IFM SDG350
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Systems for the consumption measurement of compressed air & industrial gases |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SDG350 be shipped?
SDG350 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SDG350 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SDG350 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SDG350, subject to availability and destination.
Precise measurement of flow and consumption High accuracy, repeatability and measurement dynamics For detecting compressed air in industrial use With switching output, analogue output and pulse output Clearly visible 4-digit LED display Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range | 0.6...143.9 m/s; 8...2011 m³/h |
| 0.6...143.9 m/s | 8...2011 m³/h |
| Process connection | flange DN65 according to:DIN EN 10220 |
Application
| Application | for industrial applications |
| Media | compressed air |
| Medium temperature[°C] [°C] | -10...60 |
| Min. burst pressure | 64 bar; 6.4 MPa |
| 64 bar | 6.4 MPa |
| Pressure rating | 16 bar; 1.6 MPa |
| 16 bar | 1.6 MPa |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 80 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 1 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs
| Inputs | counter reset |
Outputs
| Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 150; (per output) |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Pulse output | consumed quantity meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -10...60 °C; 14...140 °F |
| 0.6...143.9 m/s | 8...2011 m³/h |
| Display range | -24...74 °C; -11.2...165.2 °F |
| 1.2...172.7 m/s | 16...2413 m³/h |
| In steps of | 0.1 °C; 0.1 °F |
| 0.1 m/s | 1 m³/h |
| Measuring range[bar] [bar] | -1...16 |
| Display range[bar] [bar] | -1...20 |
| Resolution[bar] [bar] | 0.05 |
| Set point SP[bar] [bar] | -0.92...16 |
| Reset point rP[bar] [bar] | -1...15.92 |
| Analogue start point[bar] [bar] | -1...12.8 |
| Analogue end point[bar] [bar] | 2.2...16 |
| In steps of[bar] [bar] | 0.01 |
| 0...100000000 m³ | 0...353146667.2 scf |
| Set point SP | -9.7...60 °C; 14.6...140 °F |
| 0.001...10000000 m³ | 0.05...353146667.2 scf |
| Pulse value | 0.001...10000000 m³; 0.05...353146667.2 scf |
| 0.0001 m³ | 0.005 scf |
| Pulse length[s] [s] | 0.002...2 |
| -10...60 °C | 14...140 °F |
| -24...74 °C | -11.2...165.2 °F |
| Resolution | 0.2 °C; 0.5 °F |
| 0.2 °C | 0.5 °F |
| -9.7...60 °C | 14.6...140 °F |
| Reset point rP | -10...59.7 °C; 14...139.4 °F |
| -10...59.7 °C | 14...139.4 °F |
| Analogue start point | -10...46 °C; 14...114.8 °F |
| -10...46 °C | 14...114.8 °F |
| Analogue end point | 4...60 °C; 39.2...140 °F |
| 4...60 °C | 39.2...140 °F |
| 0.1 °C | 0.1 °F |
Accuracy / deviations
| Accuracy (in the measuring range) | class 141: ± (3 % MW + 0,3 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; reference conditions: inlet pipe length >= 113 cm outlet pipe length >= 15 cm; reference temperature: 18..26 °C; standard volume flow 8...1155 m³/h; (standard volume flow DIN_ISO_2533 15 °C , 1013,25 mbar, 0 % r.H.) |
| Repeatability[% of the final value] [% of the final value] | ± 0,2 |
| Characteristics deviation[% of the final value] [% of the final value] | < ± 0,5; (BFSL = Best Fit Straight Line) |
| Greatest TEMPCO of the span[% MEW / 10 K] [% MEW / 10 K] | ± 0,3 |
| Greatest TEMPCO of the zero point[% MEW / 10 K] [% MEW / 10 K] | ± 0,1 |
| Accuracy[K] [K] | ± 0,5; (medium flow in the limit area of the flow measurement range) |
Response times
| Response time[s] [s] | 0.05 |
| Damping process value dAP[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 0,5 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Common - I&D; Identification and Diagnosis; Function; Measurement data, standard resolution |
| Common - I&D | Identification and Diagnosis |
| Function | Measurement data, standard resolution |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 8 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 7.2 |
| Supported DeviceIDs | default; 1537 |
| default | 1537 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...60 |
| Storage temperature[°C] [°C] | -20...85 |
| Max. relative air humidity[%] [%] | 90 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 60947-5-9 |
| Vibration resistance | DIN EN 68000-2-6; 5 g (10...2000 Hz) |
| DIN EN 68000-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 167 |
| Pressure Equipment Directive | Modul A; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 9630 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 148 x 125 x 186 |
| Materials | housing sensor: PBT+PC-GF30; PPS GF40; electronics fastener: stainless steel (304/1.4301); stainless steel (303/1.4305); Lock nut: stainless steel (316L/1.4404); Sealing-Display: FKM |
| Materials (wetted parts) | sensor feedthrough: stainless steel (304/1.4301), stainless steel (316L/1.4404); Sealing sensor - pipe section: FKM; sensor tip: ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate; pipe section: stainless steel (304/1.4301); flange: stainless steel (304/1.4301) |
| Process connection | flange DN65 according to:DIN EN 10220 |
Displays / operating elements
| Display | colour display 1,44", 128 x 128 pixels; 2 x LED, yellow |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range; D = inside pipe diameter; Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.; For information about installation and operation please see the operating instructions. |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |