IFM SDP110
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | All flow sensors / flow meters |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SDP110 be shipped?
SDP110 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SDP110 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SDP110 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SDP110, subject to availability and destination.
Air gap provided as absolute value Precise values at all times thanks to pressure-compensated measuring principle Enables zero gap and clogging detection Self-cleaning measuring channel even resists purge air pressure Easy teaching of thresholds with just one click Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Process connection | threaded connection G 1/4 internal thread DN8 |
| Measuring range[µm] [µm] | 0...400; (depending on the nozzle used) |
Application
| Application | for industrial applications |
| Media | compressed air |
| Medium temperature[°C] [°C] | -10...60 |
| Min. burst pressure | 64 bar; 6.4 MPa |
| 64 bar | 6.4 MPa |
| Pressure rating | 16 bar; 1.6 MPa |
| 16 bar | 1.6 MPa |
| MAWP for applications according to CRN | 16 bar; 1.6 MPa |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 80 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 1 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs
| Inputs | teach input |
Outputs
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 150; (per output) |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range[µm] [µm] | 0...400; (depending on the nozzle used) |
| Setting range[µm] [µm] | 0...500; (depending on the nozzle used) |
| Resolution[µm] [µm] | 1 |
| Set point SP[µm] [µm] | 2...500 |
| Reset point rP[µm] [µm] | 0...498 |
| Analogue start point ASP[µm] [µm] | 0...400 |
| Analogue end point AEP[µm] [µm] | 100...500 |
| In steps of[µm] [µm] | 1 |
| Measuring range | 0.8...100 l/min; 0.3...33.2 m/s; 0.05...6 m³/h |
| Setting range | 0...1000 |
| Resolution | 0.2 l/min; 0.1 m/s; 0.01 m³/h |
| Set point SP | 1.4...100 l/min; 0.5...33.2 m/s; 0.08...6 m³/h |
| Reset point rP | 0.9...99.5 l/min; 0.3...33 m/s; 0.05...5.97 m³/h |
| Analogue start point ASP | 0...80 l/min; 0...26.6 m/s; 0...4.8 m³/h |
| Analogue end point AEP | 20...100 l/min; 6.6...33.2 m/s; 1.2...6 m³/h |
| In steps of | 0.1 l/min; 0.1 m/s; 0.01 m³/h |
| Measuring range[bar] [bar] | -1...16 |
| Display range[bar] [bar] | -1...20 |
| Resolution[bar] [bar] | 0.05 |
| Set point SP[bar] [bar] | -0.92...16 |
| Reset point rP[bar] [bar] | -1...15.92 |
| Analogue start point[bar] [bar] | -1...12.8 |
| Analogue end point[bar] [bar] | 2.2...16 |
| In steps of[bar] [bar] | 0.01 |
| 0.8...100 l/min | 0.3...33.2 m/s |
| Display range | 0...120 l/min; 0...39.8 m/s; 0...7.2 m³/h |
| 0...120 l/min | 0...39.8 m/s |
| 0.2 l/min | 0.1 m/s |
| 1.4...100 l/min | 0.5...33.2 m/s |
| 0.9...99.5 l/min | 0.3...33 m/s |
| 0...80 l/min | 0...26.6 m/s |
| 20...100 l/min | 6.6...33.2 m/s |
| Low flow cut-off LFC | 0.6...1 l/min; 0.2...0.3 m/s; 0.04...0.06 m³/h |
| 0.6...1 l/min | 0.2...0.3 m/s |
| 0.1 l/min | 0.1 m/s |
Accuracy / deviations
| Accuracy (in the measuring range) | class 141: ± (2 % MW + 1 % MEW); class 344: ± (6 % MW + 1,2 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 23 °C |
| Repeatability | ± (0,8 % MW + 0,4 % MEW) |
| Repeatability[% of the final value] [% of the final value] | ± 0,2 |
| Characteristics deviation[% of the final value] [% of the final value] | < ± 0,5; (BFSL = Best Fit Straight Line) |
| Greatest TEMPCO of the span[% MEW / 10 K] [% MEW / 10 K] | ± 0,3 |
| Greatest TEMPCO of the zero point[% MEW / 10 K] [% MEW / 10 K] | ± 0,1 |
| Temperature coefficient[1/K] [1/K] | ± 0,07 % MW |
Response times
| Response time[s] [s] | 0.1; (dAP = 0) |
| Damping process value dAP[s] [s] | 0...5 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; current output; display can be rotated and switched off; Display unit; Teach function |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D; Identification and Diagnosis; Function; Measurement data, standard resolution |
| Common - I&D | Identification and Diagnosis |
| Function | Measurement data, standard resolution |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 7 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 5.9 |
| Supported DeviceIDs | default; 1333 |
| default | 1333 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | 0...60 |
| Storage temperature[°C] [°C] | -20...85 |
| Max. relative air humidity[%] [%] | 90 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 60947-5-9 |
| Vibration resistance | DIN EN 68000-2-6; 5 g (10...2000 Hz) |
| DIN EN 68000-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 167 |
| UL approval | UL approval no.; I012; File number UL; E174189 |
| UL approval no. | I012 |
| File number UL | E174189 |
| Pressure Equipment Directive | Sound engineering practice; can be used for stable gases fluid group 2 |
Mechanical data
| Weight[g] [g] | 548.2 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 182 x 45.4 x 67.8 |
| Materials | PBT+PC-GF30; PPS GF40; stainless steel (304/1.4301); stainless steel (303/1.4305); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM |
| Materials (wetted parts) | EN AW-6082 (aluminium); stainless steel (303/1.4305); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate; SINT-A51; stainless steel (304/1.4301); CW510L (brass) |
| Process connection | threaded connection G 1/4 internal thread DN8 |
Displays / operating elements
| Display | colour display 1,44", 128 x 128 pixels; 2 x LED, yellow |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range; Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.; For information about installation and operation please see the operating instructions. |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |