IFM VVB001
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Vibration sensors and transmitters |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VVB001 be shipped?
VVB001 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VVB001 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VVB001 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VVB001, subject to availability and destination.
Condition-based maintenance thanks to monitoring of unbalance, rolling element bearing or gear state Large operating temperature range and high protection rating for the requirements of harsh industrial environments Reliable and permanent monitoring of characteristic values incl. raw data acquisition Integration in Industrial Ethernet systems without control cabinet and complex wiring Asynchronous transmission of raw data (BLOB) and integrated operating hours counter User-friendly communication and parameterisation via IO-Link Loss-free signal transmission of measurement values
Specifications
Product characteristics
| Frequency range[Hz] [Hz] | 2...10000 |
| Measuring principle | capacitive |
| Measuring range of vibration[mm/s] [mm/s] | 0...45 |
| Measuring range of vibration | 0...50 g; 0...490.3 m/s² |
| 0...50 g | 0...490.3 m/s² |
Application
| Application | industrial machines |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
| Current consumption[mA] [mA] | < 50 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Sensor type | microelectromechanical system (MEMS) |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
| Output signal | switching signal; IO-Link |
| Electrical design | PNP/NPN; (configurable) |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Max. current load per output[mA] [mA] | 100 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Note on setpoint SP | parameterisable |
| Frequency range[Hz] [Hz] | 2...10000 |
| Measuring principle | capacitive |
| Number of measurement axes | 1 |
| Measuring range of vibration[mm/s] [mm/s] | 0...45 |
| Set point SP[mm/s] [mm/s] | 0.2...45 |
| Reset point rP[mm/s] [mm/s] | 0...44.8 |
| In steps of[mm/s] [mm/s] | 0.2 |
| Measuring range of vibration | 1...50 |
| 0...50 g | 0...490.3 m/s² |
| Set point SP | 2...50 |
| 0.2...50 g | 2...490.3 m/s² |
| Reset point rP | 1...49 |
| 0...49.8 g | 0...488.3 m/s² |
| In steps of | 1 |
| 0.2 g | 2 m/s² |
| Measuring range[°C] [°C] | -30...80 |
| Resolution[°C] [°C] | 0.1 |
| Set point SP[°C] [°C] | -28...80 |
| Reset point rP[°C] [°C] | -30...78 |
| In steps of[°C] [°C] | 2 |
Accuracy / deviations
| Accuracy | ≤ 4 kHz +/-10 %; ≥ 4...10 kHz: < 3 dB |
| Accuracy[K] [K] | ± 2,5 K + (0,2 x (Umgebungstemperatur - Oberflächentemperatur)) |
| Linearity deviation | 2 % |
Software / programming
| Parameter setting options | Software |
| Diagnostic functions | self-test |
Interfaces
| Communication interface | IO-Link |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9: 2013-07 |
| Profiles | BLOB; Binary Large Object transfer; Common - I&D; Identification and Diagnosis; Function; Measurement data, standard resolution |
| BLOB | Binary Large Object transfer |
| Common - I&D | Identification and Diagnosis |
| Function | Measurement data, standard resolution |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 10 |
| Process data binary | 2 |
| IO-Link functions (acyclical) | filter for v-RMS, a-RMS, a-Peak; Hysteresis; window; switch points; switching logic |
| Supported DeviceIDs | Status A (COM2); 1028; Status B (COM2 / COM3); 1367 |
| Status A (COM2) | 1028 |
| Status B (COM2 / COM3) | 1367 |
| Note | For further information please see the IODD PDF file under "Downloads" |
| Transmission type | COM3 (230,4 kBaud) |
| Min. process cycle time[ms] [ms] | 3.6 |
Operating conditions
| Ambient temperature[°C] [°C] | -30...80 |
| Storage temperature[°C] [°C] | -30...80 |
| Protection | IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | 2014/30/EU; DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27; 50 g 11 ms; 500 g 1 ms |
| DIN EN 60068-2-27 | 50 g 11 ms |
| Vibration resistance | DIN EN 60068-2-6; 20 g / 10...3000 Hz |
| DIN EN 60068-2-6 | 20 g / 10...3000 Hz |
| MTTF[years] [years] | 299 |
| UL approval | Ta; -30...70 °C; UL approval no.; L002 |
| Ta | -30...70 °C |
| UL approval no. | L002 |
Mechanical data
| Weight[g] [g] | 116 |
| Housing | cylindrical |
| Type of mounting | set screw |
| Dimensions[mm] [mm] | Ø 22 / L = 63.55 |
| Materials | housing: stainless steel (316L/1.4404) |
| Tightening torque[Nm] [Nm] | 8 |
Accessories
| Items supplied | set screw: 1 x (1/4" 28 UNF / M8); set screw: 1 x (1/4"28 UNF x 5/8" DIN916) |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Maximum cable length: 20 m |