Quick facts
| Availability | Confirmed on request |
| Category | All ultrasonic sensors |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can UIT300 be shipped?
UIT300 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up UIT300 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for UIT300 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for UIT300, subject to availability and destination.
Continuous level and object detection for harsh environments Resistant to aggressive media Long range User-friendly communication and parameterisation via IO-Link Programmable switching output with IO-Link
Specifications
Product characteristics
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Sensing range[mm] [mm] | 250...2500; (Target: 400 x 400 mm) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 103 |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
| Current consumption[mA] [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 0.5 |
| Converter frequency[kHz] [kHz] | 112 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Electrical design | PNP/NPN; (parameterisable) |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.2 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 1 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Sensing range[mm] [mm] | 250...2500; (Target: 400 x 400 mm) |
| Blind zone[mm] [mm] | 250 |
| Angle of aperture cylindrical[°] [°] | 12; (±2) |
| Max. deviation from the 90° angle sensor/object[°] [°] | ± 4 |
Accuracy / deviations
| Temperature compensation | yes |
| Hysteresis[%] [%] | < 3 |
| Temperature drift | ± 5 %; (of the final value of the measuring range) |
| Repeatability | 1 % |
| Resolution[mm] [mm] | 3 |
| Notes on the accuracy / deviation | The indicated values are reached after a warm-up time of min. 20 minutes |
Software / programming
| Parameter setting options | hysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 3.1; Measuring Sensor; Common - I&D; Identification and Diagnosis; Function; Multiple switching signal; Function; Teach channel |
| Smart Sensor - SSP 3.1 | Measuring Sensor |
| Common - I&D | Identification and Diagnosis |
| Function | Teach channel |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 3.2 |
| IO-Link process data (cyclical) | process value; 16; device status; 4; binary switching information; 2 |
| process value | 16 |
| device status | 4 |
| binary switching information | 2 |
| IO-Link functions (acyclical) | application specific tag; operating hours counter |
| Supported DeviceIDs | default; 1388 |
| default | 1388 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | -10...60 |
| Storage temperature[°C] [°C] | -15...65 |
| Protection | IP 65; IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 3 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 3 V; EN 55011; Class A |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 3 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 3 V |
| EN 55011 | Class A |
| Vibration resistance | EN 60068-2-6 Fc; (10-55) Hz 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz |
| EN 60068-2-6 Fc | (10-55) Hz 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz |
| Shock resistance | EN 60068-2-27 Ea; 30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| MTTF[years] [years] | 108 |
Mechanical data
| Weight[g] [g] | 257.1 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 103 |
| Thread designation | M30 x 1.5 |
| Materials | stainless steel (316L/1.4404); LED window: TPU; potting: PUR |
| Tightening torque[Nm] [Nm] | 100 |
Displays / operating elements
| Display | switching status; 1 LED, yellow |
| switching status | 1 LED, yellow |
Accessories
| Items supplied | lock nuts: 2 x M30, stainless steel; damping plates: 2, EPDM |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x M12; coding: A |