IFM SV5614
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Vortex flow meters with display |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SV5614 be shipped?
SV5614 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SV5614 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SV5614 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SV5614, subject to availability and destination.
Reliable detection of flow and medium temperature Precise linearized analogue output Display can be rotated for optimum alignment Clearly readable colour display with red/green colour change Suitable for water, deionised water and cooling water
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 2 |
| Measuring range | 32...634 gph; 0.55...10.55 gpm |
| 32...634 gph | 0.55...10.55 gpm |
| Process connection | threaded connection 1/2" NPT internal thread DN10 |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | water; glycol solutions; coolants |
| Medium temperature[°F] [°F] | 14...194 |
| Pressure rating | 12 bar; 174 psi; 1.2 MPa |
| 12 bar | 174 psi |
| Note on pressure rating | up to 40 °C |
| MAWP for applications according to CRN[bar] [bar] | 4.8 |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
| Current consumption[mA] [mA] | < 30 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 3 |
| Measuring principle | Vortex |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Output signal | analogue signal |
| Number of analogue outputs | 2 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 32...634 gph; 0.55...10.55 gpm |
| 32...634 gph | 0.55...10.55 gpm |
| Display range | 0...760 gph; 0...12.7 gpm |
| 0...760 gph | 0...12.7 gpm |
| Resolution | 2 gph; 0.05 gpm |
| 2 gph | 0.05 gpm |
| Analogue start point ASP | 0...508 gph; 0...8.45 gpm |
| 0...508 gph | 0...8.45 gpm |
| Analogue end point AEP | 126...634 gph; 2.1...10.55 gpm |
| 126...634 gph | 2.1...10.55 gpm |
| In steps of | 2 gph; 0.05 gpm |
| Measuring dynamics | 1:20 |
| Measuring range[°F] [°F] | 14...194 |
| Display range[°F] [°F] | -22...230 |
| Resolution[°F] [°F] | 1 |
| Analogue start point[°F] [°F] | 14...158 |
| Analogue end point[°F] [°F] | 50...194 |
| In steps of[°F] [°F] | 1 |
Accuracy / deviations
| Accuracy (in the measuring range) | ± 2 % MEW; (water) |
| Repeatability | ± 0,5 % MEW |
| Accuracy[K] [K] | ± 1 |
Response times
| Response time[s] [s] | 1; (dAP = 0) |
| Damping process value dAP[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 6 |
Software / programming
| Parameter setting options | Damping for the analogue output dAA; Display unit |
Operating conditions
| Ambient temperature[°F] [°F] | 32...140 |
| Note on ambient temperature | medium temperature < 176 °F; medium temperature < 194 °F: 32...122 °F |
| Storage temperature[°F] [°F] | -4...176 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27; 5 g (11 ms) |
| DIN EN 60068-2-27 | 5 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; with water / 10...50 Hz 1 mm; with water / 50...2000 Hz 2 g |
| DIN EN 60068-2-6 | with water / 10...50 Hz 1 mm |
| MTTF[years] [years] | 342 |
| UL approval | UL approval no.; I002 |
| UL approval no. | I002 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 466 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 119 x 45 x 72 |
| Materials | stainless steel (316L/1.4404); PC; PBT+PC-GF30; PPS; TPE-U |
| Materials (wetted parts) | stainless steel (316L/1.4404); ETFE; PA 6T; PPS; FKM |
| Tightening torque[Nm] [Nm] | 30 |
| Process connection | threaded connection 1/2" NPT internal thread DN10 |
Displays / operating elements
| Display | colour display 1,44", 128 x 128 pixels; 2 x LED, yellow |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |