IFM TA2303
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Compact transmitters for industrial use |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can TA2303 be shipped?
TA2303 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up TA2303 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for TA2303 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for TA2303, subject to availability and destination.
High precision across the entire temperature measurement range Particularly good response dynamics and very short power-on delay time Robust stainless steel housing with very high pressure rating High protection rating for the requirements of harsh industrial environments Precise analogue output and user-friendly communication via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range[°F] [°F] | -58...302 |
| Communication interface | IO-Link |
| Process connection | threaded connection 1/2" NPT external thread |
| Installation length EL[mm] [mm] | 30 |
Application
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) |
| Media | liquids and gases |
| Pressure rating | 400 bar; 40 MPa |
| 400 bar | 40 MPa |
| Note on pressure rating | sensor; When mounted in adapters the specifications of the adapter data sheet apply. |
| MAWP for applications according to CRN[bar] [bar] | 350 |
Electrical data
| Operating voltage[V] [V] | 18...32 DC; ("supply class 2" to cULus) |
| Current consumption[mA] [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 1 |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | analogue signal; IO-Link; (configurable) |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 250; ((18...19 V); 19...32 V: 300 Ω) |
| Short-circuit protection | yes |
| Overload protection | yes |
Measuring/setting range
| Probe length L[mm] [mm] | 26.8 |
| Measuring range[°F] [°F] | -58...302 |
| Factory setting | 0...300 °F |
| Resolution of analogue output[K] [K] | 0.04 |
Accuracy / deviations
| Precision analogue output[K] [K] | ± 0,3 + (± 0,1 % MS) |
| Temperature coefficient[% of the span / 10 K] [% of the span / 10 K] | 0,1; (in case of deviation from the reference condition 25 ± 5 °C) |
Response times
| Dynamic response T05 / T09[s] [s] | 1 / 3 |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Process data variable |
| Min. process cycle time[ms] [ms] | 2.3 |
| Supported DeviceIDs | default; 378 |
| default | 378 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | DIN EN 61000-6-2 |
| Shock resistance | DIN IEC 68-2-27; 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 20 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 572 |
| UL approval | UL approval no.; K002 |
| UL approval no. | K002 |
Mechanical data
| Weight[g] [g] | 129.5 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 18.7 / L = 105.7 |
| Materials | stainless steel (316L/1.4404); PEI; FKM |
| Materials (wetted parts) | stainless steel (316L/1.4404) |
| Process connection | threaded connection 1/2" NPT external thread |
| Probe diameter[mm] [mm] | 6 |
| Installation length EL[mm] [mm] | 30 |
Displays / operating elements
| Display | operating status; 1 x LED, green |
| operating status | 1 x LED, green |
Remarks
| Remarks | MS = set measuring span |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |