IFM SUH120
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Ultrasonic flow meters |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SUH120 be shipped?
SUH120 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SUH120 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SUH120 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SUH120, subject to availability and destination.
A robust, component-free measuring pipe made of stainless steel offers high media resistance and permanent ingress resistance The highly accurate inline measurement process eliminates any influence of varying wall thicknesses and pipe materials Operating status LED signals the sensor status and allows conclusions about process quality User-friendly communication and parameterisation via IO-Link
Specifications
Product characteristics
| Measuring range | 1...65 l/min; 0.06...3.9 m³/h; 16...1030 gph; 0.26...17.17 gpm |
| 1...65 l/min | 0.06...3.9 m³/h |
| Nominal diameter | DN15 (1/2“) |
| Process connection | Clamp DN15 DIN 32676 series A |
Application
| Special feature | Gold-plated contacts |
| Application | food and beverage industry |
| Media | ultra-pure water; water; hydrous media |
| Note on media | hydrous media: for media with >10 % additives, the repeatability is the only available value |
| Medium temperature[°C] [°C] | -40...125; (< 1 h: 150) |
| Min. burst pressure | 75 bar; 7.5 MPa |
| 75 bar | 7.5 MPa |
| Pressure rating | 25 bar; 2.5 MPa |
| 25 bar | 2.5 MPa |
| Note on pressure rating | take into account the pressure resistance of the bracket and the seal used for clamp connection |
| Vacuum resistance[mbar] [mbar] | -1000 |
Electrical data
| Operating voltage[V] [V] | 18...32 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 75 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 5 |
| Measuring principle | ultrasonic |
Inputs / outputs
| Total number of inputs and outputs | 2 |
Inputs
| Inputs | OUT2; counter reset |
| OUT2 | counter reset |
Outputs
| Total number of outputs | 2 |
| Output signal | OUT1; switching signal; pulse signal; diagnostic signal; totaliser switching signal; frequency signal; IO-Link; OUT2; switching signal; pulse signal; diagnostic signal; totaliser switching signal; analogue signal |
| OUT1 | switching signal; pulse signal; diagnostic signal; totaliser switching signal; frequency signal; IO-Link |
| OUT2 | switching signal; pulse signal; diagnostic signal; totaliser switching signal; analogue signal |
| Electrical design | PNP/NPN |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 500 |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 0...10000 |
Measuring/setting range
| Measuring range | -40...125 °C; -40...257 °F |
| 1...65 l/min | 0.06...3.9 m³/h |
| Resolution | 0.1 °C; 0.1 °F |
| 0.1 l/min | 0.001 m³/h |
| Note on factory setting | l/min, °C |
| Set point SP | -39.4...125 °C; -38.9...257 °F |
| 1.4...65 l/min | 0.082...3.9 m³/h |
| Reset point rP | -40...124.4 °C; -40...255.9 °F |
| 1...64.7 l/min | 0.062...3.88 m³/h |
| Analogue start point ASP | -65...52 l/min; -3.9...3.12 m³/h; -1030...824 gph; -17.17...13.74 gpm |
| -65...52 l/min | -3.9...3.12 m³/h |
| Analogue end point AEP | -52...65 l/min; -3.12...3.9 m³/h; -824...1030 gph; -13.74...17.17 gpm |
| -52...65 l/min | -3.12...3.9 m³/h |
| Low flow cut-off LFC | 1...3.2 l/min; 0.06...0.195 m³/h; 16...52 gph; 0.26...0.86 gpm |
| 1...3.2 l/min | 0.06...0.195 m³/h |
| Frequency end point, FEP | -7...125 °C; 19.4...257 °F |
| 13...65 l/min | 0.782...3.9 m³/h |
| Frequency at the end point FRP[Hz] [Hz] | 1...10000 |
| Pulse length[s] [s] | 0.002...2 |
| Pulse value | 0.1...99990000 I / 0.026...26414563.515 gal |
| -40...125 °C | -40...257 °F |
| 0.1 °C | 0.1 °F |
| -39.4...125 °C | -38.9...257 °F |
| -40...124.4 °C | -40...255.9 °F |
| Analogue start point | -40...92 °C; -40...197.6 °F |
| -40...92 °C | -40...197.6 °F |
| Analogue end point | -7...125 °C; 19.4...257 °F |
| -7...125 °C | 19.4...257 °F |
| Frequency start point, FSP | -40...92 °C; -40...197.6 °F |
Accuracy / deviations
| Accuracy (in the measuring range) | water; ± (2,0 % MW + 0,5 % MEW) |
| water | ± (2,0 % MW + 0,5 % MEW) |
| Repeatability | ± 0,2 % MEW |
| Accuracy[K] [K] | ± 2,5 (Q > 5 % MEW) |
| Temperature coefficient[% of the span / 10 K] [% of the span / 10 K] | 0,2 |
Response times
| Response time[s] [s] | < 0.3; (dAP = 0, T09) |
| Damping process value dAP[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | 5,7 / 86 |
Software / programming
| Diagnostic functions | direction of flow detection; signal quality |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1.3 |
| SDCI standard | IEC 61131-9: 2013-07 |
| Profiles | BLOB; Binary Large Object transfer; Common - I&D; Identification and Diagnosis |
| BLOB | Binary Large Object transfer |
| Common - I&D | Identification and Diagnosis |
| Required master port type | A |
| Process data analogue | 3 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 9.6 |
| IO-Link process data (cyclical) | totaliser; 32; Flow monitoring; 32; Temperature monitoring; 32; status; 4; Output 1; 1; Output 2; 1 |
| totaliser | 32 |
| Flow monitoring | 32 |
| Temperature monitoring | 32 |
| status | 4 |
| Output 1 | 1 |
| Output 2 | 1 |
| Supported DeviceIDs | default; 1907 |
| default | 1907 |
Operating conditions
| Ambient temperature[°C] [°C] | -20...60 |
| Storage temperature[°C] [°C] | -25...80 |
| Protection | IP 69; (DIN EN 60529) |
Tests / approvals
| EMC | DIN 61326-1:2021 |
| Shock resistance | DIN IEC 68-2-27; 20 g (11ms) |
| DIN IEC 68-2-27 | 20 g (11ms) |
| Vibration resistance | DIN IEC 68-2-6; 20 g (10...2000Hz) |
| DIN IEC 68-2-6 | 20 g (10...2000Hz) |
| MTTF[years] [years] | 136 |
| UL approval | UL approval no.; I039; File number UL; E174189 |
| UL approval no. | I039 |
| File number UL | E174189 |
| Pressure Equipment Directive | can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 523.1 |
| Housing | rectangular |
| Inlet pipe length | 5 x DN |
| Outlet pipe length | 1 x DN |
| Dimensions[mm] [mm] | 168 x 48 x 61.1 |
| Materials | housing: stainless steel (316L/1.4404); connector: PEI, FKM |
| Materials (wetted parts) | Pipe section: stainless steel (316L/1.4435); Process connection: stainless steel (316L/1.4404) |
| Nominal diameter | DN15 (1/2“) |
| Process connection | Clamp DN15 DIN 32676 series A |
| Process connection suitable for pipe standard | DN15 / Ø 19 mm x 1,5 mm; (DIN 11866 series A); (DIN EN 10357 series A) |
| Surface characteristics Ra/Rz of the wetted parts | Ra < 0.4 µm (16 µin); Rz = 4 µm (157 µin) |
Displays / operating elements
| Display | operating status; 1 x LED, green |
| operating status | 1 x LED, green |
Accessories
| Items supplied | package insert |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range; pulse and totaliser signal are only available for one of the two outputs; the specified surface characteristics Ra/Rz of the wetted surfaces do not apply to the weld seam. |
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x M12; coding: A; Contacts: gold-plated |