IFM SU7200
Quick facts
| Availability | Confirmed on request |
| Category | Ultrasonic flow meters |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SU7200 be shipped?
SU7200 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SU7200 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SU7200 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SU7200, subject to availability and destination.
Reliable detection of flow and medium temperature Suitable for water, oils and glycol solutions For installation in pipes With two programmable switching outputs Clearly visible 4-digit LED display
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 |
| Measuring range | 0...50 l/min; 0...13.2 gpm |
| 0...50 l/min | 0...13.2 gpm |
| Process connection | threaded connection G 3/4 external thread flat seal |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | water; glycol solutions; coolants; oils |
| Note on media | low-viscosity oils with viscosity: 7...40 mm²/s (40 °C); high-viscosity oils with viscosity: 30...68 mm²/s (40 °C) |
| Medium temperature[°C] [°C] | -10...80 |
| Pressure rating | 16 bar; 1.6 MPa |
| 16 bar | 1.6 MPa |
Electrical data
| Operating voltage[V] [V] | 19...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | 100 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 10 |
| Measuring principle | ultrasonic |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250; (per output) |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...50 l/min; 0...13.2 gpm |
| 0...50 l/min | 0...13.2 gpm |
| Display range | 0...60 l/min; 0...15.9 gpm |
| 0...60 l/min | 0...15.9 gpm |
| Resolution | 0.1 l/min; 0.02 gpm |
| 0.1 l/min | 0.02 gpm |
| Set point SP | 0.1...50 l/min; 0.04...13.22 gpm |
| 0.1...50 l/min | 0.04...13.22 gpm |
| Reset point rP | 0...49.9 l/min; 0...13.18 gpm |
| 0...49.9 l/min | 0...13.18 gpm |
| Max. flow rate[l/min] [l/min] | 60 |
| In steps of | 0.1 l/min; 0.02 gpm |
| Measuring range[°C] [°C] | -10...80 |
| Resolution[°C] [°C] | 0.2 |
| Set point SP[°C] [°C] | -9.8...80 |
| Reset point rP[°C] [°C] | -10...79.8 |
| In steps of[°C] [°C] | 0.2 |
Accuracy / deviations
| Accuracy (in the measuring range) | water: < ± (3 % MW + 0,2 % MEW); glycol (35 %), oil (viscosity 68 mm²/s at 40 °C): < ± (5 % MW + 0,5 % MEW) |
| Repeatability | 0,1 l/min (0,025 gpm) |
| Accuracy[K] [K] | 0,2 |
Response times
| Response time[s] [s] | 0.25; (dAP = 0) |
| Delay time programmable dS, dr[s] [s] | 0...50 |
| Damping process value dAP[s] [s] | 0...1 |
| Dynamic response T05 / T09[s] [s] | T09 = 70 (Q > 5 l/min); (water) |
Software / programming
| Parameter setting options | Flow monitoring; Temperature monitoring |
Operating conditions
| Ambient temperature[°C] [°C] | -10...60 |
| Storage temperature[°C] [°C] | -25...80 |
| Protection | IP 67 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5 kV |
| EN 61000-4-6 HF conducted | 10 V |
| CPA approval | model number; 001US; accuracy class; 3; maximum allowable error; -; Q (min); 0,5 m³/h; Q (t); -; Q (max); 3 m³/h |
| model number | 001US |
| accuracy class | 3 |
| maximum allowable error | - |
| Q (min) | 0,5 m³/h |
| Q (t) | - |
| Q (max) | 3 m³/h |
| Shock resistance | DIN IEC 68-2-27; 20 g (11 ms) |
| DIN IEC 68-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 5 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 246 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 1535.5 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 110 x 100 x 80.5 |
| Materials | housing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA |
| Materials (wetted parts) | Pipe section: stainless steel (316L/1.4404); Process connection sealing: NBR reinforced fibre Flat seal; FKM; PES |
| Process connection | threaded connection G 3/4 external thread flat seal |
Displays / operating elements
| Display | Display unit; 4 x LED, green (l/min, m³/h, gal/min, gal/h); Display unit; 2 x LED, yellow (°C / °F); switching status; 2 x LED, yellow; measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit |
| Display unit | l/min; m³/h; gpm; gph; °C; °F |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, 4-digit |
| programming | alphanumeric display, 4-digit |
Accessories
| Items supplied | sealings: 2, Centellen |
| Accessories (optional) | adapter for pipe: 1 x R1/2, stainless steel, E40178; adapter for pipe: 1 x 1/2" NPT, stainless steel, E40191; adapter for pipe: 1 x R1/2, brass, E40151; adapter for pipe: 1 x 1/2" NPT, brass, E40154 |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range; sealing: only with supplied Centellen seals |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |