Available on request

IFM SD6020

MPN: SD6020 · Brand: IFM
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategorySystems for the consumption measurement of compressed air & industrial gases
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can SD6020 be shipped?

SD6020 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SD6020 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SD6020 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SD6020, subject to availability and destination.

Precise measurement of flow, consumption and medium temperature High repeatability and measurement dynamics For detecting compressed air in industrial use Red/green display for clear identification of the acceptable range Display can be rotated for optimum alignment Convenient operation via buttons or parameter setting via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range4...1250 l/min; 0.3...99.8 m/s; 0.25...75 m³/h
4...1250 l/min0.3...99.8 m/s
Process connectionthreaded connection R 1/2 external thread DN15

Application

Applicationfor industrial applications
Mediacompressed air
Medium temperature[°C] [°C]-10...60
Min. burst pressure64 bar; 6.4 MPa
64 bar6.4 MPa
Pressure rating16 bar; 1.6 MPa
16 bar1.6 MPa
MAWP for applications according to CRN[bar] [bar]16

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]1

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

Inputscounter reset

Outputs

Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]150; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-10...60 °C; 14...140 °F
4...1250 l/min0.3...99.8 m/s
Display range-24...74 °C; -11.2...165.2 °F
0...1500 l/min0...119.8 m/s
Resolution0.2 °C; 0.5 °F
1 l/min0.1 m/s
Set point SP-9.7...60 °C; 14.6...140 °F
11...1250 l/min0.9...99.8 m/s
Reset point rP-10...59.7 °C; 14...139.4 °F
5...1243 l/min0.4...99.3 m/s
Analogue start point ASP0...1000 l/min; 0...79.8 m/s; 0...60 m³/h
0...1000 l/min0...79.8 m/s
Analogue end point AEP250...1250 l/min; 20...99.8 m/s; 15...75 m³/h
250...1250 l/min20...99.8 m/s
Low flow cut-off LFC1...13 l/min; 0.1...1.1 m/s; 0.09...0.8 m³/h
1...13 l/min0.1...1.1 m/s
In steps of0.1 °C; 0.1 °F
0...100000000 m³0...353146667.2 scf
0.001...10000000 m³0.05...353146667.2 scf
Pulse value0.001...10000000 m³; 0.05...353146667.2 scf
0.0001 m³0.005 scf
Pulse length[s] [s]0.002...2
-10...60 °C14...140 °F
-24...74 °C-11.2...165.2 °F
0.2 °C0.5 °F
-9.7...60 °C14.6...140 °F
-10...59.7 °C14...139.4 °F
Analogue start point-10...46 °C; 14...114.8 °F
-10...46 °C14...114.8 °F
Analogue end point4...60 °C; 39.2...140 °F
4...60 °C39.2...140 °F
0.1 °C0.1 °F

Accuracy / deviations

Temperature coefficient[1/K] [1/K]± 0,07 % MW
Accuracy (in the measuring range)± (15 % MW + 1,5 % MEW); (maximum value to be achieved for air quality class 344 (DIN8573-1:2010); when using pipes of tolerance class T3/T4; inlet and outlet pipe lengths without edges and abrupt diameter changes; inner surface of the pipe free of burrs)
Repeatability± 1,5 % MW
Accuracy[K] [K]± 0,5; (medium flow in the limit area of the flow measurement range)

Response times

Response time[s] [s]0.1; (dAP = 0)
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]T09 = 0,5

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesCommon - I&D; Identification and Diagnosis; Function; Measurement data, standard resolution
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, standard resolution
SIO modeyes
Required master port typeA
Process data analogue6
Process data binary2
Min. process cycle time[ms] [ms]5.9
Supported DeviceIDsdefault; 1001
default1001

Operating conditions

Ambient temperature[°C] [°C]0...60
Storage temperature[°C] [°C]-20...85
Max. relative air humidity[%] [%]90
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 60947-5-9
CPA approvalmodel number; 004TG; accuracy class; -; maximum allowable error; ± 16,5 % FS; Q (min); 0,25 m³/h; Q (t); -; Q (max); 75 m³/h
model number004TG
accuracy class-
maximum allowable error± 16,5 % FS
Q (min)0,25 m³/h
Q (t)-
Q (max)75 m³/h
Vibration resistanceDIN EN 68000-2-6; 5 g (10...2000 Hz)
DIN EN 68000-2-65 g (10...2000 Hz)
MTTF[years] [years]195
UL approvalUL approval no.; I012; File number UL; E174189
UL approval no.I012
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for stable gases fluid group 2

Mechanical data

Weight[g] [g]546.5
Housingrectangular
Dimensions[mm] [mm]150 x 45.4 x 71.2
MaterialsPBT+PC-GF30; PPS GF40; stainless steel (304/1.4301); stainless steel (303/1.4305); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM
Materials (wetted parts)stainless steel (304/1.4301); stainless steel (303/1.4305); FKM; ceramics glass passivated; PPS GF40; acrylate
Process connectionthreaded connection R 1/2 external thread DN15

Displays / operating elements

Displaycolour display 1,44", 128 x 128 pixels; 2 x LED, yellow

Remarks

RemarksMW = measured value; MEW = Final value of the measuring range; Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.; For information about installation and operation please see the operating instructions.
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote