncan be switched on/off for each channel via configuration tool
Test current0.4 mAShort-circuit< 50 ΩOpen-circuit< 0.2 mA Test current
Test current0.4 mA
Short-circuit< 50 Ω
Open-circuit< 0.2 mA

Transfer characteristics

Deviation
After calibration0.1 % of the signal range at 20 °C (68 °F)Influence of ambient temperature0.1 %/10 K of the signal range After calibration
After calibration0.1 % of the signal range at 20 °C (68 °F)
Influence of ambient temperature0.1 %/10 K of the signal range
Resolution12 Bit (0 ... 26 mA)
Refresh timeapprox. 100 ms (4 channels)

Indicators/settings

LED indicationPower LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Configuration LED (AI, AO, DI, DO) white: selected channel mode
Codingoptional mechanical coding via front socket

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013

Conformity

Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Environmental testEN 60068-2-14
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Damaging gasEN 60068-2-42
Relative humidityEN 60068-2-78

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Connectionremovable front connector with screw flange (accessory)wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Massapprox. 425 g
Dimensions
Height107 mmWidth28 mmDepth132 mm Height
Height107 mm
Width28 mm
Depth132 mm

Data for application in connection with hazardous areas

EU-type examination certificatePresafe 19 ATEX 14057U
Marking II 2(1)G Ex db eb q [ia Ga] IIC Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I Marking
MarkingII 2(1)G Ex db eb q [ia Ga] IIC Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I
Supply
VoltageUo27 VCurrentIo87 mAPowerPo575 mW (linear characteristic)Uo Voltage
Voltage27 V Uo
Current87 mA Io
Power575 mW (linear characteristic) Po
OutputEx ia
VoltageUo27 VCurrentIo87 mAPowerPo575 mW (linear characteristic)Internal capacitanceCi12 nFInternal inductanceLi0 mHUo Voltage
Voltage27 V Uo
Current87 mA Io
Power575 mW (linear characteristic) Po
Internal capacitance12 nF Ci
Internal inductance0 mH Li
Galvanic isolation
Rated voltageUm250 V field circuits to control and supply circuitsInput/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 VOutput/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 VUm Rated voltage
Rated voltage250 V field circuits to control and supply circuits Um
Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012 Directive 2014/34/EU
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012

International approvals

ATEX approvalPresafe 19 ATEX 14057U
IECEx approval
IECEx certificateIECEx PRE 19.0012UIECEx markingEx db eb q [ia Ga] IIC Gb [Ex ia Da] IIIC [Ex ia Ma] I IECEx certificate
IECEx certificateIECEx PRE 19.0012U
IECEx markingEx db eb q [ia Ga] IIC Gb [Ex ia Da] IIIC [Ex ia Ma] I

General information

System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNew open boxPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote