IFM TAD081
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can TAD081 be shipped?
TAD081 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up TAD081 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for TAD081 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for TAD081, subject to availability and destination.
Hygienic design for the requirements of the food and beverage industry Precise scalable analogue output and high precision over the whole temperature range With diagnostic output for drift and fault monitoring High process safety due to self-monitoring Including free 5-point calibration certificate. User-friendly communication and parameterisation via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | -25...160 °C; -13...320 °F |
| -25...160 °C | -13...320 °F |
| Communication interface | IO-Link |
| Process connection | threaded connection G 1 external thread Aseptoflex Vario |
| Installation length EL[mm] [mm] | 50 |
Application
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 1000 + 1 x NTC; (thermically coupled, with backup function (temperature measuring even if one element fails)) |
| Media | liquids and gases |
| Pressure rating | 50 bar; 5 MPa |
| 50 bar | 5 MPa |
| Minimum installation depth[mm] [mm] | 25 |
| MAWP for applications according to CRN[bar] [bar] | 50 |
Electrical data
| Operating voltage[V] [V] | 18...32 DC; ("supply class 2" to cULus) |
| Current consumption[mA] [mA] | 6; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 8 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed / diagnostic signal; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 150; (200 (...60°C); 250 (...40 °C)) |
| Diagnostic output | Drift monitoring; fault monitoring |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | (Ub - 15 V) x 50 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Probe length L[mm] [mm] | 50 |
| Measuring range | -25...160 °C; -13...320 °F |
| -25...160 °C | -13...320 °F |
| Note on measuring range | scalable |
| Factory setting | 0...150 °C / 32...302 °F |
| Drift warning | 0.2...5 °C; 0.4...9 °F |
| 0.2...5 °C | 0.4...9 °F |
| Drift alarm | 0.2...5 °C; 0.4...9 °F |
| In steps of | 0.05 °C; 0.1 °F |
| 0.05 °C | 0.1 °F |
| Resolution of analogue output[K] [K] | 0.05 |
Accuracy / deviations
| Precision analogue output[K] [K] | ± 0,2 (-10...130°C); ± 0,3 (130...140°C); ± 0,3 ± 0,1% MS (-25...-10/140...160°C); (probe completely inserted into the measured medium up to the sealing chamfer) |
| Temperature coefficient[% of the span / 10 K] [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) |
Response times
| Dynamic response T05 / T09[s] [s] | 3 / 6 |
Software / programming
| Parameter setting options | drift warning/drift alarm threshold; Fail-Safe; Display unit; scaling of the analogue output; redundancy switching; performance diagnostic output; switching logic; normally open / normally closed |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM1 (4,8 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 1 |
| Min. process cycle time[ms] [ms] | 33.6 |
| Supported DeviceIDs | default; 558 |
| default | 558 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Storage temperature[°C] [°C] | -40...85 |
| Protection | IP 68; IP 69K |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 68000-2-27; 50 g (11 ms) |
| DIN EN 68000-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 20 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 213 |
| Note on approval | Including free 5-point calibration certificate. |
Mechanical data
| Weight[g] [g] | 402.5 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 50.4 / L = 173.5 |
| Materials | stainless steel (316L/1.4435); stainless steel (316L/1.4404); PEI; FKM |
| Materials (wetted parts) | stainless steel (316L/1.4435); stainless steel (316L/1.4404) |
| Process connection | threaded connection G 1 external thread Aseptoflex Vario |
| Surface characteristics Ra/Rz of the wetted parts | Ra < 0.6 µm |
| Probe diameter[mm] [mm] | 10 |
| Installation length EL[mm] [mm] | 50 |
Remarks
| Remarks | MS = set measuring span |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |