Available on request

IFM SU2651

MPN: SU2651 · Brand: IFM
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryUltrasonic flow meters
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can SU2651 be shipped?

SU2651 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SU2651 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SU2651 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SU2651, subject to availability and destination.

Accurate flow measurement of ultrapure water, water, oils and glycol solutions A robust, component-free measuring pipe made of stainless steel offers high media resistance and permanent ingress resistance Can be used for mobile applications User-friendly communication and parameterisation via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range5...1000 l/min; 0.3...60 m³/h; 79...15850 gph; 1.32...264.18 gpm
5...1000 l/min0.3...60 m³/h
Nominal diameterDN50 (2“)
Process connectionthreaded connection 2" NPT external thread DN50

Application

Special featureGold-plated contacts
Applicationuse in mobile and industrial applications
Mediaultra-pure water; water; hydrous media; glycol solutions; oils (of high and low viscosity); coolants
Note on mediahydrous media: for media with >10 % additives, the repeatability is the only available value; low-viscosity oils with viscosity: 7...40 mm²/s (40 °C); high-viscosity oils with viscosity: 30...68 mm²/s (40 °C)
Medium temperature-40...120 °C; -40...248 °F
-40...120 °C-40...248 °F
Min. burst pressure150 bar; 15 MPa
150 bar15 MPa
Pressure rating100 bar; 10 MPa
100 bar10 MPa
Vacuum resistance[mbar] [mbar]-1000

Electrical data

Operating voltage[V] [V]8...32 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 175
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]5
Measuring principleultrasonic

Inputs / outputs

Total number of inputs and outputs2
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

InputsOUT2; counter reset
OUT2counter reset

Outputs

Total number of outputs2
Output signalOUT1; switching signal; pulse signal; diagnostic signal; totaliser switching signal; frequency signal; IO-Link; OUT2; switching signal; pulse signal; diagnostic signal; totaliser switching signal; analogue signal
OUT1switching signal; pulse signal; diagnostic signal; totaliser switching signal; frequency signal; IO-Link
OUT2switching signal; pulse signal; diagnostic signal; totaliser switching signal; analogue signal
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]0...10000
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10 / 0.5...4.5; (scalable)
Min. load resistance[Ω] [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-40...120 °C; -40...248 °F
5...1000 l/min0.3...60 m³/h
Resolution0.1 °C; 0.1 °F
0.1 l/min0.001 m³/h
Note on factory settinggpm; °F
Set point SP-40...119.4 °C; -40...247 °F
10.5...1000 l/min0.63...60 m³/h
Reset point rP-40...88 °C; -40...190.4 °F
5.3...994.8 l/min0.318...59.688 m³/h
Analogue start point ASP-1000...800 l/min; -60...48000 m³/h; -15850...12680 gph; -264.17...211.34 gpm
-1000...800 l/min-60...48000 m³/h
Analogue end point AEP-800...1000 l/min; -48...60 m³/h; -12680...15850 gph; -211.34...264.17 gpm
-800...1000 l/min-48...60 m³/h
Low flow cut-off LFC5...50 l/min; 0.3...3 m³/h; 79...793 gph; 1.32...13.21 gpm
5...50 l/min0.3...3 m³/h
Frequency end point, FEP-40...119.4 °C; -40...247 °F
200.6...1000 l/min12.037...60 m³/h
Frequency at the end point FRP[Hz] [Hz]1...10000
Pulse length[s] [s]0.002...2
Pulse value0.1...99990000 l; 0.03...26414563.515 gal
-40...120 °C-40...248 °F
0.1 °C0.1 °F
-40...119.4 °C-40...247 °F
-40...88 °C-40...190.4 °F
Analogue start point-8...120 °C; 17.6...248 °F
-8...120 °C17.6...248 °F
Analogue end point-40...88 °C; -40...190.4 °F
Frequency start point, FSP-8...120 °C; 17.6...248 °F

Accuracy / deviations

Accuracy (in the measuring range)glycol solutions (35%); ±(5,0 % MW + 0,5 % MEW); high-viscosity oils with viscosity 46mm2/s (40°C); ±(5,0 % MW + 0,5 % MEW); low-viscosity oils with viscosity 10mm2/s (40°C); ±(5,0 % MW + 0,5 % MEW); water; ± (1,0 % MW + 0,5 % MEW)
glycol solutions (35%)±(5,0 % MW + 0,5 % MEW)
high-viscosity oils with viscosity 46mm2/s (40°C)±(5,0 % MW + 0,5 % MEW)
low-viscosity oils with viscosity 10mm2/s (40°C)±(5,0 % MW + 0,5 % MEW)
water± (1,0 % MW + 0,5 % MEW)
Repeatability± 0,2 % MEW
Accuracy[K] [K]± 2,5 (Q > 5 % MEW)
Temperature coefficient[% of the span / 10 K] [% of the span / 10 K]0,2

Response times

Response time[s] [s]< 0.25; (dAP = 0, T09)
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]5,7 / 86

Software / programming

Diagnostic functionsdirection of flow detection; signal quality

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1.3
SDCI standardIEC 61131-9: 2013-07
ProfilesBLOB; Binary Large Object transfer; Common - I&D; Identification and Diagnosis
BLOBBinary Large Object transfer
Common - I&DIdentification and Diagnosis
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time[ms] [ms]9.6
IO-Link process data (cyclical)totaliser; 32; Flow monitoring; 32; Temperature monitoring; 32; status; 4; Output 1; 1; Output 2; 1
totaliser32
Flow monitoring32
Temperature monitoring32
status4
Output 11
Output 21
Supported DeviceIDsdefault; 1840
default1840

Operating conditions

Ambient temperature[°C] [°C]-25...60
Storage temperature[°C] [°C]-40...80
ProtectionIP 67; IP 69K

Tests / approvals

EMCDIN 61326-1:2021
Shock resistanceDIN IEC 68-2-27; 20 g (11ms)
DIN IEC 68-2-2720 g (11ms)
Vibration resistanceDIN IEC 68-2-6; 20 g (10...2000Hz)
DIN IEC 68-2-620 g (10...2000Hz)
MTTF[years] [years]160
UL approvalUL approval no.; I036; File number UL; E174189
UL approval no.I036
File number ULE174189
Pressure Equipment Directivecan be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]1384.5
Housingrectangular
Inlet pipe length5 x DN
Outlet pipe length1 x DN
Dimensions[mm] [mm]231.3 x 60.7 x 90.5
Materialshousing: stainless steel (316L/1.4404); connector: PEI, FKM
Materials (wetted parts)Pipe section: stainless steel (316L/1.4404)
Nominal diameterDN50 (2“)
Process connectionthreaded connection 2" NPT external thread DN50
Surface characteristics Ra/Rz of the wetted parts49.21 µin

Displays / operating elements

Displayoperating status; 1 x LED, green
operating status1 x LED, green

Accessories

Items suppliedpackage insert

Remarks

RemarksMW = measured value; MEW = Final value of the measuring range; pulse and totaliser signal are only available for one of the two outputs; the accuracy indications are adhered to over the entire application area
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote